Seung Bae Lee

Seung Bae Lee

Auto-generated profile, based on publicly available information

Seung Bae Lee

Department of Urology, Sheikh Khalifa Specialty Hospital, Ras Al Khaimah, United Arab Emirates

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

26 March 2022 in Computers in Biology and Medicine
Verified
Journal Article
Open access
KKKyungwuk Kim
Kyungwuk Kim
SPSe-Hyun Park
Se-Hyun Park
GIGyeongtae Im
Gyeongtae Im
SLSeung Bae Lee
Seung Bae Lee
YBYasutaka Baba
Yasutaka Baba
HKHyoung-Ho Kim
Hyoung-Ho Kim
This study investigates the effects of vesicoureteral reflux (VUR) in the upper and lower urinary tracts with and without ureteral stenosis and with a double J stent (DJS). The entire length of the urinary tract with an implanted DJS was modeled. To assess the possibility of VUR, the measured values were used as boundary conditions for the baseline, the maximum cystometric bladder capacity (MCBC) during the filling phase, and maximum vesical pressure during the voiding phase were computed. The flow rates, flow patterns, wall shear stress (WSS) distribution, impact force induced by reflux urination, and helicity of the bladder were investigated for the urinary system. The flow from the bladder to the renal pelvis was detected at maximum vesical pressure (75 cmH2O) during the voiding phase, and a small amount (1.09 mL/s) of VUR was noted at the MCBC during the filling phase. The WSS increased when the reflux was large. Helicity within the bladder varied with the stenosis as well as opening and closing of the urethra. The reflux within the stent was reduced by 40% by inserting a ball into the stent. The main VUR factor was the opening and closing of the vesicoureteric junction by the detrusor muscle. The largest urine reflux (11.7 mL/s) to the kidney occurred when the detrusor muscle was relaxed. Ureteral stenosis affected the VUR and reduced urine reflux. Ball insertion in the stent reduced urine reflux through the stent lumen.

19 July 2022 in Prostate International
Verified
Journal Article
Open access
SHSung Kyu Hong
Sung Kyu Hong
SSSang Hun Song
Sang Hun Song
HKHak Ju Kim
Hak Ju Kim
HLHae Sung Lee
Hae Sung Lee
JNJun Hyun Nam
Jun Hyun Nam
SLSeung Bae Lee
Seung Bae Lee
To assess temporal improvement of prostate image reporting and data system (PIRADS) 3-5 lesion correlation to histopathologic findings from radical prostatectomy (RP) in prostate cancer (PCa). A total of 1481 patients who underwent RP for biopsy-proven PCa between 2015 and 2019 were divided into 14 groups of 100 sequential readings for the evaluation of histopathological correlation with PIRADS readings. Temporal trends of PIRADS distribution and predictive performance for RP pathology were evaluated to assess underlying changes in prostate magnetic resonance imaging (MRI) interpretation by radiologists. PIRADS 4-5 lesions were significantly correlated with the increasing rates of Gleason Group (GG) upgrade (p = 0.044) and decreasing rate of GG downgrade (p = 0.016) over time. PIRADS ≥3 lesions read after median 2 years of experience were shown to independently predict intermediate–high-risk (GG ≥ 3) PCa (odds ratio 2.93, 95% confidence interval 1.00–8.54; P= 0.049) in RP pathology. Preoperative GG ≥ 3 biopsy lesions with PIRADS 4-5 lesions were significantly more susceptible to GG upgrade (P= 0.035) and GG ≥ 4 RP pathology (p = 0.003) in experienced reads, in contrast to insignificant findings in early readings (p = 0.588 and 0.248, respectively). Preoperative MRI reports matched with RP pathology suggest an improved prediction of adverse pathology in PIRADS 3-5 lesions over time, suggesting a temporal change in PIRADS interpretation and predictive accuracy. Institutions with low volume experience should use caution in solely relying on MRI for predicting tumor characteristics. Future prospective trials and larger scale assessments are required to further validate our results.

