21 October 2022 in IEEE Open Access Journal of Power and Energy
The extent of the damage to Puerto Rico from Hurricane Maria in September 2017 led to outages in electricity service that persisted for months. Power system operators attempting to restore critical facilities faced challenges on almost every front, from supply chain interruptions to the inaccessibility of key assets. After a disaster of this magnitude, it is critical, but challenging, to prioritize how limited resources are directed toward rebuilding and fortifying the electric power system. To inform these decisions, the U.S. Department of Energy funded efforts investigating methodologies to identify critical vulnerabilities to the Puerto Rican power system, and to provide data-driven recommendations on how to harden and operate the system for greater resilience. This work presents the Risk-based Contingency Analysis Tool (RCAT), a framework developed as a part of that resilience initiative. The framework can qualitatively and quantitatively describe the most critical system vulnerabilities with an understanding of both likelihood of occurrence and impact. It evaluates the effectiveness of candidate remediation strategies in reducing overall risk to the system from future hurricane events. This paper will describe RCAT, with an emphasis on how different modeling capabilities have been integrated along with probabilistic methods and analytical metrics to better describe risk.
1 September 2021 in Sustainable Energy, Grids and Networks
5 November 2021 in IEEE Access
Research on demand response and transactive energy systems often require granular, appliance-level demand data. However, there is no existing test system with such appliance-level data with proper temporospatial diversity in a realistic distribution system. This paper develops a 240-node real distribution test system with appliance-level demand data for responsive loads. The residential appliance-level demand data are derived from smart meters connected to 1,120 homes in a real distribution system from Iowa State, hereafter called Midwest 240-Node test distribution system. A queueing load model was used to derive the appliance-level data from the smart meter data. The Midwest 240-Node test distribution system provides granular appliance-level information for all homes in the distribution system (i.e., individual appliances that constitute the home load), and the aggregate of all customer load emulates the actual smart meter data. The performance of the Midwest 240-Node test distribution system is evaluated by comparing the aggregated appliance-level demand with the actual measured smart meter data from the utility. The one-year appliance data has a mean absolute percentage error of 2.58% compared to the measured smart meter data. The test system is modeled in OpenDSS and GridLAB-D and is openly available to researchers to enable demand response and transactive energy studies with active end-users.
21 June 2023 in IEEE Access
This paper explores the potential of distributed ledger technology (DLT) to improve fault-tolerant grid operations by leveraging its core features as an immutable, decentralized ledger, a distributed, consensus-based agreement process, and a distributed state-replication engine. Distribution power systems deliver electricity to millions of customers; however, they are susceptible to various threats that can result in customer interruptions. These include faults caused by adverse weather conditions, natural disasters, vegetation growth, equipment failure, and malicious attacks. To minimize the effects of these faults, fault-handling approaches rely on network knowledge to isolate affected areas and reconnect unaffected areas, reducing the number of affected customers while maintaining safety. Here, we present a trusted data-sharing architecture that enables independent, distributed actors to reconstruct the pre-fault system state by enabling distributed resources to make appropriate decisions with limited network/system information. Although the process requires some data sharing between switch-delimited areas, the approach limits the amount of private information shared, preserving customers’ privacy and business-sensitive information. We include three use cases that form a foundation for third parties to develop functional solutions that can eventually be deployed in the field. The gross error detection method used within switch-delimited areas can identify sensor errors and accurately detect circuit breaker states. The evaluation of possible reconnection while preserving data ownership resulted in a voltage magnitude difference smaller than 0.01% from the OpenDSS power flow solution that has full system knowledge, which is below the expected power flow tolerance. The approach offers a promising opportunity for improving fault-tolerant distribution grid operations.
26 May 2025 in IEEE Access
This research article presents a comprehensive review of resilience in power transmission and distribution (T&D) systems, focusing on key studies that examine structural integrity, mechanical stress distribution, and system reliability under various conditions. The primary objective is to investigate the dynamics of adjacent spans and their role in influencing stress distribution and structural resilience of poles and towers through the cables connecting them. The article synthesizes findings across multiple studies, covering assumptions, system topologies, methodologies, and challenges that affect resilience in these networks. Particular attention is given to identifying studies that address the influence of adjacent spans and tower–line interactions, as these factors play a crucial role in the stress distribution and structural dynamics within poles, towers, and transmission lines. In addition to identifying critical factors contributing to system vulnerability, this review emphasizes the importance of continued research to better understand and mitigate risks from extreme events, such as high winds combined with ice storms, which pose significant risks to the stability and reliability of electricity supply. By consolidating knowledge on current challenges and future needs, this work outlines future directions to advance resilience studies and contributes to ongoing efforts to strengthen power T&D networks, reducing disruptions in electricity supply and improving overall system resilience in an evolving climate landscape.
26 March 2025 in IEEE Access
The increasing intensity and frequency of extreme events have raised significant concerns about the electrical grid’s resilience. Numerous extreme events such as hurricanes, tornadoes, earthquakes, geomagnetic storms, high-altitude electromagnetic pulses, ice storms, cyber-attacks, and physical attacks, among others, threaten the entire electrical grid and its various components. Fragility curves play a crucial role in assessing asset vulnerability having a significant impact in all studies that evaluate the power system resilience for extreme events. Real-world data for such extreme events are often significantly limited, and thus in this paper a method for calibrating fragility curves with limited real-world data is presented. This paper also introduces a methodology to generate likely temporal sequences of failures during a hurricane event leveraging the newly calibrated fragility curves and the geospatial knowledge utilizing the electric grid resilience & assessment system (EGRASS) tool. Furthermore, the methodology evaluates the sequential contingencies using the dynamic contingency analysis tool (DCAT) for power system dynamic simulations. The main contribution of this work is the development and analysis of the methodology that enables dynamic simulations of power systems under climate-related extreme events using limited real-world data. The methodologies and case studies presented in this paper focus on the hurricanes faced by Puerto Rico’s grid as an extreme event but are agnostic of the type of extreme event and can be applied to other such events.