Joop C. Kruithof

Joop C. Kruithof

Auto-generated profile, based on publicly available information

Joop C. Kruithof

Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA Leeuwarden, The Netherlands

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2007 in Ozone: Science & Engineering
Verified
Journal Article
Closed access
JKJoop C. Kruithof
Joop C. Kruithof
PKPeer C. Kamp
Peer C. Kamp
BMBram J. Martijn
Bram J. Martijn
PWN's water treatment plant Andijk was commissioned almost 40 years ago. It services water from the IJssel Lake by conventional surface water treatment. In view of taste and odor problems the plant was retrofitted with GAC filtration 25 years ago. The finished water quality still complies with all E.C. and Dutch drinking water standards. Nevertheless an upgrade is desired to avoid the use of chlorine and to extend the barriers against pathogenic micro-organisms and a broad range of organic micropollutants such as pesticides, rocket fuel by-products (NDMA), fuel oxygenates (MTBE), solvents (dioxane), endocrine disruptors, algae toxins, pharmaceuticals, etc. UV/H2O2 treatment was selected for both primary disinfection and organic contaminant control. The disinfection requirements were based on a 10−4 health risk. The required 3 log inactivation for Giardia and Cryptosporidium was achieved by an UV dose lower than 20 mJ/cm2. The highest UV dose, 105 mJ/cm2, was needed for the inactivation of spores of Sulphite Reducing Clostridia. Reactivation of protozoa was established for UV doses up to 25 mJ/cm2, for doses higher than 45 mJ/cm2 no reactivation was observed. In view of the raw water concentrations the required organic contaminant degradation was set at 80%. Collimated beam and pilot-plant work showed that the required degradation can be achieved by the proper combination of electric energy and H2O2. In a UV reactor optimized for organic contaminant control, UV dose of 540 mJ/cm2 (about 0.5 kWh/m3) and 6 mg/L H2O2 were needed. Under those conditions pesticides (atrazine), NDMA, MTBE, dioxane, endocrine disruptors (bisphenol A), microcystine and pharmaceuticals (diclofenac, ibuprofen) could be removed up to the required 80%. Bromate formation was absent while formation of primary metabolites was insignificant. The UV dose for organic contaminant control is about five times higher than the dose needed for disinfection. The UV/H2O2 process was implemented into the existing treatment train between the sand and GAC filters. In the GAC filters excess H2O2 is degraded, nitrite is converted into nitrate and biodegradable reaction products are consumed by bacteria. The full-scale installation with 3 streets of 4 Trojan Swift 16L30 reactors has been in operation since October 2004. Disinfection and organic contaminant control are as expected.

24 November 2010 in Ozone: Science & Engineering
Verified
Journal Article
Closed access
BMBram J. Martijn
Bram J. Martijn
AFAshlee L. Fuller
Ashlee L. Fuller
JMJames Malley
James Malley
JKJoop C. Kruithof
Joop C. Kruithof
PWN considers ion exchange and ultrafiltration (IX-UF) for replacing the existing CSF pretreatment at the Andijk water treatment plant. Advanced oxidation (UV/H2O2) in combination with granular activated carbon filtration (GAC) as a non selective barrier against organic micro pollutants is operational since 2004. Effects of an improved pretreatment on the UV/ H2O2 in terms of direct photolysis, OH-radical oxidation and energy consumption are presented in this paper. NDMA and 1,4-dioxane are selected to show the impact of pretreatment on UV photolysis and hydroxyl radical oxidation, respectively. Key water quality parameters are DOC and nitrate for scavenging and competition for UV light. Compared to CSF, the electrical energy per order (EEO) for IX-UF treated water was reduced with about 50%.

