The earth-air heat exchanger (EAHE) is a sustainable option that allows the electrical energy consumption reduction in buildings. The objective of this study is to evaluate the influence of the incorporation of the thermal energy storage principle based on phase change materials (PCM) into the EAHE on its thermal potential. For this, a three-dimensional numerical model of the PCM coupled to the EAHE (EAHE-PCM) was developed based on the effective heat capacity method and adapted to the climatic conditions and soil characteristics of the Viamão city, Rio Grande do Sul State, Brazil. It was found that for a duct diameter and length of 0.11 m and 25.77 m, the incorporation of PCM to EAHE improved by 8.90% and 3.97% in the average annual thermal potential of heating and cooling, respectively. In addition, the average monthly thermal potential increased 19.70% (heating) and 8.48%(cooling), for the months of May and December, respectively, when the PCM was integrated into the system.
The ground-air heat exchanger (GAHE) represents an eco-friendly solution for improving temperature conditions and, consequently, lowering the power demand in facilities. The aim of this research is to numerically analyze how the length and position of the phase change material (PCM) affect the behavior of the GAHE. To achieve this, a 3D computational simulation of the PCM integrated with the GAHE was employed, utilizing the equivalent heat capacity approach and tailored to the climate and ground properties of southern Brazil. This GAHE-PCM numerical model was created employing the finite volume method through the ANSYS Fluent program. From the obtained results, it was found that for a PCM length of 20.61 m, the incorporation of this material placed from the duct inlet offered an improvement of 13.37% in the average heating energy performance indicator (EPI) in the month of May, in contrast to the EPI value of 18.04% achieved when the PCM was added from the duct outlet.
In the present study, a numerical evaluation of the thermal behavior of Vertical Helical Earth-Air Heat Exchangers (EAHE-VH) installations was conducted under representative climate and soil conditions of the city of Rio Grande, in southern Brazil. The Rectilinear Horizontal Earth-Air Heat Exchanger (EAHE-HR), traditionally employed, was used as a reference. The evaluated geometric variable was the pitch between the helicoids (Ph), and the performance was quantified by the thermal potential of the system, allowing for quantitative comparisons between the different EAHEs through statistical indicators. Comparisons were also made with the Vertical Earth-Air Heat Exchanger with 3 U-shaped ducts (EAHE-V3U). As a result, the option of EAHE-VH with a pitch of 100 mm achieved superior performance of up to 20 % compared to the other helical geometries studied. Additionally, it reached the result closest to the EAHE-HR considered as a reference. When compared to the EAHE-V3U, it showed lower results related to the annual thermal potential. However, it stood out for the need for a smaller volume of soil for its installation, with a reduction of 51.5 % compared to the EAHE-V3U and 79.1 % compared to the EAHE-HR. The multiobjective analysis showed the ability of the EAHE-VH to simultaneously meet the objectives related to thermal potential and required volume for installation, making it the most viable option among the evaluated EAHE construction models when both purposes are equally important.
30 July 2020 in Revista Mundi Engenharia, Tecnologia e Gestão (ISSN: 2525-4782)
O desempenho térmico de uma edificação é um fator importante em habitações quando existe a preocupação com o conforto do usuário, muitas vezes, desconsiderado quando se refere a habitações de interesse social. Uma edificação projetada para o clima no qual está inserida tem maior potencial em fornecer conforto térmico, além de economizar energia. O presente trabalho teve como objetivo avaliar o desempenho térmico, segundo as diretrizes da norma técnica brasileira Edificações Residenciais – Desempenho – NBR 15575/2013, de um conjunto habitacional de interesse social localizado na zona bioclimática 2. A avaliação de desempenho térmico foi realizada através dos procedimentos citados nesta norma: simplificado e simulação computacional. O método simplificado prevê o atendimento a valores limites de transmitância térmica e capacidade térmica da envoltória da edificação, especificamente, paredes externas e cobertura. Para a simulação computacional foi empregado o software EnergyPlus, o qual, a partir de arquivos climáticos e de modelo tridimensional da edificação, é capaz de reproduzir os efeitos do clima sobre a edificação e determinar o comportamento térmico da mesma. Os resultados demonstram que o empreendimento atende à norma NBR 15575/2013, quando empregado o método simplificado, e atinge o desempenho mínimo pelo método de simulação computacional.
Trocadores de Calor Solo-Ar (TCSA) são equipamentos instalados em edificações com o intuito de redução no consumo de energia elétrica com sistemas tradicionais de condicionamento de ar. Seu princípio de operação é simples e consiste em dutos enterrados por onde o ar é forçado a escoar, sendo o solo o responsável por propiciar as trocas térmicas e amenizar a temperatura no ambiente edificado. No presente trabalho é estudado o comportamento de um TCSA em duto reto para três localidades distintas no estado brasileiro do Rio Grande do Sul: Rio Grande, Novo Hamburgo e Ibirubá. Ao final da análise, chegou-se à conclusão que o melhor desempenho foi para a cidade do Rio Grande, com um potencial térmico de aquecimento de 6,51 °C e de resfriamento de 5,95 °C. Além disso, foi possível observar que todas regiões apresentaram resultados considerados satisfatórios quanto ao desempenho térmico.