1 January 2019 in Acta Cirurgica Brasileira
Composite flaps used in reconstructive surgery may intra- and postoperatively suffer from hypoperfusion and/or ischemia-reperfusion influencing wound healing. We aimed to follow-up the effect of ischemia on adipocutaneous flaps' wound healing and microcirculation. In anesthetized rats groin flaps were formed bilaterally. In Control group the flaps were repositioned and sutured back. In Ischemia-Reperfusion (I/R) group before repositioning and suturing the flap pedicles were clamped for 60 minutes. Laser Doppler (LD) fluxmetry and temperature probes were applied on the cranial, central and caudal flap regions before/after preparation and ischemia, re-suturing, and on the 1st-3rd-5th-7th-14th postoperative days, before the final examinations and biopsies for histology. Flaps' skin temperature quickly recovered after repositioning. LD values were lower in the I/R group, reaching a significant level by the 3rd postoperative day, and remained lowered till the 14th day. The magnitude of alterations differed in the flap regions. Histologically normal wound healing process was seen, except for some I/R flaps, where hypertrophized mammary glands were found. Short-term ischemia could influence flap microcirculation and wound healing, and may result in hypertrophized mammary glands. Laser Doppler could be used to evaluate intra- and postoperative microcirculatory changes and may have significance in predicting complications.
7 August 2024 in Journal of Burn Care & Research
Reducing scar size after severe burn injuries is an important and challenging medical, technological, and social problem. We have developed a battery-powered pulsed electric field (PEF) device and surface needle electrode applicator to deliver PEFs to the healing dorsal burn wound in rats. The pulsed electric field was used to treat residual burn wounds caused by metal contact in rats starting 10 days after the injury for 4 months every 11 or 22 days for 4 months using varying time applied voltages at 250-350 V range, 400 mA current, 40 pulses, 70 μs duration each, delivered at pulse repetition frequency 10 Hz at 5 locations inside the wound. We found 40%-45% reduction in the scar size in comparison with untreated controls in both upper and lower dorsal locations on rats’ backs 2 months after the last PEF application. We have not detected significant histopathological differences in the center of the scars besides the thickness of the newly generated epidermis, which was thicker in the PEF-treated group. We showed that minimally invasively applied PEFs through needle electrodes are effective method and device for treating residual burn wounds in the rat model, reducing the size of the resulting scars, without any adverse reaction.