29 September 2022 in IEEE Journal of Solid-State Circuits
Closed-loop neural interfaces with on-chip machine learning can detect and suppress disease symptoms in neurological disorders or restore lost functions in paralyzed patients. While high-density neural recording can provide rich neural activity information for accurate disease-state detection, existing systems have low channel counts and poor scalability, which could limit their therapeutic efficacy. This work presents a highly scalable and versatile closed-loop neural interface SoC that can overcome these limitations. A 256-channel time-division multiplexed (TDM) front end with a two-step fast-settling mixed-signal DC servo loop (DSL) is proposed to record high-spatial-resolution neural activity and perform channel-selective brain-state inference. A tree-structured neural network (NeuralTree) classification processor extracts a rich set of neural biomarkers in a patient- and disease-specific manner. Trained with an energy-aware learning algorithm, the NeuralTree classifier detects the symptoms of underlying disorders (e.g., epilepsy and movement disorders) at an optimal energy-accuracy tradeoff. A 16-channel high-voltage (HV) compliant neurostimulator closes the therapeutic loop by delivering charge-balanced biphasic current pulses to the brain. The proposed SoC was fabricated in 65-nm CMOS and achieved a 0.227- $\mu \text{J}$ /class energy efficiency in a compact area of 0.014 mm 2/channel. The SoC was extensively verified on human electroencephalography (EEG) and intracranial EEG (iEEG) epilepsy datasets, obtaining 95.6%/94% sensitivity and 96.8%/96.9% specificity, respectively. In vivo neural recordings using soft $\mu $ ECoG arrays and multi-domain biomarker extraction were further performed on a rat model of epilepsy. In addition, for the first time in literature, on-chip classification of rest-state tremor in Parkinson’s disease (PD) from human local field potentials (LFPs) was demonstrated.
31 March 2022 in IEEE Journal of Solid-State Circuits
Next-generation invasive neural interfaces require fully implantable wireless systems that can record from a large number of channels simultaneously. However, transferring the recorded data from the implant to an external receiver emerges as a significant challenge due to the high throughput. To address this challenge, this article presents a neural recording system-on-chip that achieves high resource and wireless bandwidth efficiency by employing on-chip feature extraction. Energy–area-efficient 10-bit 20-kS/s front end amplifies and digitizes the neural signals within the local field potential (LFP) and action potential (AP) bands. The raw data from each channel are decomposed into spectral features using a compressed Hadamard transform (CHT) processor. The selection of the features to be computed is tailored through a machine learning algorithm such that the overall data rate is reduced by 80% without compromising classification performance. Moreover, the CHT feature extractor allows waveform reconstruction on the receiver side for monitoring or additional post-processing. The proposed approach was validated through in vivo and off-line experiments. The prototype fabricated in 65-nm CMOS also includes wireless power and data receiver blocks to demonstrate the energy and area efficiency of the complete system. The overall signal chain consumes 2.6 $\mu \text{W}$ and occupies 0.021 mm 2 per channel, pointing toward its feasibility for 1000-channel single-die neural recording systems.
18 April 2025 in Nature Biomedical Engineering
Individuals with compromised cochlear nerves are ineligible for cochlear implants and instead rely on auditory brainstem implants (ABIs). Most users of ABIs experience sound awareness, which aids in lip reading, yet not speech intelligibility. Here we engineered a dual-site (brainstem and cortex) implantable system, scaled to macaque anatomy, for the analysis of auditory perception evoked by electrical stimulation of the cochlear nucleus. A soft multichannel ABI, fabricated using thin-film processing, provided high-resolution auditory percepts, with spatially distinct stimulation sites eliciting cortical responses akin to frequency-specific tuning. Behavioural responses collected over several months were sufficiently precise to distinguish stimulations from adjacent channels. Soft multichannel ABIs may aid the rehabilitation of individuals with profound hearing loss who are ineligible for cochlear implants.