Deshpande Gururaj Abhilash Krishna

Deshpande Gururaj Abhilash Krishna

Auto-generated profile, based on publicly available information

Deshpande Gururaj Abhilash Krishna

Department of Electrical and Electronics Engineering, National Institute of Technology Karnataka, Surathkal

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
KAKarthikeyan Anbalagan
Karthikeyan Anbalagan
DKDeshpande Gururaj Abhilash Krishna
Deshpande Gururaj Abhilash Krishna
SKSushant Kumar
Sushant Kumar
BPB. Venkatesa Perumal
B. Venkatesa Perumal
SMSukumar Mishra
Sukumar Mishra
For effective operation of Dynamic Voltage Restorer (DVR) control strategy plays significant role. This paper presents enhanced control strategy for DVR using dual role Cascaded Delay Signal Cancellation (CDSC) based Dual Vector Control (DVC) under unbalanced and distorted grid conditions. Based on the numerical analysis it is found that CDSC prefilter is promising solution when grid voltage is distorted by symmetric, asymmetric harmonics and unbalanced sag. Mainly, CDSC prefilter extracts Instantaneous Symmetrical Components (ISC) of the grid voltage required for voltage sags detection and generation of fundamental component of reference voltage for the DVR. A CDSC based DVC algorithm with inductor current and capacitor voltage feedback is implemented in synchronous reference frame, which tracks the fundamental DVR reference voltages. An extractor based on modified CDSC strategy is designed to extract harmonics from load voltage during distorted grid conditions. These extracted harmonic components (non-fundamental) are added in phase opposition with fundamental component and fed to PWM block to generate reference voltages. Experimental studies are conducted on scaled down (100 V, 0.5kVA) laboratory prototype DVR to verify the effectiveness of the proposed control algorithm under unbalanced and distorted grid conditions.

6 November 2020 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
Verified
Journal Article
Closed access
DKDeshpande Gururaj Abhilash Krishna
Deshpande Gururaj Abhilash Krishna
KAKarthikeyan Anbalagan
Karthikeyan Anbalagan
PKPrabhakaran K K
Prabhakaran K K
SKSushant Kumar
Sushant Kumar
Grid integration of distributed energy resources (DER) has become a technical challenge in the distribution network operation due to the intermittent nature of renewable energy sources and their impact on grid voltage stability. Thus, a Dynamic Voltage Restorer (DVR) is installed in the distribution network system to reduce such grid voltage impact on sensitive loads. In this paper, a Pseudo Derivative Feedback (PDF) based voltage controller is implemented for effective operation of DVR under voltage disturbances. Response of DVR primarily depends upon its controller action. This paper address the issues in conventional P and PI multiloop controller with and without feedforward path then proposes PDF control strategy for DVR. Using proposed controller, dynamic performance of DVR is improved. The efficacy of proposed controller is illustrated by comparative study with conventional P and PI controller using time response and relative stability analysis. Finally, PSCAD simulation studies for a 10 kV medium voltage DVR and experimental results using a low voltage laboratory prototype DVR are presented to prove robustness of proposed controller for DVR under symmetric and asymmetric voltage sags.

1 December 2018
Verified
Conference Paper
Closed access
KAKarthikeyan Anbalagan
Karthikeyan Anbalagan
DKD.G. Abhilash Krishna
D.G. Abhilash Krishna
ATA Tejaswini
A Tejaswini
APAeshwrya Sweta Panda
Aeshwrya Sweta Panda
RPR Laxmi Prasanna
R Laxmi Prasanna
In this paper the enhancement of power quality related issue is dealt by using Dynamic Voltage Restorer (DVR). There are mainly two aspects with DVR injection voltages one is reference generation and the other is control of DVR. Under unbalanced grid conditions negative sequence components will appear in the grid voltage and causes continuous oscillations in the estimated dq - voltages, which makes sag detection difficult with conventional SRF-PLL. In this paper Double Second Order Generalized Integrator (DSOGI) prefilter based PLL is used for extracting the symmetrical components of grid voltage and further mitigate the harmonic ripple in estimated dq quantities. Further a Pseudo Derivative Feedback (PDF) controller is proposed for single loop voltage feedback control for DVR. The robustness of the proposed controller is verified through comparative studies with PI controller using time response analysis. It is observed that the proposed PDF controller improves the system dynamics i.e., eliminates oscillations and overshoot compared to PI controller. MATLAB/SIMULINK platform is used to perform simulation studies for the 10 kV system subjected to different disturbances viz balanced and unbalanced voltage sags for both PI and PDF based controller. Finally, the experimental studies are carried out for low voltage DVR of 0.5 kVA, 100 V laboratory prototype.

