Naoto Kakuta

Naoto Kakuta

Auto-generated profile, based on publicly available information

Naoto Kakuta

Department of Mechanical Engineering, Tokyo Metropolitan University 1 , 1-1 Minami-Osawa, Hachioji, Tokyo 192-0397, Japan

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2016 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
NKNaoto Kakuta
Naoto Kakuta
HYHiroki Yamashita
Hiroki Yamashita
DKDaisuke Kawashima
Daisuke Kawashima
KKKatsuya Kondo
Katsuya Kondo
HAHidenobu Arimoto
Hidenobu Arimoto
YYYukio Yamada
Yukio Yamada
This paper presents a simultaneous imaging method of temperature and ethanol concentration of ethanol–water mixtures in microfluidic channels. The principle is based on the facts that the absorbance at a wavelength of 1905 nm is dependent on the temperature of water and that the absorbance at 1935 nm is independent of the temperature but strongly dependent on the molar concentration of water, which is reciprocal to the molar concentration of ethanol in the mixture. The absorbance images at the two wavelengths were acquired alternately, each at 50 frames per second, by an alternate irradiation system and near-infrared (NIR) camera, and then converted to the temperature and concentration images by a linear regression model. The imaging method was applied to a dilute ethanol–water mixture with an ethanol concentration of 0.43 M and water flowing side by side in a temperature-controlled Y-channel. The concentration images clearly showed differences between the mixture and water streams, and that the transverse concentration gradient between the two streams decreased downstream by mutual diffusion. It was also confirmed that the mutual diffusion coefficient increased as the temperature increased. The temperature images showed that uniform distributions were immediately formed due to heat transfer between the fluid and channel materials.

25 August 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
NKNaoto Kakuta
Naoto Kakuta
YFYuko Fukuhara
Yuko Fukuhara
KKKatsuya Kondo
Katsuya Kondo
HAHidenobu Arimoto
Hidenobu Arimoto
YYYukio Yamada
Yukio Yamada
This paper presents a remote and preparation-free method of temperature imaging of aqueous solutions in microchannels of microfluidic chips. The principle of this method is based on the temperature dependency of the near-infrared (NIR) absorption band (ν2 + ν3 band) of water. Temperature images were constructed from absorbances in a narrow wavelength range including 1908 nm, the most sensitive to temperature in the band, measured by using an NIR camera and an optical narrow-bandpass filter. Calculation and calibration results demonstrated a linear relationship between the absorption coefficient and temperature with a temperature coefficient of 1.5 × 10−2 K−1 mm−1. Temperature images of 50 μm thick water in a Y-shaped PDMS microchannel locally heated by a neighboring hot wire were obtained, in which thermal diffusion processes in the microchip were visualized. Temperature resolution was estimated to be approximately 0.2 K according to the temperature coefficient and noise level.

1 September 2009 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
NKNaoto Kakuta
Naoto Kakuta
KKKatsuya Kondo
Katsuya Kondo
AOAtsushi Ozaki
Atsushi Ozaki
HAHidenobu Arimoto
Hidenobu Arimoto
YYYukio Yamada
Yukio Yamada

24 April 2008 in Applied Optics
Verified
Journal Article
Closed access
PDF file
NKNaoto Kakuta
Naoto Kakuta
HAHidenobu Arimoto
Hidenobu Arimoto
HMHideyuki Momoki
Hideyuki Momoki
FLFuguo Li
Fuguo Li
YYYukio Yamada
Yukio Yamada
We report a method that uses near-infrared spectroscopy and multivariate analysis to measure the temperature of turbid aqueous solutions. The measurement principle is based on the fact that the peak wavelength of the water absorption band, with its center near 1440 nm, shifts with changes in temperature. This principle was used to measure the temperatures of 1 mm thick samples of aqueous solutions containing Intralipid (2%), which are often used as optical phantoms for biological tissues due to similar scattering characteristics. Temperatures of pure water and aqueous solutions containing glucose (100 mg/ml and 200 mg/ml) were also measured for comparison. For the turbid Intralipid solutions, the absorbance spectrum varied irregularly with time due to the change in scattering characteristics. However, by making use of the difference between the absorbance at 1412 nm and the temperature- independent absorbance at 1440 nm, we obtained SEPs (standard error of prediction) of 0.3 °C and 0.2 °C by univariate linear regression and partial least squares regression, respectively. These accuracies were almost the same as those for the transparent samples (pure water and glucose solution).

31 July 2010 in Optical Review
Verified
Journal Article
Closed access
PDF file
SWShuping Wang
Shuping Wang
NSNanae Shibahara
Nanae Shibahara
DKDaishi Kuramashi
Daishi Kuramashi
SOShinpei Okawa
Shinpei Okawa
NKNaoto Kakuta
Naoto Kakuta
YYYukio Yamada
Yukio Yamada

11 April 2018 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
HYHiroki Yamashita
Hiroki Yamashita
NKNaoto Kakuta
Naoto Kakuta
DKDaisuke Kawashima
Daisuke Kawashima
YYYukio Yamada
Yukio Yamada
The diffusion coefficients of methanol, ethanol, ethylene glycol, and glucose in water, and their temperature dependence are measured by analysing the simultaneously acquired temperature and concentration images. Simultaneous imaging is achieved using two wavelengths, 1905 nm and 1935 nm, in the ν 2 + ν 3 absorption band of water. In the band, the absorbance at 1905 nm is the most sensitive to temperature, whereas that at 1935 nm is independent of the temperature but strongly dependent on the concentration. To measure the diffusion coefficients, the time evolutions of the diffusion lengths are obtained by fitting the analytical solutions of the two-dimensional steady-state diffusion equation to the transverse concentration profiles in a Y-shaped microfluidic channel. The measured diffusion coefficients and their temperature dependence are verified by comparison with literature values.