Sandra Diaz

Sandra Diaz

Auto-generated profile, based on publicly available information

Sandra Diaz

Department of Paediatric Radiology Karolinska University Hospital Stockholm Sweden

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Ana Luiza Dallora MoraesAna Luiza Dallora Moraes
Ana Luiza Dallora Moraes
Peter AnderbergPeter Anderberg
Peter Anderberg
OKOla Kvist
Ola Kvist
EMEmilia Mendes
Emilia Mendes
SRSandra Diaz Ruiz
Sandra Diaz Ruiz
JBJohan Sanmartin Berglund
Johan Sanmartin Berglund
The assessment of bone age and skeletal maturity and its comparison to chronological age is an important task in the medical environment for the diagnosis of pediatric endocrinology, orthodontics and orthopedic disorders, and legal environment in what concerns if an individual is a minor or not when there is a lack of documents. Being a time-consuming activity that can be prone to inter- and intra-rater variability, the use of methods which can automate it, like Machine Learning techniques, is of value. The goal of this paper is to present the state of the art evidence, trends and gaps in the research related to bone age assessment studies that make use of Machine Learning techniques. A systematic literature review was carried out, starting with the writing of the protocol, followed by searches on three databases: Pubmed, Scopus and Web of Science to identify the relevant evidence related to bone age assessment using Machine Learning techniques. One round of backward snowballing was performed to find additional studies. A quality assessment was performed on the selected studies to check for bias and low quality studies, which were removed. Data was extracted from the included studies to build summary tables. Lastly, a meta-analysis was performed on the performances of the selected studies. 26 studies constituted the final set of included studies. Most of them proposed automatic systems for bone age assessment and investigated methods for bone age assessment based on hand and wrist radiographs. The samples used in the studies were mostly comprehensive or bordered the age of 18, and the data origin was in most of cases from United States and West Europe. Few studies explored ethnic differences. There is a clear focus of the research on bone age assessment methods based on radiographs whilst other types of medical imaging without radiation exposure (e.g. magnetic resonance imaging) are not much explored in the literature. Also, socioeconomic and other aspects that could influence in bone age were not addressed in the literature. Finally, studies that make use of more than one region of interest for bone age assessment are scarce.

14 March 2008 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
SDSandra Diaz
Sandra Diaz
ICIngrid Casselbrant
Ingrid Casselbrant
EPEeva Piitulainen
Eeva Piitulainen
GPGoran Pettersson
Goran Pettersson
PMPeter Magnusson
Peter Magnusson
PAPer Akeson
Per Akeson
Purpose: To measure the apparent diffusion coefficient (ADC) of hyperpolarized (HP) 3He gas using diffusion weighted MRI in healthy volunteers and patients with emphysema and examine the reproducibility and volume dependency.Materials and Methods: A total of eight healthy volunteers and 16 patients with emphysema were examined after inhalation of HP 3He gas mixed with nitrogen (N2) during breathhold starting from functional residual capacity (FRC) in supine position. Coronal diffusion‐sensitized MR images were acquired. Each subject was imaged on three separate days over a seven‐day period and received two different volumes (6% and 15% of total lung capacity [TLC]) of HP 3He each day. ADC maps and histograms were calculated. The mean and standard deviation (SD) of the ADC at different days and volumes were compared.Results: The reproducibility of the mean ADC and SD over several days was good in both healthy volunteers and patients (SD range of 0.003–0.013 cm2/second and 0.001–0.009 cm2/second at 6% and 15% of TLC for healthy volunteers, and a SD range of 0.001–0.041 cm2/second and 0.001–0.011 cm2/second, respectively, for patients). A minor but significant increase in mean ADC with increased inhaled gas volume was observed in both groups.Conclusion: Mean ADC and SD of HP 3He MRI is reproducible and discriminates well between healthy controls and patients with emphysema at the higher gas volume. This method is robust and may be useful to gain new insights into the pathophysiology and course of emphysema. J. Magn. Reson. Imaging 2008.

1 August 2009 in European Journal of Radiology
Verified
Journal Article
Closed access
SDSandra Diaz
Sandra Diaz
ICIngrid Casselbrant
Ingrid Casselbrant
EPEeva Piitulainen
Eeva Piitulainen
PMPeter Magnusson
Peter Magnusson
BPBarry Peterson
Barry Peterson
PAPer Akeson
Per Akeson

