Lily Koffman

Lily Koffman

Auto-generated profile, based on publicly available information

Lily Koffman

Department of Biostatistics, Johns Hopkins School of Public Health, Baltimore, MD, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2023 in Journal of the American Heart Association
Verified
Journal Article
Open access
LKLily J. Koffman
Lily J. Koffman
CCCiprian M. Crainiceanu
Ciprian M. Crainiceanu
RRRyan Roemmich
Ryan Roemmich
MFMargaret A. French
Margaret A. French
Background: Low physical activity (PA) is associated with poor health outcomes after stroke. Step counts are a common metric of PA; however, other physiologic signals (eg, heart rate) may help to identify subgroups of individuals poststroke at varying levels of risk of poor health outcomes. Here, we aimed to identify clinically relevant subgroups of individuals poststroke based on PA profiles that leverage multiple data sources, including step count and heart rate data, from wearable devices. Methods and Results: Seventy individuals poststroke participated. Participants wore a Fitbit Inspire 2 for 1 year and completed clinical assessments. We defined a group‐based steps‐per‐minute threshold and an individual heart rate threshold to categorize each minute of PA into 1 of 4 states: high steps/high heart rate, low steps/low heart rate, high steps/low heart rate, and low steps/high heart rate. We used the proportion of time spent in each state along with steps per day, sedentary time, mean steps among minutes with high steps and high heart rate, and resting heart rate in a k‐means clustering algorithm to identify subgroups and compared Activity Measure for Post‐Acute Care Mobility T Score, Stroke Impact Scale, and gait speed among subgroups. We identified 3 subgroups, Active (n=8), Sedentary (n=29), and Deconditioned (n=33), which differed significantly on all clustering variables except resting heart rate. We observed significant differences in Activity Measure for Post‐Acute Care Mobility T scores between subgroups, with the Deconditioned subgroup exhibiting the lowest score. Conclusions: Quantifying PA with heart rate and step count using readily available wearable devices can identify clinically meaningful subgroups of individuals poststroke.

26 November 2024 in Medicine & Science in Sports & Exercise
Verified
Journal Article
Closed access
LKLily Koffman
Lily Koffman
CCCiprian Crainiceanu
Ciprian Crainiceanu
JMJohn Muschelli
John Muschelli
Purpose: To quantify the relative performance of step counting algorithms in studies that collect free-living high-resolution wrist accelerometry data and to highlight the implications of using these algorithms in translational research. Methods: Five step counting algorithms (four open source and one proprietary) were applied to the publicly available, free-living, high-resolution wrist accelerometry data collected by the National Health and Nutrition Examination Survey (NHANES) in 2011–2014. The mean daily total step counts were compared in terms of correlation, predictive performance, and estimated hazard ratios of mortality. Results: The estimated number of steps were highly correlated (median, 0.91; range, 0.77–0.98), had high and comparable predictive performance of mortality (median concordance, 0.72; range, 0.70–0.73). The distributions of the number of steps in the population varied widely (mean step counts range from 2453 to 12,169). Hazard ratios of mortality associated with a 500-step increase per day varied among step counting algorithms between HR = 0.88 and 0.96, corresponding to a 300% difference in mortality risk reduction ([1–0.88] / [1–0.96] = 3). Conclusions: Different step counting algorithms provide correlated step estimates and have similar predictive performance that is better than traditional predictors of mortality. However, they provide widely different distributions of step counts and estimated reductions in mortality risk for a 500-step increase.

19 January 2021 in Obesity Surgery
Verified
Journal Article
Closed access
PDF file
LKLily Koffman
Lily Koffman
ALAlexander W. Levis
Alexander W. Levis
DADavid Arterburn
David Arterburn
KCKaren J. Coleman
Karen J. Coleman
LHLisa J. Herrinton
Lisa J. Herrinton
SHSebastien Haneuse
Sebastien Haneuse

19 October 2021 in Obesity Surgery
Verified
Journal Article
Closed access
PDF file
LKLily Koffman
Lily Koffman
ALAlexander W. Levis
Alexander W. Levis
SHSebastien Haneuse
Sebastien Haneuse
EJEric Johnson
Eric Johnson
SBSteven Bock
Steven Bock
DADavid Arterburn
David Arterburn

1 January 2024 in Journal for the Measurement of Physical Behaviour
Verified
Journal Article
Closed access
PDF file
LKLily Koffman
Lily Koffman
JMJohn Muschelli
John Muschelli
Background: Walking-based metrics, including step count and total time walking, are easily interpretable measures of physical activity. Algorithms can estimate steps from accelerometry, which increasingly is measured with accelerometers located on the wrist. However, many existing step counting algorithms have not been validated in free-living settings, exhibit high error rates, or cannot be used without proprietary software. We compare the performance of several existing open-source step counting algorithms on three publicly available data sets, including one with free-living data. Methods: We applied five open-source algorithms: Adaptive Empirical Pattern Transformation, Oak, Step Detection Threshold, Verisense, and stepcount, and one proprietary algorithm (ActiLife) to three publicly available data sets with ground truth step counts: Clemson Ped-Eval, Movement Analysis in Real-World Environments Using Accelerometers, and OxWalk. We evaluate F1 score, precision, recall, mean absolute percent error (MAPE), and mean bias for each algorithm and setting. Results: The machine learning-based stepcount algorithm exhibited the highest F1 score (0.89 ± 0.11) and lowest MAPE (8.6 ± 9%) across all data sets and had the best, or comparable, F1 scores and MAPE in each individual data set. All algorithms performed worse with respect to both F1 score and MAPE in free-living compared with regular walking scenarios, and stepcount and Verisense were most sensitive to sampling frequency of input data. Conclusion: Machine learning-based algorithms, including stepcount, are a promising avenue for step counting. More free-living accelerometry data sets with ground truth step counts are needed for testing, validation, and continued refinement of algorithms.

4 May 2023 in Gait & Posture
Verified
Journal Article
Closed access
LKLily Koffman
Lily Koffman
YZYan Zhang
Yan Zhang
JHJaroslaw Harezlak
Jaroslaw Harezlak
CCCiprian Crainiceanu
Ciprian Crainiceanu
ALAndrew Leroux
Andrew Leroux