Daniel Bestourous

Daniel Bestourous

Auto-generated profile, based on publicly available information

Daniel Bestourous

Division of Otolaryngology–Head & Neck Surgery, George Washington University School of Medicine & Health Sciences

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in American Journal of Otolaryngology
Verified
Journal Article
Closed access
DBDaniel E. Bestourous
Daniel E. Bestourous
LPLuke J. Pasick
Luke J. Pasick
DBDaniel A. Benito
Daniel A. Benito
PZPhilip E. Zapanta
Philip E. Zapanta

1 March 2020 in World Neurosurgery
Verified
Journal Article
Closed access
NANeil D. Almeida
Neil D. Almeida
RLRyan Lee
Ryan Lee
DBDaniel Bestourous
Daniel Bestourous
AKAndrea Klein
Andrea Klein
NPNeil R. Parekh
Neil R. Parekh
JSJonathan H. Sherman
Jonathan H. Sherman

9 September 2021 in Otology & Neurotology
Verified
Journal Article
Closed access
DBDaniel E. Bestourous
Daniel E. Bestourous
LDLauren Davidson
Lauren Davidson
BRBrian K. Reilly
Brian K. Reilly
Objectives: This study looks to examine how the development of diametric magnet cochlear implant devices (CIDs) has affected observed magnetic resonance imaging (MRI)-related adverse events and MRI safety measures. Methods: A search of the Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database was conducted using the product code “MCM” for “Cochlear implants.” Reports were included for analysis if they involved MRI in recipients of cochlear implantation. Included reports were stratified into two cohorts by year: 2010 to 2014 and 2015 to 2020, reflecting the FDA approval of diametric magnet cochlear implants in 2015. Extracted event variables included implant manufacturer, adherence to MRI protocol, patient injuries, and device malfunctions. Results: The product code search query yielded a total of 27,305 reports, from which 584 reports were included for analysis. From 2010 to 2014, there were 109 adverse events and 30 pre-MRI explantations. Implant displacement was the most common device malfunction (n = 69, 87.3%), and pain was the most common patient injury (n = 16, 53.3%). From 2015 to 2020, there were 566 adverse events and 62 pre-MRI explantations. The most common device malfunction was implant displacement (n = 365, 94.6%) and pain was the most common patient injury (n = 114, 63.3%). Only 64/114 (56.1%) reports after 2015 reported adherence to the recommended MRI protocol. No adverse events occurred in patients with synchrony diametric-magnet CIDs. Conclusion: Despite the advent of FDA-approved MRI-safe diametric magnet devices, implanted patients are still experiencing injury, explantation, and device malfunction, and providers are reporting poor compliance with MRI safety protocols.

1 March 2021 in Journal of Orthopaedics
Verified
Journal Article
Closed access
CWChapman Wei
Chapman Wei
AGAlex Gu
Alex Gu
NANeil D. Almeida
Neil D. Almeida
DBDaniel Bestourous
Daniel Bestourous
TQTheodore Quan
Theodore Quan
SMSam Moghtaderi
Sam Moghtaderi

22 October 2020 in BMJ Case Reports
Verified
Journal Article
Closed access
PDF file
DBDaniel Bestourous
Daniel Bestourous
MMMargaret Michel
Margaret Michel
CBChristopher Badger
Christopher Badger
PTPunam Thakkar
Punam Thakkar
AJArjun S Joshi
Arjun S Joshi
A 74-year-old man was referred to a tertiary academic otolaryngology clinic for evaluation of a left-sided neck mass with unknown primary. Nuclear imaging modalities revealed a primary cancer located at the left tongue base. Further investigation revealed the tumour to be a p16 positive squamous cell cancer with metastatic spread to cervical lymph nodes of multiple levels. The patient was found on initial investigation to have microstomia and a retrognathic mandible, which are typically considered unsuitable for robotic surgery due to difficulties obtaining adequate exposure. The patient underwent bilateral neck dissection, followed by transoral robotic-assisted left base of tongue resection. A midline intraoral mandibulotomy was performed to improve robotic access. Following tumour resection, the mandible was repaired using open reduction with internal plate fixation. Postoperative occlusion was maintained, and the patient recovered well from mandibulotomy with none of the morbidity or cosmetic defects associated with a traditional lip-split approach.