Peter Quicke

Peter Quicke

Auto-generated profile, based on publicly available information

Peter Quicke

Imperial College London, Department of Bioengineering, London

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2019 in Frontiers in Cellular Neuroscience
Verified
Journal Article
Open access
PDF file
PQPeter Quicke
Peter Quicke
CSChenchen Song
Chenchen Song
EMEric J. McKimm
Eric J. McKimm
MMMilena M. Milosevic
Milena M. Milosevic
CHCarmel L. Howe
Carmel L. Howe
TKThomas Knöpfel
Thomas Knöpfel
Voltage imaging of many neurons simultaneously at single-cell resolution is hampered by the difficulty of detecting small voltage signals from overlapping neuronal processes in neural tissue. Recent advances in genetically encoded voltage indicator (GEVI) imaging have shown single-cell resolution optical voltage recordings in intact tissue through imaging naturally sparse cell classes, sparse viral expression, soma restricted expression, advanced optical systems, or a combination of these. Widespread sparse and strong transgenic GEVI expression would enable straightforward optical access to a densely occurring cell type, such as cortical pyramidal cells. Here we demonstrate that a recently described sparse transgenic expression strategy can enable single-cell resolution voltage imaging of cortical pyramidal cells in intact brain tissue without restricting expression to the soma. We also quantify the functional crosstalk in brain tissue and discuss optimal imaging rates to inform future GEVI experimental design.

28 September 2016 in Proceedings of the IEEE
Verified
Journal Article
Open access
SSSimon Schultz
Simon Schultz
CCCaroline S. Copeland
Caroline S. Copeland
AFAmanda J. Foust
Amanda J. Foust
PQPeter Quicke
Peter Quicke
RSRenaud Schuck
Renaud Schuck
Recent years have seen substantial developments in technology for imaging neural circuits, raising the prospect of large-scale imaging studies of neural populations involved in information processing, with the potential to lead to step changes in our understanding of brain function and dysfunction. In this paper, we will review some key recent advances: improved fluorophores for single-cell resolution functional neuroimaging using a two-photon microscope; improved approaches to the problem of scanning active circuits; and the prospect of scanless microscopes which overcome some of the bandwidth limitations of current imaging techniques. These advances in technology for experimental neuroscience have in themselves led to technical challenges, such as the need for the development of novel signal processing and data analysis tools in order to make the most of the new experimental tools. We review recent work in some active topics, such as region of interest segmentation algorithms capable of demixing overlapping signals, and new highly accurate algorithms for calcium transient detection. These advances motivate the development of new data analysis tools capable of dealing with spatial or spatiotemporal patterns of neural activity that scale well with pattern size.

28 August 2020 in Neurophotonics
Verified
Journal Article
Open access
PDF file
PQPeter Quicke
Peter Quicke
CHCarmel L. Howe
Carmel L. Howe
PSPingfan Song
Pingfan Song
HJHerman V. Jadan
Herman V. Jadan
CSChenchen Song
Chenchen Song
AFAmanda J. Foust
Amanda J. Foust
Cellular resolution voltage imaging enables direct observation of neuronal computation. Indeed, membrane potential imaging experiments have spatiotemporally resolved both active and passive action, and synaptic potential generation throughout dendritic and axonal arbors.1 – 14 Resolution of these small voltage signals at high speeds requires high photon fluxes, making wide-field single-photon (1P) imaging by far the most common voltage imaging modality. Imaging neuronal processes with this technique require the imaged membranes to lie approximately flat in the microscope’s focal plane. As these experiments are typically performed in slices, the requirement for flat, healthy, and superficial cells represents a significant barrier to entry for experimenters. Even in the best-prepared slices, anatomy dictates that only a few cells will be oriented parallel to the surface, reducing experimental throughput, and only certain cell types feature morphology that can be well-sampled by a single plane. Iterative three-dimensional (3-D) imaging in wide field via physical refocusing is often untenable due to rapid sample bleaching. Multiple approaches to improve wide-field imaging’s 3-D performance have been developed. Anselmi et al.15 applied remote focusing to axially shift and tilt the wide-field focal plane as required by the sample, enabling calcium imaging along tilted dendrites. This adaptation, however, costs half of the fluorescence emission and is limited to a single tilted plane at a time. Point spread function (PSF) engineering via cubic phase masks16 or spherical aberration17 also enables parallelized volumetric sample imaging when combined with light-sheet excitation; however, to our knowledge, these approaches have not successfully been implemented to image membrane voltage.

