Shijie Wang

Shijie Wang

Auto-generated profile, based on publicly available information

Shijie Wang

Southeast University,Laboratory of Image Science and Technology,Nanjing,China,210096

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2013 in Medical Physics
Verified
Journal Article
Closed access
PDF file
JWJun Wang
Jun Wang
SWShijie Wang
Shijie Wang
YCYang Chen
Yang Chen
JWJiasong Wu
Jiasong Wu
JCJean-Louis Coatrieux
Jean-Louis Coatrieux
LLLimin Luo
Limin Luo

14 April 2015 in Colloid and Polymer Science
Verified
Journal Article
Closed access
PDF file
XCXiao Cui
Xiao Cui
CQCongde Qiao
Congde Qiao
SWShijie Wang
Shijie Wang
YDYunqiao Ding
Yunqiao Ding
CHChuanming Hao
Chuanming Hao
JLJunying Li
Junying Li

26 March 2010 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
LLLihua Liu
Lihua Liu
BSBao-En Shan
Bao-En Shan
ZTZiqiang Tian
Ziqiang Tian
MSMeixiang Sang
Meixiang Sang
JAJun Ai
Jun Ai
SWShi-Jie Wang
Shi-Jie Wang
Currently, no satisfactory biomarkers are available to screen for esophageal squamous cell carcinoma (ESCC). The goal of this study was to find biomarkers and establish a serum protein fingerprint model for early diagnosis of ESCC using the ClinProt protocol of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Serum samples were collected from 62 patients with ESCC, nine patients with esophageal adenocarcinoma (EA) and 38 healthy individuals. Proteomic spectra of mass to charge ratio (m/z) were generated following the application of plasma to weak cationic-exchanger magnetic beads (WCX-MB). The spectral data were analyzed using a support vector machine, and potential biomarkers were chosen for system training and used to construct diagnostic models. Three differential patterns were established using MALDI-TOF MS. Pattern 1, consisting of 11 protein peaks, separated ESCC patients from the healthy individuals with a sensitivity of 90.0% and a specificity of 88.4%. Pattern 2, consisting of eight protein peaks, separated ESCC in stage I and stage II from stage III and stage IV with a sensitivity of 92.9% and a specificity of 82.3%. Pattern 3, consisting of seven protein peaks, separated ESCC from EA with a sensitivity of 91.3% and a specificity of 80.0%. These results suggested that MALDI-TOF MS combined with MB separation yields significantly higher sensitivity and specificity for the detection of serum protein in patients with ESCC.

1 April 2018 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
PDF file
LJLong-yu Jiang
Long-yu Jiang
WSWenbo Song
Wenbo Song
ZZZhe Zhang
Zhe Zhang
CYChunfeng Yang
Chunfeng Yang
SWShijie Wang
Shijie Wang
PRPhilippe Roux
Philippe Roux
Subspace algorithms based on higher-order cumulants were developed to achieve high-resolution separation in non-Gaussian processes. However, singular value decomposition (SVD) of a huge matrix is an unavoidable step of these algorithms. The memory space and running time required by the decomposition are super-linear with respect to the size of the matrix, which is prohibitive in terms of practical applications. Thus, in this paper, a fast raypath separation algorithm based on low-rank matrix approximation is proposed in a shallow-water waveguide. The experimental results illustrate that the proposed algorithm dramatically reduces the consumption of time and space, with arbitrarily small error, compared to conventional higher-order cumulant-based algorithms.

25 April 2023 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
DSDan Su
Dan Su
FXFei Xu
Fei Xu
HWHeng Wang
Heng Wang
JXJingxue Xie
Jingxue Xie
SWShijie Wang
Shijie Wang
NLNa Liu
Na Liu
A series of reusable polystyrene-supported imidazolium acidic ionic liquid catalysts were synthesized to replace industrial sulfuric acid for the synthesis of bisphenol compounds. These ionic liquids were covalently bonded to the support, reaching a high loading of 1.62–1.80 mmol g−1, respectively. As expected, they achieved a catalytic effect comparable to that of sulfuric acid in the condensation reaction of 9-fluorenone with phenol. Under the optimum reaction parameters, a high yield and high selectivity of 99.9% and 99.7% were achieved for 9,9-bis(4-hydroxyphenyl)fluorene (BHPF). Moreover, this catalyst was also employed for synthesizing other bisphenol compounds and 99.0% conversion of the substrate was achieved. Based on the experimental results and density functional theory (DFT) calculations, a possible reaction mechanism was proposed, which indicated that 9-fluorenone and phenol were simultaneously activated through the synergistic catalysis of anions and cations in a polystyrene-supported ionic liquid catalyst. The recycling experiment results suggested that [PS-PsIm][CF3SO3] maintained a high catalytic activity in five reaction runs, making this a promising catalyst for the synthesis of bisphenol compounds.

23 February 2024 in Chemical Engineering Journal
Verified
Journal Article
Closed access
HWHeng Wang
Heng Wang
FXFei Xu
Fei Xu
WDWeilu Ding
Weilu Ding
SWShijie Wang
Shijie Wang
SZShaojuan Zeng
Shaojuan Zeng
SZSuojiang Zhang
Suojiang Zhang