12 October 2020 in Acta Paediatrica
Verified
Journal Article
Open access
PDF file
OKOla F T Kvist
Ola F T Kvist
Ana Luiza Dallora MoraesAna Luiza Dallora Moraes
Ana Luiza Dallora Moraes
ONOla Nilsson
Ola Nilsson
Peter AnderbergPeter Anderberg
Peter Anderberg
JBJohan Sanmartin Berglund
Johan Sanmartin Berglund
SDSandra Diaz
Sandra Diaz
Aim: To assess growth plate fusion by magnetic resonance imaging (MRI) and evaluate the correlation with sex, age, pubertal development, physical activity and BMI.Methods: Wrist, knee and ankle of 958 healthy subjects aged 14.0‐21.5 years old were examined using MRI and graded by two radiologists. Correlations of growth plate fusion score with age, pubertal development, physical activity and BMI were assessed.Results: Complete growth plate fusion occurred in 75%, 85%, 97%, 98%, 98% and 90%, 97%, 95%, 97%, 98% (radius, femur, proximal‐ and distal tibia and calcaneus) in 17‐year‐old females and 19‐year‐old males, respectively. Complete fusion occurs approximately 2 years earlier in girls than in boys. Pubertal development correlated with growth plate fusion score (ρ = 0.514‐0.598 for the different growth plate sites) but regular physical activity did not. BMI also correlated with growth plate fusion (ρ = 0.186‐0.384). Stratified logistic regression showed increased odds ratio (OR F: 2.65‐8.71; M: 1.71‐4.03) for growth plate fusion of obese or overweight subects versus normal‐weight subjects. Inter‐observer agreement was high (Κ = 0.87‐0.94).Conclusion: Growth plate fusion can be assessed by MRI; occurs in an ascending order, from the foot to the wrist; and is significantly influenced by sex, pubertal development and BMI, but not by physical activity.

5 December 2019 in JMIR Medical Informatics
Verified
Journal Article
Open access
Ana Luiza Dallora MoraesAna Luiza Dallora Moraes
Ana Luiza Dallora Moraes
JBJohan Sanmartin Berglund
Johan Sanmartin Berglund
MBMartin Brogren
Martin Brogren
OKOla Kvist
Ola Kvist
SRSandra Diaz Ruiz
Sandra Diaz Ruiz
Peter AnderbergPeter Anderberg
Peter Anderberg
Background: Bone age assessment (BAA) is an important tool for diagnosis and in determining the time of treatment in a number of pediatric clinical scenarios, as well as in legal settings where it is used to estimate the chronological age of an individual where valid documents are lacking. Traditional methods for BAA suffer from drawbacks, such as exposing juveniles to radiation, intra- and interrater variability, and the time spent on the assessment. The employment of automated methods such as deep learning and the use of magnetic resonance imaging (MRI) can address these drawbacks and improve the assessment of age. Objective: The aim of this paper is to propose an automated approach for age assessment of youth and young adults in the age range when the length growth ceases and growth zones are closed (14-21 years of age) by employing deep learning using MRI of the knee. Methods: This study carried out MRI examinations of the knee of 402 volunteer subjects—221 males (55.0%) and 181 (45.0%) females—aged 14-21 years. The method comprised two convolutional neural network (CNN) models: the first one selected the most informative images of an MRI sequence, concerning age-assessment purposes; these were then used in the second module, which was responsible for the age estimation. Different CNN architectures were tested, both training from scratch and employing transfer learning. Results: The CNN architecture that provided the best results was GoogLeNet pretrained on the ImageNet database. The proposed method was able to assess the age of male subjects in the range of 14-20.5 years, with a mean absolute error (MAE) of 0.793 years, and of female subjects in the range of 14-19.5 years, with an MAE of 0.988 years. Regarding the classification of minors—with the threshold of 18 years of age—an accuracy of 98.1% for male subjects and 95.0% for female subjects was achieved. Conclusions: The proposed method was able to assess the age of youth and young adults from 14 to 20.5 years of age for male subjects and 14 to 19.5 years of age for female subjects in a fully automated manner, without the use of ionizing radiation, addressing the drawbacks of traditional methods.

9 March 2020 in Emergency Radiology
Verified
Journal Article
Open access
PDF file
LGLena Gordon
Lena Gordon
PNPatrik Nowik
Patrik Nowik
SKShahla Mobini Kesheh
Shahla Mobini Kesheh
MLMarika Lidegran
Marika Lidegran
SDSandra Diaz
Sandra Diaz
Purpose: Suspected airway foreign body aspiration (FBA) is a common event in paediatric emergency units, especially in children under 3 years of age. It can be a life-threatening event if not diagnosed promptly and accurately. The purpose of this study is to compare the diagnostic performance of an ultralow-dose CT (DLP of around 1 mGycm) with that of conventional radiographic methods (fluoroscopy and chest radiography of the airways) in the diagnosis of FBA children’s airways. Methods: Retrospective cross-sectional study. Data from 136 children were collected: 75 were examined with conventional radiographic methods and 61 with ultralow-dose CT. Effective doses were compared using independent t tests. The results of bronchoscopy, if performed, were used in creating contingency 2 × 2 tables to assess the diagnostic performance between modalities. An extra triple reading of all images was applied for this purpose. Results: The effective doses used in the ultralow-dose CT examinations were lower compared with those in conventional methods (p < 0.001). The median dose for CT was 0.04 mSv compared with 0.1 mSv for conventional methods. Sensitivity and specificity were higher for ultralow-dose CT than those for conventional methods (100% and 98% versus 33% and 96%) as were the positive and negative predicted values (90% and 100% versus 60% and 91%). Conclusion: Ultralow-dose CT can be used as the imaging of choice in the diagnosis of airway FBA in emergency settings, thereby avoiding concerns about radiation doses and negative bronchoscopy outcomes.