1 December 2018
Verified
Conference Paper
Closed access
KAKarthikeyan Anbalagan
Karthikeyan Anbalagan
DKD G Abhilash Krishna
D G Abhilash Krishna
CNC. Nagamani
C. Nagamani
This paper proposes a Downstream Fault Current Limiter (DFCL) for DVR during downstream faults. It Is based on the concept of Virtual Impedance (VI) which introduces the impedance in series to the system to suppress the large fault currents in the line. In the present work no additional equipment is involved for limiting the fault current and DVR itself is controlled such that FCL operation is ensured. The proposed VI based FCL features flexible implementation and can effectively suppress the fault current during the downstream faults and thereby the DVR is protected along with restoration of PCC voltages. Simulation studies are performed for 10 kV system using PSCAD/EMTDC platform and respective results are presented which proves the feasibility and efficacy of the proposed FCL.

1 December 2017
Verified
Conference Paper
Closed access
KAKarthikeyan Anbalagan
Karthikeyan Anbalagan
DKD.G. Abhilash Krishna
D.G. Abhilash Krishna
SKSushant Kumar
Sushant Kumar
CNC. Nagamani
C. Nagamani
Voltage sags are considered as important power quality problems and the Dynamic Voltage Restorer(DVR) is an effective solution to mitigate the sags and other power quality problems related to voltage. The DVR involves two major aspects: (i) reference generation and (ii) control algorithm. Under unbalanced grid conditions the presence of negative sequence components in the grid voltage causes sustained oscillations in the estimated dq- voltages, which makes sag detection difficult with conventional SRF-PLL and there by chances of controller malfunctioning. In this paper, a Delayed Signal Cancellation (DSC) pre-filter based Positive and Negative Sequence Extractor (PNSE) is employed to extract the Instantaneous Symmetrical Components (ISC) of the grid voltage and filter out the harmonic voltages from the estimated dq-voltages. As the response of the DVR mainly depends on the controller action this paper presents an multiloop PI feed forward controller for enhancing the operation of DVR under distorted grid conditions. The efficacy of the proposed controller is illustrated by comparative study with multiloop feed forward P controller using time response and relative stability analysis. Simulation studies are performed in PSCAD/EMTDC for a 10kV medium voltage DVR under various voltage disturbances such as symmetric and asymmetric voltage sags.

1 October 2018
Verified
Conference Paper
Closed access
KAKarthikeyan Anbalagan
Karthikeyan Anbalagan
PKPrabhakaran K K
Prabhakaran K K
DKD G Abhilash Krishna
D G Abhilash Krishna
CNC Nagamani
C Nagamani
This paper proposes a standalone singe stage PV fed air cooler which consists of two motors (fan blower and water pump). The proposed system comprises of PV source, reduced switch inverter and two PMSM drive. The proposed system aims at reducing the switching losses and overall cost by using reduced switch inverter. The reduced switch inverter uses only eight switches whereas the conventional VSI utilizes twelve switches. In the proposed scheme, blower and pump are independently controlled using field oriented control scheme where speed reference is obtained using Perturb and Observe (P&O) technique. Simulation studies for the proposed PV fed two 400 W PMSM driven blower and pump is performed using MATLAB platform and respective results are presented to show the efficacy of the system.