18 May 2020 in IEEE Transactions on Power Delivery
Energization of the transformer leads to large magnetizing current called as inrush current. It results in reduction in transformer life, reduction in circuit breaker life and power quality issues in the system. For low and medium voltage level systems in generation and distribution, usually gang operated circuit breakers are employed, which do not allow independent pole operation. This makes the controlled switching more challenging in such systems. This paper proposes a controlled switching technique to minimize the inrush currents for 3-phase transformer using gang operated circuit breaker. Optimum points for controlled closing and opening are obtained from a flux error function calculated from residual and prospective fluxes of the transformer. Practical challenges due to error in voltage measurements, variation in mechanical closing time, transients in flux etc. and their solutions are also discussed in this paper. The proposed technique is validated by controller hardware-in-loop (CHIL) test and a scaled-down laboratory test on 5 kVA, 210/400 V, Delta-Star transformer. In both the cases, the inrush current is limited to 1pu, demonstrating the effectiveness of the proposed scheme. Furthermore, a field test is carried out on a 500 kVA, 6.6kV/433V, Delta-Star distribution transformer to confirm viability of the developed switching technique.
29 October 2020 in IEEE Transactions on Energy Conversion
In this article, an online approach for joint parameter estimation of the exciter and Synchronous Generator (SG) is proposed. It only utilizes the Phasor Measurement Unit (PMU) based measurements, which can be obtained at the SG's terminal and does not require field measurements (as in brushless exciters). Compared to existing joint estimation approaches, the proposed work includes multiple aspects to put forward a pragmatic estimation framework. Firstly, the unobservable erroneous initial states are duly considered by utilizing the proposed Augmented Parameter Vector (APV). It is an essential feature in practical scenarios as an accurate representation of a dynamic system entails knowledge of true initial states and parameters. Secondly, suitable models of SG and exciter necessitate the inclusion of saturation characteristics, which is also considered in present work. Further, the estimation procedure is independent of multiple pre-tuned parameters, as such dependence may lead to tedious implementation and inaccurate estimates. Additionally, Wavelet denoising is used to improve the parameter estimation accuracy by pre-processing the noisy measurements prior to estimation. Real-Time Digital Simulator (RTDS) based simulation results, considering noise and measurement rate analogous to commercial synchrophasors, demonstrate the proposed approach's improved accuracy.
4 May 2020 in IEEE Transactions on Power Systems
This paper presents a clustering technique to rank the dominant modes of low frequency oscillations in power systems under model order uncertainty of the signal. The rotational invariance property of the signal subspace is utilized to obtain the modes of oscillations. Rotational invariance of the signal under multiple shifts is considered to obtain the preliminary estimates of the modes. Subsequently, the modes are clustered to obtain the dominant modes that belong to the signal subspace. A signal subspace participation index (SSPI) is used to rank the modes according to their dominance in signal subspace. Thereafter, the convex combination of the preliminary modes, estimated from the multiple shifts of the signal subspace, is used to obtain the final mode estimates. The simulation results are presented for signal generated using the modes obtained from a two-area system. Additionally, the methodology is also tested on field data obtained from the PMU installed at a generating station in India.
3 October 2022 in Journal of Nondestructive Evaluation