18 December 2009 in Physical Review B
VNVenkatesh Narayanamurti
We conduct a comprehensive investigation into the electronic and magnetotransport properties of ZnO nanoplates grown concurrently with ZnO nanowires by the vapor-liquid-solid method. We present magnetoresistance data showing weak localization in our nanoplates and probe its dependence on temperature and carrier concentration. We measure phase coherence lengths of 50–100 nm at 1.9 K and, because we do not observe spin-orbit scattering through antilocalization, suggest that ZnO nanostructures may be promising for further spintronic study. We then proceed to study the effect of weak localization on electron mobility using four-terminal van der Pauw resistivity and Hall measurements versus temperature and carrier concentration. We report an electron mobility of at 275 K, comparable to what is observed in ZnO thin films. We compare Hall mobility to field-effect mobility, which is more commonly reported in studies on ZnO nanowires and find that field-effect mobility tends to overestimate Hall mobility by a factor of 2 in our devices. Finally, we comment on temperature-dependent hysteresis observed during transconductance measurements and its relationship to mobile, positively charged Zn interstitial impurities.
11 October 2005 in The Journal of Physical Chemistry B
8 September 2009 in Nanotechnology
VNVenkatesh Narayanamurti
We present a general approach to growing ZnO nanowires on arbitrary, high melting point (above 970 degrees C) substrates using the vapor-liquid-solid (VLS) growth mechanism. Our approach utilizes the melting point reduction of sufficiently small (5 nm diameter) Au particles to provide a liquid catalyst without substrate interaction. Using this size-dependent melting effect, we demonstrate catalytic VLS growth of ZnO nanowires on both Ti and Mo foil substrates with aspect ratios in excess of 1000:1. Transmission electron microscopy shows the nanowires to be single-crystalline, and photoluminescence spectra show high-quality optical properties. We believe this growth technique to be widely applicable to a variety of substrates and material systems.
17 June 2006 in Analytical Chemistry
2 February 2024 in Physics in Medicine & Biology
Objective. Inter-crystal scattering (ICS) in light-sharing positron emission tomography (PET) detectors leads to ambiguity in positioning the initial interaction, which significantly degrades the contrast, quantitative accuracy, and spatial resolution of the resulting image. Here, we attempt to resolve the positioning ambiguity of ICS in a light-sharing depth-encoding detector by exploiting the confined, deterministic light-sharing enabled by the segmented light guide unique to Prism-PET. Approach. We first considered a test case of ICS between two adjacent crystals using an analytical and a neural network approach. The analytical approach used a Bayesian estimation framework constructed from a scatter absorption model—the prior—and a detector response model—the likelihood. A simple neural network was generated for the same scenario, to provide mutual validation for the findings. Finally, we generalized the solution to three-dimensional event positioning that handles all events in the photopeak using a convolutional neural network with unique architecture that separately predicts the identity and depth-of-interaction (DOI) of the crystal containing the first interaction. Main results. The analytical Bayesian method generated an estimation error of 20.5 keV in energy and 3.1 mm in DOI. Further analysis showed that the detector response model was sufficiently robust to achieve adequate performance via maximum likelihood estimation (MLE), without prior information. We then found convergent results using a simple neural network. In the generalized solution using a convolutional neural network, we found crystal identification accuracy of 83% and DOI estimation error of 3.0 mm across all events. Applying this positioning algorithm to simulated data, we demonstrated significant improvements in image quality over the baseline, centroid-based positioning approach, attaining 38.9% improvement in intrinsic spatial resolution and enhanced clarity in hot spots of diameters 0.8 to 2.5 mm. Significance. The accuracy of our findings exceeds those of previous reports in the literature. The Prism-PET light guide, mediating confined and deterministic light-sharing, plays a key role in ICS recovery, as its mathematical embodiment—the detector response model—was the essential driver of accuracy in our results.