Ranita Tarchand

Ranita Tarchand

Auto-generated profile, based on publicly available information

Ranita Tarchand

Nested Knowledge, Inc., St. Paul, MN 55117, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2023 in Journal of Comparative Effectiveness Research
Verified
Journal Article
Open access
OZOsama O Zaidat
Osama O Zaidat
SIShelly Ikeme
Shelly Ikeme
SSSunil A Sheth
Sunil A Sheth
SYShinichi Yoshimura
Shinichi Yoshimura
XYXin-Guang Yang
Xin-Guang Yang
TATommy Andersson
Tommy Andersson
Aim: Stent-retriever (SR) thrombectomy has demonstrated superior outcomes in patients with acute ischemic stroke compared with medical management alone, but differences among SRs remain unexplored. We conducted a Systematic Review/Meta-Analysis to compare outcomes between three SRs: EmboTrap ® , Solitaire™, and Trevo ® . Methods: We conducted a PRISMA-compliant Systematic Review among English-language studies published after 2014 in PubMed/MEDLINE that reported SRs in ≥25 patients. Functional and safety outcomes included 90-day modified Rankin scale (mRS 0-2), mortality, symptomatic intracranial hemorrhage (sICH), and embolization to new territory (ENT). Recanalization outcomes included modified thrombolysis in cerebral infarction (mTICI) and first-pass recanalization (FPR). We used a random effects Meta-Analysis to compare outcomes; subgroup and outlier-influencer analysis were performed to explore heterogeneity. Results: Fifty-one articles comprising 9,804 patients were included. EmboTrap had statistically significantly higher rates of mRS 0-2 (57.4%) compared with Trevo (50.0%, p = 0.013) and Solitaire (45.3%, p < 0.001). Compared with Solitaire (20.4%), EmboTrap (11.2%, p < 0.001) and Trevo (14.5%, p = 0.018) had statistically significantly lower mortality. Compared with Solitaire (7.7%), EmboTrap (3.9%, p = 0.028) and Trevo (4.6%, p = 0.049) had statistically significantly lower rates of sICH. There were no significant differences in ENT rates across all three devices (6.0% for EmboTrap, 5.3% for Trevo, and 7.7% for Solitaire, p = 0.518). EmboTrap had numerically higher rates of recanalization; however, no statistically significant differences were found. Conclusion: The results of our Systematic Review/Meta-Analysis suggest that EmboTrap may be associated with significantly improved functional outcomes compared with Solitaire and Trevo. EmboTrap and Trevo may be associated with significantly lower rates of sICH and mortality compared with Solitaire. No significant differences in recanalization and ENT rates were found. These conclusions are tempered by limitations of the analysis including variations in thrombectomy techniques in the field, highlighting the need for multi-arm RCT studies comparing different SR devices to confirm our findings.

2 June 2026 in JMIR Preprints
Verified
Preprint
Open access
KKKevin Kallmes
Kevin Kallmes
JTJade Thurnham
Jade Thurnham
MSMarius Sauca
Marius Sauca
RTRanita Tarchand
Ranita Tarchand
JTJoshua Twaites
Joshua Twaites
KHKarl J. Holub
Karl J. Holub
BACKGROUND While artificial intelligence (AI) tools have been utilized for individual stages within the systematic literature review (SLR) process, no tool has previously been shown to support each critical SLR step. In addition, expert oversight is required for responsible use of AI to ensure the quality of SLR findings. OBJECTIVE To describe a complete methodology for utilizing our AI SLR tool with human-in-the-loop curation workflows, as well as AI validations, time savings, and approaches to ensure compliance with best review practices. METHODS SLRs require completing search, screening, and extraction from relevant studies, with qualitative synthesis, meta-analysis, and critical appraisal as relevant. We present a full methodological framework for completing SLRs utilizing our AutoLit® software (Nested Knowledge). This system integrates AI models into the central steps in SLR: search strategy generation, dual screening of titles/abstracts and full texts, extraction of qualitative and quantitative evidence, critical appraisal, and insight drafting, with fully automated network meta-analysis. Validations comparing AI performance to experts are reported, and where relevant, time savings within the SLR workflow. RESULTS Across the SLR workflow, Nested Knowledge AI tools showed strongest evidence for search development, screening support, structured tagging, and extraction efficiency. Smart Search translated research questions into Boolean strings with 76.8% and 79.6% recall across two validation sets. For title/abstract screening, The Inclusion Prediction Model achieved 82%–97.1% recall, while criteria-based Smart Screener achieved approximately 95% accuracy, 80% time savings, and high recall in autonomous abstract/full-text screening. Core Smart Tags achieved F1=0.74 for PICO extraction and hierarchy building, with 74%, 78%, and 91% accuracy for study type, location, and study size, respectively. Adaptive Smart Tags demonstrated 68.4% expert overlap for version 1, while early version 2 evaluations showed 76% recall/69% precision overall and stronger performance for structured abstract-level concepts. Smart Meta-Analytical Extraction produced >95% time savings for quantitative extraction, and Smart Insights scored highest for citation integrity (4.9/5) and synthesis quality (4.4/5). Smart Critical Appraisal supports structured, framework-based appraisal, though validation evidence remains more limited. CONCLUSIONS AI-enabled SLR tools with human-in-the-loop can reduce reviewer burden and accelerate evidence-review workflows without replacing expert judgment. Transparent methods, reproducible outputs, traceable evidence links, and human oversight are essential for ensuring that efficiency gains do not compromise review quality.