24 June 2024 in IEEE Transactions on Instrumentation and Measurement
Capacitor voltage transformers (CVTs) are widely used in high-voltage power systems. Their main problem is poor stability in measurement errors. The existing approach of utilizing standard voltage transformers for regular offline error calibration is insufficient in real-time and cannot meet the requirements of intelligent substations for online operations monitoring of key equipment. Therein, this paper proposes a data-driven self-diagnosis method based on metering errors of operational CVTs. This method synchronously collects the secondary signals of three-phase CVT outputs. Firstly, under the rigid constraints of three-phase symmetrical power system operations, the residual subspace parameters that characterize the measurement errors are extracted using principal component analysis (PCA). Then, bilateral threshold detection is combined with a multi-dimensional comprehensive assessment to determine the boundary conditions of the abnormal overall error state of the three-phase CVT and its deterioration direction. Finally, the coded multi-dimensional detection results are input into the learning vector quantized (LVQ) classifier to rapidly diagnose CVT measurement error deterioration. The experimental results show that the proposed method effectively identifies error fluctuations at 0.02% with a detection accuracy for the CVT amplitude error overshoot reaching 0.1%. The method can accurately locate the faulty phases and direction of error deterioration in real-time, realizing the demand for self-diagnosing for CVT metrological errors at the 0.2-level.
28 October 2021 in IEEE Transactions on Instrumentation and Measurement
The poor long-term stability of measurement error is the main problem in the operation of an electronic voltage transformer (EVT). Prevalent methods of error detection involve calibrating it regularly with a standard voltage transformer, but this is not conducive to the timely detection of the degradation in the error of the EVT. In light of this, this article proposes a method to self-detect error based on principal component analysis-wavelet packet decomposition (PCA-WPD). A standard of comparison for error detection is first established based on the characteristics of three-phase symmetrical operation. PCA is then applied to the measurement data of the three-phase EVTs, and their error is mapped to the online process monitoring of squared prediction error (SPE) statistics. Furthermore, the SPE statistics are decomposed by a three-level wavelet packet to eliminate the influence of the time-varying characteristics of node imbalance on the results of detection. The results of experiments show that the proposed method can detect the measurement error with an accuracy of 0.2 class without a standard.
26 May 2025 in IEEE Sensors Journal
Harmonics in power systems not only affect the operational efficiency of equipment but also have the potential to cause system failures and stability issues. Therefore, accurate measurements and analyses of harmonics are of great significance. The conventional fast Fourier transform (FFT) is widely used for harmonic analysis; however, its performance can be affected by issues such as spectral leakage and the fence effect. These issues can result in significant errors in frequency and amplitude estimation, often failing to meet the requirements for high-precision signal processing. To address this challenge, this study proposes a harmonic analysis method based on the self-compensating FFT. After signal preprocessing steps such as windowing and zero-padding, the self-compensating FFT integrates frequency and amplitude correction into a unified framework. It first estimates the frequency deviation using a three-point interpolation method based on the energy distribution of adjacent spectral peaks, and then constructs a data-driven amplitude correction model based on the updated frequency - amplitude relationship. This method improves harmonic analysis accuracy by optimizing frequency and amplitude corrections in tandem, effectively eliminating frequency offset and amplitude errors inherent in the conventional FFT. Experimental results demonstrate that compared to conventional FFT, the self-compensating FFT reduces errors in frequency and amplitude estimation by 99.6%-99.8% and 95%-98%, respectively. These findings demonstrate the significant optimization performance of the proposed method.
1 January 2024 in Review of Scientific Instruments
The measurement error of capacitor voltage transformers (CVTs) has poor stability under the complex environment of substations. Conventionally, error detection is performed by regularly comparing the output of standard transformers, which lacks real-time performance. Moreover, CVTs are prone to operating in an out-of-tolerance state. Thus, this study first analyzes the basic principle of the CVT measurement error self-detection method based on principal component analysis under the constraints of three-phase symmetrical operating characteristics of a power system. Then, the impact of the signal conversion error of analog-to-digital conversion equipment on the self-detection results of CVT measurement errors in engineering applications is analyzed, and a multi-layer wavelet analysis signal denoising method is proposed to enhance the self-detection ability of CVT measurement errors. Finally, simulations show that the proposed method can identify an error change of 0.1%, meeting the self-detection requirements for the measurement error at 0.2 class.
4 October 2024 in IEEE Transactions on Instrumentation and Measurement
Capacitor Voltage Transformers (CVTs) are measurement devices widely used in high-voltage power grids, and the long-term stability of their measurement errors affects the safe operation of power systems. To address the problem of insufficient real-time periodic calibration using standard transformers, this paper proposes an online detection method for CVT measurement error based on enhanced integrated principal component analysis (EIPCA). Considering that the secondary output voltage of CVTs is characterized by a non-stationary random distribution, the method combines the advantages of principal component analysis (PCA) and Kernel Principal Component Analysis (KPCA) to enhance its ability to process mixed linear and nonlinear data. It performs variational mode decomposition (VMD) of the linear residuals mapped in the cascade process to eliminate the modeling error caused by non-stationary data. Finally, the residual component characterizing the integrated error information of the CVT is separated from the primary voltage fluctuation, and the T 2 statistic is established as the index of measurement error detection. The experimental results show that the EIPCA-based online error detection method proposed in this paper can effectively detect the 0.2-level error of the CVT, significantly improving detection performance compared with traditional PCA.
1 August 2025 in Review of Scientific Instruments
As a promising current sensor for high-frequency pulsed current monitoring, printed circuit board (PCB) Rogowski coils demonstrate distinct advantages, including extended bandwidth capability and inherent immunity to magnetic saturation. However, their practical implementation is constrained by an intrinsic trade-off between bandwidth optimization and sensitivity enhancement. To address this challenge, a high-sensitivity, wide-bandwidth current sensor is designed in this paper. Through analysis of the PCB Rogowski coil structure and the distribution parameter model of the coil, an optimal sampling resistance value is selected, and a new type of second-order RC integration circuit is designed. In addition, the effects of integrating resistance, integrating capacitance, the number of turns in the coil, the thickness of the PCB, and the inner and outer diameters of the coil on the operating bandwidth and sensitivity of the sensor are analyzed and investigated to determine the optimal parameters of PCB Rogowski coils and provide a basis for the selection of coil parameters. Finally, a multi-PCB Rogowski coil split-board output method is proposed to improve the sensitivity and measurement accuracy of the sensor while keeping its operating bandwidth unchanged. Simulation and experimental test results show that the multi-PCB Rogowski coil split-board output method can improve the sensitivity and measurement accuracy of the sensor while keeping its operating bandwidth constant.