This study uses dynamic hyperpolarized [1-13C]pyruvate magnetic resonance spectroscopic imaging (MRSI) to estimate differences in glycolytic metabolism between highly metastatic (4T1, n = 7) and metastatically dormant (4T07, n = 7) murine breast cancer models. The apparent conversion rate of pyruvate-to-lactate (kPL) and lactate-to-pyruvate area-under-the-curve ratio (AUCL/P) were estimated from the metabolite images and compared with biochemical metabolic measures and immunohistochemistry (IHC). A non-significant trend of increasing kPL (p = 0.17) and AUCL/P (p = 0.11) from 4T07 to 4T1 tumors was observed. No significant differences in tumor IHC lactate dehydrogenase-A (LDHA), monocarboxylate transporter-1 (MCT1), cluster of differentiation 31 (CD31), and hypoxia inducible factor-α (HIF-1α), tumor lactate-dehydrogenase (LDH) activity, or blood lactate or glucose levels were found between the two tumor lines. However, AUCL/P was significantly correlated with tumor LDH activity (ρspearman = 0.621, p = 0.027) and blood glucose levels (ρspearman = −0.474, p = 0.042). kPL displayed a similar, non-significant trend for LDH activity (ρspearman = 0.480, p = 0.114) and blood glucose levels (ρspearman = −0.414, p = 0.088). Neither kPL nor AUCL/P were significantly correlated with blood lactate levels or tumor LDHA or MCT1. The significant positive correlation between AUCL/P and tumor LDH activity indicates the potential of AUCL/P as a biomarker of glycolytic metabolism in breast cancer models. However, the lack of a significant difference between in vivo tumor metabolism for the two models suggest similar pyruvate-to-lactate conversion despite differing metastatic potential.
Intensity modulated radiation therapy (IMRT) is performed on a regular basis in the clinic to create complex radiation fields to treat cancer, but it has not been implemented in microradiotherapy (mRT) for preclinical systems. A multileaf collimator (MLC) is an integral part of a radiotherapy system that allows IMRT application. Presented here is the development of a key component of an open source mRT system for preclinical research. We have designed and fabricated a binary micro multileaf collimator (bmMLC) for mRT that can provide 1 mm or better resolution at isocenter and attenuate over 98% of a 250 kVp X-ray beam. This is the smallest collimator system designed for RT systems, with 20 brass leaves, each 0.5 mm thick, creating a physical field opening of 1 cm × 1 cm. The mode of actuation for the leaves was rotational, rather than linear, which is typical in larger clinical RT systems. The design presented here met the identified design requirements and represents a rigorous design process, during which several less successful designs were investigated and eventually discarded. After the fabrication of the design, dosimetric characteristics were tested and requirements were met. The final bmMLC designs and technical documents are made available as open-source.
Cerebral aneurysm clips are biomedical implants applied by neurosurgeons to re-approximate arterial vessel walls and prevent catastrophic aneurysmal hemorrhages in patients. Current methods of aneurysm clip production are labor intensive and time-consuming, leading to high costs per implant and limited variability in clip morphology. Metal additive manufacturing is investigated as an alternative to traditional manufacturing methods that may enable production of patient-specific aneurysm clips to account for variations in individual vascular anatomy and possibly reduce surgical complication risks. Relevant challenges to metal additive manufacturing are investigated for biomedical implants, including material choice, design limitations, postprocessing, printed material properties, and combined production methods. Initial experiments with additive manufacturing of 316 L stainless steel aneurysm clips are carried out on a selective laser melting (SLM) system. The dimensions of the printed clips were found to be within 0.5% of the dimensions of the designed clips. Hardness and density of the printed clips (213 ± 7 HV1 and 7.9 g/cc, respectively) were very close to reported values for 316 L stainless steel, as expected. No ferrite and minimal porosity is observed in a cross section of a printed clip, with some anisotropy in the grain orientation. A clamping force of approximately 1 N is measured with a clip separation of 1.5 mm. Metal additive manufacturing shows promise for use in the creation of custom aneurysm clips, but some of the challenges discussed will need to be addressed before clinical use is possible.
The small size of Arabidopsis provides both opportunities and difficulties for laboratory research. Large numbers of plants can be grown in a relatively small area making it easy to observe and investigate interesting phenotypes. Conversely, their small size can also make it difficult to obtain large quantities of tissue for investigation using modern molecular techniques. Sowing large numbers of their seed can overcome this; however, their small seed size makes this difficult. Here we present the Vacuum Seed Sowing Manifold (VSSM), a simple device that can be printed using a 3D printer and provides a new high throughput method to sow large numbers of seeds at a range of densities.