Objective: To analyse ambulatory movements and team dynamics during robot‐assisted surgery ( RAS ), and to investigate whether congestion of the physical space associated with robotic technology led to workflow challenges or predisposed to errors and adverse events. Methods: With institutional review board approval, we retrospectively reviewed 10 recorded robot‐assisted radical prostatectomies in a single operating room ( OR ). The OR was divided into eight zones, and all movements were tracked and described in terms of start and end zones, duration, personnel and purpose. Movements were further classified into avoidable (can be eliminated/improved) and unavoidable (necessary for completion of the procedure). Results: The mean operating time was 166 min, of which ambulation constituted 27 min (16%). A total of 2 896 ambulatory movements were identified (mean: 290 ambulatory movements/procedure). Most of the movements were procedure‐related (31%), and were performed by the circulating nurse. We identified 11 main pathways in the OR ; the heaviest traffic was between the circulating nurse zone, transit zone and supply‐1 zone. A total of 50% of ambulatory movements were found to be avoidable. Conclusion: More than half of the movements during RAS can be eliminated with an improved OR setting. More studies are needed to design an evidence‐based OR layout that enhances access, workflow and patient safety.
Introduction: We sought to evaluate the Robotic Anastomosis Competency Evaluation (RACE) — a validated tool that objectively quantifies surgical skills specifically for urethrovesical anastomosis (UVA) — as a means to track progress of trainees, as well as to determine its predictive value. Methods: UVAs performed by trainees at our institution were evaluated using RACE over a period of two years. Trainees were supervised by an experienced robotic surgeon. Outcomes included traineerelated variables (RACE score, proportion of UVA performed by trainee, and suturing speed), and clinical outcomes (total UVA duration, postoperative urinary continence, and UVA-related complications). Significance was determined using linear regression analysis. Results: A total of 51 UVAs performed by six trainees were evaluated. Trainee RACE scores (19.8 to 22.3; p=0.01) and trainee proportion of UVA (67% to 80%; p=0.003) improved significantly over time. Trainee suture speed was significantly associated with RACE score (mean speed range 0.54–0.74 sutures/minute; p=0.03). Neither urinary continence at six weeks nor at six months was significantly associated with RACE score (p=0.17 and p=0.15, respectively), and only one UVA-related postoperative complication was reported. Conclusions: Trainee RACE scores improved and the proportion of UVA performed by trainees increased over time. RACE can be used as an objective measure of surgical performance during training. Strict mentor supervision allowed safe training without compromising patient outcomes.