Junbo Zeng

Junbo Zeng

Auto-generated profile, based on publicly available information

Junbo Zeng

Xiamen University, Institute of Artificial Intelligence, Xiamen University, Xiamen, Fujian, 361102, CHINA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2025 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JZJunbo Zeng
Junbo Zeng
YZYudan Zhou
Yudan Zhou
MYMing Ye
Ming Ye
ZWZejun Wu
Zejun Wu
CCCongbo Cai
Congbo Cai
SCShuhui Cai
Shuhui Cai
Objective. This study aims to address the challenge of domain discrepancies between synthetic and real data in quantitative MRI, particularly in multi-parametric mapping using multiple overlapping-echo detachment (MOLED) imaging, which provides rapid and versatile imaging for clinical applications. Approach. A domain adaptation method named MaskedUnet was proposed. Specifically, we employed a mask-based self-supervised pre-training model to learn knowledge from unlabeled real MOLED images. Guided by the learned knowledge of the real data distribution, we regenerated synthetic data closer to the real data distribution to enhance the model’s generalization ability to real data. Evaluations were performed on T 2 and T 2 * MOLED imaging data of two healthy brain volunteers, T 2 and apparent diffusion coefficient (ADC) MOLED imaging data of a healthy brain volunteer, and T 2 and ADC MOLED imaging data of 24 patients with brain tumors from 3T MRI scanners were performed, and the results were compared with existing methods to evaluate the effectiveness of the proposed method. Main results. Experimental results demonstrate the effectiveness of the proposed method for MOLED imaging, significantly reducing noise and eliminating streaking artifacts. The normalized mean square error, peak signal-to-noise ratio and structural similarity index of the reconstructed quantitative maps from our method are 0.2170/0.1624, 18.2492/22.7896 dB, 0.7744/0.8162 respectively for T 2/T 2 * of the healthy participants, 0.2423/0.0893, 17.3168/21.9115 dB, 0.7655/0.8416 respectively for T 2/ADC of the healthy participant, and 0.1344, 21.2407 dB, 0.8333 respectively for ADC of the healthy participant. Significance. MaskedUnet demonstrates the feasibility to bridge the gap between synthetic and real MOLED data, advancing the application of multi-parametric MOLED quantitative imaging.