6 June 2024 in IEEE Transactions on Industrial Electronics
The vibroacoustic level has become a key factor for evaluating permanent magnet motor performance in recent years. However, the influence of tangential force is usually ignored, which will lead to errors in vibration noise calculation and limit the idea of reducing motor vibration noise. In this article, a comprehensive investigation of the tangential - and radial forces and their effects on the motor vibration is conducted. First, the analytical method of the electromagnetic force is presented. Next, the finite element method is applied to analyze the electromagnetic laws of radial force and tangential force. Then, the Theorem of Translation of A Force (TTF) is introduced to describe the influence of tangential force on radial vibration. After that, the influencing factors of stator teeth and load on the radial- and tangential-force are discussed, especially the phase relationship. Finally, the electromagnetic vibration law caused by radial force and tangential force is simulated and verified by experiments. The results can provide guidance for design of low vibroacoustic motor considering radial force and tangential force.
30 May 2024 in IEEE Transactions on Energy Conversion
Doubly-fed motors are extensively employed as high-capacity variable speed pumped hydro (VSPH) machines. The Fengning Pumped Storage Power Station in Hebei province constructed the first two VSPH machines in China. However, the rotor protection for the Fengning VSPH unit has not been completed to date, and traditional protection methods exhibit inherent deficiencies. To design an appropriate rotor protection scheme for the VSPH machines, it is vital to ascertain the internal fault characteristics through an accurate simulation model. Nonetheless, the commonly used dq0 model fails to account for all harmonics. To address this limitation, this paper proposes a multi-loop model to analyze the internal fault characteristics of VSPH machine windings. Experimental validation conducted on a 12kW VSPH prototype demonstrates the model's ability to accurately predict voltage and current waveforms under different internal fault conditions. Subsequently, the internal fault characteristics of the investigated VSPH prototype are determined by performing harmonic analysis on the stator and rotor currents. The observation and analysis results indicate that the utilization of fractional order currents in stator branches can effectively safeguard the rotor windings of VSPH machines.
23 August 2019 in IEEE Transactions on Energy Conversion
An excitation system with a multiphase angular brushless exciter is the preferred nuclear power excitation scheme because of its low output voltage ripple. However, interturn short circuits of the stator field windings (ISCFW) often occur in the brushless exciter, affecting the normal operation of the system. To study this type of fault, this paper presents research on theoretical analysis, simulation calculation and model machine experiments. First, through the analysis of the magnetomotive force produced by windings and their interaction in the air gap under fault, the frequency domain characteristics of the postfault steady-state current are obtained. A general multi-loop-method-based mathematical model of multiphase angular brushless excitation system with ISCFW is established. Correlated simulations and experiments with ISCFW are carried out, verifying the result of the theoretical analysis: $m/P$ times harmonics are in the field current, while all harmonics are in the armature current. The general theoretical analysis method and mathematical modeling method proposed in this paper provide a basis for the protection scheme to rapidly remove ISCFW that occurs in the multiphase angular brushless exciter.