1 December 2017 in Science Advances
Compressive 3D ultrasound imaging is possible with only one sensor and a simple aperture coding mask.
1 June 2020 in Journal of Controlled Release
Ultrasound insonification of microbubbles can locally increase vascular permeability to enhance drug delivery. To control and optimize the therapeutic potential, we need to better understand the underlying biological mechanisms of the drug delivery pathways. The aim of this in vitro study was to elucidate the microbubble-endothelial cell interaction using the Brandaris 128 ultra-high-speed camera (up to 25 Mfps) coupled to a custom-built Nikon confocal microscope, to visualize both microbubble oscillation and the cellular response. Sonoporation and opening of cell-cell contacts by single αVβ3-targeted microbubbles (n = 152) was monitored up to 4 min after ultrasound insonification (2 MHz, 100-400 kPa, 10 cycles). Sonoporation occurred when microbubble excursion amplitudes exceeded 0.7 μm. Quantification of the influx of the fluorescent model drug propidium iodide upon sonoporation showed that the size of the created pore increased for larger microbubble excursion amplitudes. Microbubble-mediated opening of cell-cell contacts occurred as a cellular response upon sonoporation and did not correlate with the microbubble excursion amplitude itself. The initial integrity of the cell-cell contacts affected the susceptibly to drug delivery, since cell-cell contacts opened more often when cells were only partially attached to their neighbors (48%) than when fully attached (14%). The drug delivery outcomes were independent of nonlinear microbubble behavior, microbubble location, and cell size. In conclusion, by studying the microbubble-cell interaction at nanosecond and nanometer resolution the relationship between drug delivery pathways and their underlying mechanisms was further unraveled. These novel insights will aid the development of safe and efficient microbubble-mediated drug delivery.
18 June 2018 in Applied Physics Letters
We present a form of acoustic microscopy, called Structured Ultrasound Microscopy (SUM). It creates a volumetric image by recording reflected echoes of ultrasound waves with a structured phase front using a moving single-element transducer and computational reconstruction. A priori knowledge of the acoustic field produced by the single element allows us to relate the received echoes to a 3D scatter map within the acoustic beam itself, leading to an isotropic resolution at all depths. An aberration mask in front of the acoustic element imposes the phase structure, broadening the beam and breaking the spatial coherence between different voxels at equal acoustic propagation delay, increasing the uniqueness of the reconstruction. By translating the transducer across the 3D volume, we synthetically enlarge the imaging aperture by using multiple overlapping and spatially sparsely sampled measurements to solve for the entire image. In this paper, we explain the SUM technique and demonstrate microscopic imaging at 20 MHz of a 2.3 × 2.3 × 1.2 mm object in water, with an isotropic resolution below 100 μm. The proposed approach allows for wide-field 3D imaging at isotropic microscopic resolution using a small unfocused ultrasound sensor and multiple spatially sparsely sampled measurements. This technique may find applications in many other fields where space is constrained, device simplicity is desired, and wide-field isotropic high-resolution imaging is required.
18 January 2018 in IEEE Transactions on Biomedical Engineering
Objective: Minimally invasive procedures, such as intravascular and intracardiac interventions, may benefit from guidance with forward-looking (FL) ultrasound. In this work, we investigate FL ultrasound imaging using a single-element transducer integrated in a steerable catheter, together with an optical shape sensing (OSS) system. Methods: We tested the feasibility of the proposed device by imaging the surface of a tissue-mimicking (TM) phantom and an ex vivo human carotid plaque. While manually steering the catheter tip, ultrasound A-lines are acquired at 60 Hz together with the catheter shape from the OSS system, resulting in a 2D sparse and irregularly sampled data set. We implemented an adaptive Normalized Convolution (NC) algorithm to interpolate the sparse data set by applying an anisotropic Gaussian kernel that is rotated according to the local direction of the catheter scanning pattern. To choose the Gaussian widths tangential (${\sigma}$t) and normal (${\sigma}$n) to the scanning pattern, an exhaustive search was implemented based on RMSE computation on ultrasound simulated data. Results: Simulations showed that the sparse data set contains only 5 % of the original information. The chosen widths, ${\sigma}$n = 250 μm and ${\sigma}$t = 100 μm, are used to successfully reconstruct the surface of the phantom with a contrast ratio of 0.9. The same kernel is applied successfully to the carotid plaque data. Conclusion: The proposed approach enables FL imaging with a single ultrasound element, mounted on a steerable device. Significance: This principle may find application in a variety of image-guided interventions, such as chronic total occlusion (CTO) recanalization.
1 April 2003 in Ultrasound in Medicine & Biology
WGWillem J van der Giessen
+1
27 January 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
RBRobert H. S. H. Beurskens
Robert H. S. H. Beurskens
+2
Intravascular ultrasound (IVUS) is a well-established diagnostic method that provides images of the vessel wall and atherosclerotic plaques. We investigate the potential for phased-array IVUS utilizing coded excitation (CE) for improving the penetration depth and image signal-to-noise ratio (SNR). It is realized on a new experimental broadband capacitive micromachined ultrasound transducer (CMUT) array, operated in collapse mode, with 96 elements placed at the circumference of a catheter tip with a 1.2- mm diameter. We characterized the array performance for CE imaging and showed that the -6-dB device bandwidth at a 30-V dc biasing is 25 MHz with a 20-MHz center frequency, with a transmit sensitivity of 37 kPa/V at that frequency. We designed a linear frequency modulation code to improve penetration depth by compensating for high-frequency attenuation while preserving resolution by a mismatched filter reconstruction. We imaged a wire phantom and a human coronary artery plaque. By assessing the image quality of the reconstructed wire phantom image, we achieved 60- and 70-μm axial resolutions using the short pulse and coded signal, respectively, and gained 8 dB in SNR for CE. Our developed system shows 20-frames/s, pixel-based beam-formed, real-time IVUS images.