1 February 2013 in Water Supply
Verified
Journal Article
Closed access
PDF file
JKJoop C. Kruithof
Joop C. Kruithof
BMBram J. Martijn
Bram J. Martijn
The presence of pesticides, endocrine disruptors and pharmaceuticals caused PWN to implement multiple barriers for organic contaminant control in their surface water treatment plants. A combination of advanced oxidation by UV/H2O2 treatment and granular activated carbon (GAC) filtration is installed. Medium pressure UV experiments in a standard pilot reactor have been carried out into the degradation of a representative selection of pesticides found in PWN's main raw water source, the IJssel Lake. It was observed that atrazine and diuron are more sensitive to direct photodegradation while bentazone and bromacil are primarily degraded by hydroxyl radical oxidation. Addition of H2O2 increased the decay rate of all selected herbicides. Using computational fluid dynamics, irradiance distribution and kinetic models developed by Trojan Technologies Inc., an optimized UV-reactor was designed. In tests with a pilot reactor according to this new design, the predicted performance was confirmed, both for photodegradation and hydroxyl radical oxidation. During the research period, the scope broadened from pesticides to pharmaceuticals, endocrine disrupting compounds, solvents and algae toxins. At process conditions 0.56 kWh/m3 and 6 mg/L H2O2, 80–100% degradation was achieved for compounds such as mecoprop, clofibric acid and diclofenac. A somewhat lower degradation was found for dicamba, 2, 4-D, bentazone, ibuprofen, carbamazepine and sulphametoxalol. The developed modelling was used to design a full scale UV/H2O2 system with an electric energy of 0.56 kWh/m3 for treatment of 3,000 m3/h. In a site acceptance test, degradation of atrazine was measured at two UV-doses at a fixed H2O2 dose of 6 mg/L. The installation performed as predicted by the design models and design criteria were met. At wtp Andijk, UV/H2O2 is integrated in the existing process train, preceded by conventional surface water treatment (coagulation, sedimentation and filtration) and followed by GAC filtration providing a robust barrier against reaction products from both oxidation and photolytic degradation (assimilable organic carbon, nitrite). Replacing the conventional pretreatment by ion exchange followed by ceramic microfiltration will further improve the economics of UV/H2O2 treatment.

12 May 2016 in Desalination and Water Treatment
Verified
Journal Article
Open access
HBHohee Bang
Hohee Bang
YSYness M. Slokar
Yness M. Slokar
Giuliana FerreroGiuliana Ferrero
Giuliana Ferrero
JKJoop C. Kruithof
Joop C. Kruithof
MKMaria D. Kennedy
Maria D. Kennedy
The occurrence of taste and odor in drinking water is the most common cause of consumer complaints. In this study, the effect of water matrix constituents (i.e. TOC, alkalinity, and ) on the removal of geosmin/2-MIB with UV/H2O2 treatment was assessed. Experiments were carried out with a collimated beam apparatus equipped with a low and a medium-pressure (MP) UV lamp, with UV doses ranging from 300 to 1,200 mJ/cm2 with and without the addition of 4 mg/L H2O2. Results showed that the removal efficiency of geosmin/2-MIB with low pressure UV/H2O2 was inversely proportional to both the concentration of TOC and alkalinity in the synthetic water, as both parameters acted as scavengers of OH radicals. In the case of geosmin, the addition of 0.8 mg C/L of fulvic acid decreased the removal efficiency by 30%. The application of MPUV/H2O2 to water containing resulted in formation of which is also a OH radical scavenger. The presence of scavengers, in particular natural organic matter, causes significant increase in energy requirement due to the strong absorption properties for UV light and high reactivity with OH radicals.

26 November 2021 in Membranes
Verified
Journal Article
Open access
PDF file
LJLuisa Javier
Luisa Javier
LBLaura Milena Pulido Beltran
Laura Milena Pulido Beltran
JKJoop Kruithof
Joop Kruithof
JVJohannes Simon Vrouwenvelder
Johannes Simon Vrouwenvelder
NFNadia Farhat
Nadia Farhat
Biofouling is a problem that hinders sustainable membrane-based desalination and the stratification of bacterial populations over the biofilm’s height is suggested to compromise the efficiency of cleaning strategies. Some studies reported a base biofilm layer attached to the membrane that is harder to remove. Previous research suggested limiting the concentration of phosphorus in the feed water as a biofouling control strategy. However, the existence of bacterial communities growing under phosphorus-limiting conditions and communities remaining after cleaning is unknown. This study analyzes the bacterial communities developed in biofilms grown in membrane fouling simulators (MFSs) supplied with water with three dosed phosphorus conditions at a constant biodegradable carbon concentration. After biofilm development, biofilm was removed using forward flushing (an easy-to-implement and environmentally friendly method) by increasing the crossflow velocity for one hour. We demonstrate that small changes in phosphorus concentration in the feed water led to (i) different microbial compositions and (ii) different bacterial-cells-to-EPS ratios, while (iii) similar bacterial biofilm populations remained after forward flushing, suggesting a homogenous bacterial community composition along the biofilm height. This study represents an exciting advance towards greener desalination by applying non-expensive physical cleaning methods while manipulating feed water nutrient conditions to prolong membrane system performance and enhance membrane cleanability.

1 July 2007 in Water Practice
Verified
Journal Article
Closed access
BMBram J. Martijn
Bram J. Martijn
BVBram J. Van Der Veer
Bram J. Van Der Veer
JKJoop C. Kruithof
Joop C. Kruithof