29 May 2020 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Open access
PSPingfan Song
Pingfan Song
HJHerman Verinaz Jadan
Herman Verinaz Jadan
CHCarmel L. Howe
Carmel L. Howe
PQPeter Quicke
Peter Quicke
AFAmanda J. Foust
Amanda J. Foust
PDPier Luigi Dragotti
Pier Luigi Dragotti
Light-field microscopy (LFM) is a type of all-optical imaging system that is able to capture 4D geometric information of light rays and can reconstruct a 3D model from a single snapshot. In this paper, we propose a new 3D localization approach to effectively detect 3D positions of neuronal cells from a single light-field image with high accuracy and outstanding robustness to light scattering. This is achieved by constructing a depth-aware dictionary and by combining it with convolutional sparse coding. Specifically, our approach includes 3 key parts: light-field calibration, depth-aware dictionary construction, and localization based on convolutional sparse coding (CSC). In the first part, an observed raw light-field image is calibrated and then decoded into a two-plane parameterized 4D format which leads to the epi-polar plane image (EPI). The second part involves simulating a set of light-fields using a wave-optics forward model for a ball-shaped volume that is located at different depths. Then, a depth-aware dictionary is constructed where each element is a synthetic EPI associated to a specific depth. Finally, by taking full advantage of the sparsity prior and shift-invariance property of EPI, 3D localization is achieved via convolutional sparse coding on an observed EPI with respect to the depth-aware EPI dictionary. We evaluate our approach on both non-scattering specimen (fluorescent beads suspended in agarose gel) and scattering media (brain tissues of genetically encoded mice). Extensive experiments demonstrate that our approach can reliably detect the 3D positions of granular targets with small Root Mean Square Error (RMSE), high robustness to optical aberration and light scattering in mammalian brain tissues.

9 January 2019 in Journal of Physics D: Applied Physics
Verified
Journal Article
Open access
PDF file
NSNavjeevan Singhh Soor
Navjeevan Singhh Soor
PQPeter Quicke
Peter Quicke
CHCarmel L Howe
Carmel L Howe
KPKuin Tian Pang
Kuin Tian Pang
MNMark A A Neil
Mark A A Neil
AFAmanda Joy Foust
Amanda Joy Foust
All optical neurophysiology allows manipulation and readout of neural network activity with single-cell spatial resolution and millisecond temporal resolution. Neurons can be made to express proteins that actuate transmembrane currents upon light absorption, enabling optical control of membrane potential and action potential signalling. In addition, neurons can be genetically or synthetically labelled with fluorescent reporters of changes in intracellular calcium concentration or membrane potential. Thus, to optically manipulate and readout neural activity in parallel, two spectra are involved: the action spectrum of the actuator, and the absorption spectrum of the fluorescent reporter. Due to overlap in these spectra, previous all-optical neurophysiology paradigms have been hindered by spurious activation of neuronal activity caused by the readout light. Here, we pair the blue-green absorbing optogenetic actuator, Chronos, with a deep red-emitting fluorescent calcium reporter CaSiR-1. We show that cultured Chinese hamster ovary cells transfected with Chronos do not exhibit transmembrane currents when illuminated with wavelengths and intensities suitable for exciting one-photon CaSiR-1 fluorescence. We then demonstrate crosstalk-free, high signal-to-noise ratio CaSiR-1 red fluorescence imaging at 100 frames s−1 of Chronos-mediated calcium transients evoked in neurons with blue light pulses at rates up to 20 Hz. These results indicate that the spectral separation between red light excited fluorophores, excited efficiently at or above 640 nm, with blue-green absorbing opsins such as Chronos, is sufficient to avoid spurious opsin actuation by the imaging wavelengths and therefore enable crosstalk-free all-optical neuronal manipulation and readout.

12 July 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
PQPeter Quicke
Peter Quicke
SRStephanie Reynolds
Stephanie Reynolds
MNMark Neil
Mark Neil
TKThomas Knöpfel
Thomas Knöpfel
SSSimon Schultz
Simon Schultz
AFAmanda J. Foust
Amanda J. Foust
Multifocal two-photon microscopy (MTPM) increases imaging speed over single-focus scanning by parallelizing fluorescence excitation. The imaged fluorescence’s susceptibility to crosstalk, however, severely degrades contrast in scattering tissue. Here we present a source-localized MTPM scheme optimized for high speed functional fluorescence imaging in scattering mammalian brain tissue. A rastered line array of beamlets excites fluorescence imaged with a complementary metal-oxide-semiconductor (CMOS) camera. We mitigate scattering-induced crosstalk by temporally oversampling the rastered image, generating grouped images with structured illumination, and applying Richardson-Lucy deconvolution to reassign scattered photons. Single images are then retrieved with a maximum intensity projection through the deconvolved image groups. This method increased image contrast at depths up to 112 μm in scattering brain tissue and reduced functional crosstalk between pixels during neuronal calcium imaging. Source-localization did not affect signal-to-noise ratio (SNR) in densely labeled tissue under our experimental conditions. SNR decreased at low frame rates in sparsely labeled tissue, with no effect at frame rates above 50 Hz. Our non-descanned source-localized MTPM system enables high SNR, 100 Hz capture of fluorescence transients in scattering brain, increasing the scope of MTPM to faster and smaller functional signals.