22 February 2023 in IEEE Transactions on Industrial Electronics
We developed a magnetic navigation system (MNS) composed of a magnetic field control part and a robot arm part to precisely control the position and posture of a capsule endoscope (CE). The magnetic field control part generates a magnetic field by controlling the magnetization directions of dual permanent magnets (PMs) using motors, and the robot arm part supports and freely moves the magnetic field control part in three dimensions. First, we calculated the magnetic field generated by the dual PMs of the MNS by utilizing point-dipole approximation, and the magnetic force between the PMs of the MNS and the CE. We set up an optimal design problem to determine the rotational angles of the magnetization direction of the dual PMs of the MNS to align the CE to the given direction. We validated the proposed optimal design problem by utilizing finite element analysis. By using the developed MNS and a commercial CE, we measured the magnetic force acting on the CE and compared it with the simulated results of the finite element analysis. Finally, we performed a gastric endoscopy in a mimetic stomach and confirmed that the proposed MNS can effectively examine the major parts of a stomach.
11 March 2024 in IEEE/ASME Transactions on Mechatronics
Magnetic milli/microrobots and magnetic navigation systems have been widely investigated for medical applications due to their advantages of generating torque and force remotely and the simple mechanical structure of magnetic robots. However, there are very few cases that have been commercialized because of the limitations of conventional magnetic navigation systems (e.g., heavy weight, bulky structures, and limited compatibility with other medical devices). In this article, we propose a novel concept of a robotically adjustable magnetic navigation (RAMAN) system, which can adjust the size and position of its workspace using a robotic stage. We developed the concept and structure of the system to overcome the conventional limitations and then developed an optimization method to maximize the magnetic performance of the system. Several experiments were conducted to evaluate the performance of the RAMAN system and verify the control methods. According to the results, the RAMAN system, weight of just 910 kg, can generate a magnetic field within its workspace from 13.5 to 120 mT and adjust the height of the workspace from 200 to 400 mm. Finally, the effectiveness of the system was validated by manipulating the tethered magnetic robot in a planar open space and an artificial vascular environment.