25 October 2012 in IEEE Transactions on Power Systems
Deregulation of energy markets, penetration of renewables, advanced metering capabilities, and the urge for situational awareness, all call for system-wide power system state estimation (PSSE). Implementing a centralized estimator though is practically infeasible due to the complexity scale of an interconnection, the communication bottleneck in real-time monitoring, regional disclosure policies, and reliability issues. In this context, distributed PSSE methods are treated here under a unified and systematic framework. A novel algorithm is developed based on the alternating direction method of multipliers. It leverages existing PSSE solvers, respects privacy policies, exhibits low communication load, and its convergence to the centralized estimates is guaranteed even in the absence of local observability. Beyond the conventional least-squares based PSSE, the decentralized framework accommodates a robust state estimator. By exploiting interesting links to the compressive sampling advances, the latter jointly estimates the state and identifies corrupted measurements. The novel algorithms are numerically evaluated using the IEEE 14-, 118-bus, and a 4200-bus benchmarks. Simulations demonstrate that the attainable accuracy can be reached within a few inter-area exchanges, while largest residual tests are outperformed.
19 August 2013 in IEEE Signal Processing Magazine
Although the North American power grid has been recognized as the most important engineering achievement of the 20th century, the modern power grid faces major challenges [87]. Increasingly complex interconnections even at the continent size render prevention of the rare yet catastrophic cascade failures a strenuous concern. Environmental incentives require carefully revisiting how electrical power is generated, transmitted, and consumed, with particular emphasis on the integration of renewable energy resources. Pervasive use of digital technology in grid operation demands resiliency against physical and cyberattacks on the power infrastructure. Enhancing grid efficiency without compromising stability and quality in the face of deregulation is imperative. Soliciting consumer participation and exploring new business opportunities facilitated by the intelligent grid infrastructure hold a great economic potential.
10 December 2014 in IEEE Transactions on Power Systems
Distribution microgrids are being challenged by reverse power flows and voltage fluctuations due to renewable generation, demand response, and electric vehicles. Advances in photovoltaic (PV) inverters offer new opportunities for reactive power management provided PV owners have the right investment incentives. In this context, reactive power compensation is considered here as an ancillary service. Accounting for the increasing time-variability of distributed generation and demand, a stochastic reactive power compensation scheme is developed. Given uncertain active power injections, an online reactive control scheme is devised. This scheme is distribution-free and relies solely on power injection data. Reactive injections are updated using the Lagrange multipliers of a second-order cone program. Numerical tests on an industrial 47-bus microgrid and the residential IEEE 123-bus feeder corroborate the reactive power management efficiency of the novel stochastic scheme over its deterministic alternative, as well as its capability to track variations in solar generation and household demand.
28 April 2017 in IEEE Transactions on Smart Grid
SVSriharsha Veeramachaneni
Due to limited instrumentation, distribution grids are currently challenged by observability issues. On the other hand, smart meter data are communicated to utility operators from nodes with renewable generation and elastic demand. This paper employs grid data from metered buses toward inferring the underlying grid state. System nodes are partitioned into buses with time-varying injections that are assumed metered, and buses with relatively stationary conventional loads that are non-metered. Exploiting the variability at metered buses and the stationarity of conventional loads, the novel idea here is to solve the non-linear power flow (PF) equations jointly over consecutive time instants. By putting forth a coupled formulation of the PF problem (CPF), grid states can be recovered by metering fewer buses. An intuitive and easily verifiable rule pertaining to the locations of (non-)metered buses on the physical grid is shown to be a necessary and sufficient criterion for local observability in radial networks. To account for noisy smart meter readings, a coupled power system state estimation (CPSSE) problem is further devised. Both CPF and CPSSE tasks are tackled via augmented semi-definite program relaxations. The observability criterion along with the CPF and CPSSE solvers are numerically corroborated using randomly generated and actual solar and load data on the IEEE 34-bus benchmark feeder.
24 February 2012 in IEEE Transactions on Power Systems
Instrumenting power networks with phasor measurement units (PMUs) facilitates several tasks including optimum power flow, system control, contingency analysis, visualization, and integration of renewable resources, thus enabling situational awareness-one of the key steps toward realizing the smart grid vision. The installation cost of PMUs currently prohibits their deployment on every bus, which in turn motivates their strategic placement across the power grid. As state estimation is at the core of grid monitoring, PMU deployment is optimized here based on estimation-theoretic criteria. Considering both voltage and incident current readings per PMU-instrumented bus and incorporating conventionally derived state estimates under the Bayesian framework, PMU placement is formulated as an optimal experimental design task. To bypass the combinatorial search involved, a convex relaxation is developed to obtain solutions with numerical optimality guarantees. In the tests performed on standard IEEE 14-, 30-, and 118-bus benchmarks, the proposed relaxation approaches and oftentimes attains the optimum PMU placement.
2 October 2017 in IEEE Transactions on Smart Grid
SVSriharsha Veeramachaneni
Distribution grids constitute complex networks of lines oftentimes reconfigured to minimize losses, balance loads, alleviate faults, or for maintenance purposes. Topology monitoring becomes a critical task for optimal grid scheduling. While synchrophasor installations are limited in low-voltage grids, utilities have an abundance of smart meter data at their disposal. In this context, a statistical learning framework is put forth for verifying single-phase grid structures using non-synchronized voltage data. The related maximum likelihood task boils down to minimizing a non-convex function over a non-convex set. The function involves the sample voltage covariance matrix and the feasible set is relaxed to its convex hull. Asymptotically in the number of data, the actual topology yields the global minimizer of the original and the relaxed problems. Under a simplified data model, the function turns out to be convex, thus offering optimality guarantees. Prior information on line statuses is also incorporated via a maximum a-posteriori approach. The formulated tasks are tackled using solvers having complementary strengths. Numerical tests using real data on benchmark feeders demonstrate that reliable topology estimates can be acquired even with a few smart meter data, while the non-convex schemes exhibit superior line verification performance at the expense of additional computational time.