23 June 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HKHyoung-Ho Kim
Hyoung-Ho Kim
KKKyungwuk Kim
Kyungwuk Kim
YCYoung Ho Choi
Young Ho Choi
SLSeung Bae Lee
Seung Bae Lee
YBYasutaka Baba
Yasutaka Baba
This study investigated which sizes of double-J stents are more effective in achieving an acceptable urine flow through stenotic and stented ureters. Sixty four computational fluid dynamics models of the combinations of two different gauge ureters (4.57 mm and 5.39 mm in diameter) with four different levels of ureteral and four different sizes of double-J stents were developed for the numerical analysis of urine flow in the ureter. Luminal, extraluminal, and total flow rates along the ureter were measured, and the flow patterns around the ports and side holes were investigated. For the 4.57-mm ureter, the total flow rate for each gauge of stent was 23–63 mL/h (5 Fr), 20–47 mL/h (6 Fr), 17–35 mL/h (7 Fr), and 16–26 mL/h (8 Fr) and for the 5.39-mm ureter, the total flow rate for each gauge of stent was 43–147 mL/h (5 Fr), 36–116 mL/h (6 Fr), 29–92 mL/h (7 Fr), and 26–71 mL/h (8 Fr). With a 74% stenosis, all stents allowed a low flow rate, and the differences in flow rates between the stents were small. At the other levels of stenosis, 5 Fr stents allowed greater flow rates than the 8 Fr stents. The luminal flow rate increased just before the area of stenosis and decreased after the stenosis because of the increase and decrease in the luminal flow through the side holes before and after the stenosis. Therefore, a larger double-J stent is not favorable in achieving an acceptable urine flow through the stenotic and stented ureters. The results in this study could not be necessarily correlated with clinical situation because peristalsis, viscosity of the urine and real format of the ureter were not considered in our model. In vivo experiments are necessary for confirmation of our findings. Double J stents are commonly used in the ureteral stenosis or occlusion, especially due to ureter stones which obstruct the flow of urine. Clinicians choose the size of double J stent on the basis of their clinical experience. Here, we tried to know which sizes of double J stents are better for sufficient urine flow. According to various documents that try to determine the optimal shape of double J stents to increase the urine flow through the ureter, mostly bigger stent is recommended to occur maximum urine flow. However, in case of ureter with stenosis or occlusion, the right size of the double J stent may vary depending on the degree of stenosis in the ureter. To find appropriate stent size for the ureter with stenosis, computational fluid dynamics was conducted. This study shows that smaller diameter stents are more appropriate than larger diameter stents depending on the situation.

1 January 2014 in Korean Journal of Urology
Verified
Journal Article
Open access
PDF file
JJJae Hyun Jung
Jae Hyun Jung
SCSung Yong Cho
Sung Yong Cho
CJChang Wook Jeong
Chang Wook Jeong
HJHyeon Jeong
Hyeon Jeong
HSHwancheol Son
Hwancheol Son
SLSeung Bae Lee
Seung Bae Lee
Jung JH, et al. Korean J Urol. 2014 Jul;55(7):475-481. http://dx.doi.org/10.4111/kju.2014.55.7.475

1 September 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
MIMd. Didarul Islam
Md. Didarul Islam
JKJeong Sik Kim
Jeong Sik Kim
SJSang Jin Jeon
Sang Jin Jeon
HKHyo Jeong Kang
Hyo Jeong Kang
KKKyungwuk Kim
Kyungwuk Kim
HKHyoung-Ho Kim
Hyoung-Ho Kim
Several studies have investigated predictive factors such as morphological, physiological, and fluid dynamics perspectives for obstructive sleep apnea (OSA) using computed tomography imaging, computer simulations, and experiments. Computational fluid dynamics is used in this study to analyze airflow in the upper airway across different body mass index (BMI) groups to identify suitable factors for predicting OSA. A comparative analysis is conducted on three groups: normal BMI (22.8 ± 1.0), overweight BMI (31.8 ± 1.5), and OSA (28.6 ± 3.3), with nine participants in each group. Geometric parameters were analyzed in addition to fluid dynamics factors. A comparison of the geometric variables revealed that the OSA group had the shortest total airway length (1.5 × 10−1 m) and the smallest volume (5.4 × 10−5 m3). However, t-test results showed low statistical significance for these differences. For fluid dynamics variables, the OSA group experienced the highest pressure drop (−46.8 Pa) and the highest adjusted pressure coefficient (Cp = 0.88) compared to the other two groups. From the analysis of breathing diagrams, the OSA group exhibited the largest area under the breathing power curve (32.6 × 10−3 N m/s) followed by the normal weight (24.9 × 10−3 N m/s) and overweight (21.0 × 10−3 N m/s) groups in descending order. Analysis of fluid dynamics factors indicated that the OSA group exhibited significantly higher pressure drop and pressure coefficient values compared to other groups although the differences between the groups were less significant. Finally, one key finding from this research highlights a new computational approach that relies on the breathing diagram. This new approach could provide more accurate insights into predicting and managing OSA due to their distinctive shapes.