Kaan Artuc

Kaan Artuc

Auto-generated profile, based on publicly available information

Kaan Artuc

Cavendish Laboratory, University of Cambridge, Cambridge, UK

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2024 in RAS Techniques and Instruments
Verified
Journal Article
Open access
KAKaan Artuc
Kaan Artuc
EAEloy de Lera Acedo
Eloy de Lera Acedo
The cosmic Dark Ages represent a pivotal epoch in the evolution of the Universe, marked by the emergence of the first cosmic structures under the influence of dark matter. The 21-cm hydrogen line, emanating from the hyperfine transition of neutral hydrogen, serves as a critical probe into this era. We describe the development and implementation of the spectrometer for CosmoCube, a novel lunar orbiting CubeSat designed to detect the redshifted 21-cm signal within the redshift range of 13 to 150. Our instrumentation utilizes a Xilinx Radio Frequency System-on-Chip (RFSoC), which integrates both Analog-to-Digital Converters (ADCs) and Digital-to-Analog Converters (DACs), tailored for the spectrometer component of the radiometer. This system is characterized by a 4096 FFT length at 62.5 kHz steps using a Polyphase Filter Bank (PFB), achieving an average Effective Number of Bits (ENOB) of 11.5 bits throughout the frequency of interest, from 10 to 100 MHz. The spectrometer design is further refined through loopback tests involving both DAC and ADC of the RFSoC, with DAC outputs varying between high (+1 dBm) and low (−3 dBm) power modes to characterize system performance. The power consumption was optimized to 5.45 W using three ADCs and one DAC for the radiometer. Additionally, the stability of the ADC noise floor was investigated in a thermal chamber with environmental temperatures ranging from 5 to 40 $^{\circ }$C. A consistent noise floor of approximately −152.5 dBFS/Hz was measured, with a variation of $\pm$0.2 dB, ensuring robust performance under varying thermal conditions.

9 October 2025 in Monthly Notices of the Royal Astronomical Society
Verified
Journal Article
Open access
CKChristian J Kirkham
Christian J Kirkham
WHWill Handley
Will Handley
JZJiacong Zhu
Jiacong Zhu
KAKaan Artuc
Kaan Artuc
IRIan L V Roque
Ian L V Roque
EAEloy de Lera Acedo
Eloy de Lera Acedo
Due to the large dynamic range involved with separating the cosmological 21-cm signal from the Cosmic Dawn from galactic foregrounds, a well-calibrated instrument is essential to avoid biases from instrumental systematics. In this paper, we present three new methods for calibrating a global 21-cm cosmology experiment using the noise wave parameter formalization to characterize a low-noise amplifier including a careful consideration of how calibrator temperature noise and singularities will bias the result. The first method presented in this paper builds upon the existing conjugate priors method by weighting the calibrators by a physically motivated factor, thereby avoiding singularities and normalizing the noise. The second method fits polynomials to the noise wave parameters by marginalizing over the polynomial coefficients and sampling the polynomial orders as parameters. The third method introduces a physically motivated noise model to the marginalized polynomial method. Running these methods on a suite of simulated data sets based on the Radio Experiment for the Analysis of Cosmic Hydrogen receiver design and a lab data set, we found that our methods produced a calibration solution which is equally as or more accurate than the existing conjugate priors method when compared with an estimate of the calibrator’s noise. We find in the case of the measured lab data set the conjugate priors method is biased heavily by the large noise on the shorted load calibrator, resulting in incorrect noise wave parameter fits. This is mitigated by the methods introduced in this paper which calibrate the validation source spectra to within 5 per cent of the noise floor at best.

3 January 2025 in RAS Techniques and Instruments
Verified
Journal Article
Open access
JZJiacong Zhu
Jiacong Zhu
EAEloy de Lera Acedo
Eloy de Lera Acedo
KAKaan Artuc
Kaan Artuc
Xuelei ChenXuelei Chen
Xuelei Chen
The CosmoCube project plans to deploy a global 21-cm spectrometer with 10–100 MHz observation band in a lunar orbit. The farside part of such an orbit, i.e. the part of orbit behind the Moon, offers an ideal site for accurately measuring the 21-cm signal from the dark ages, cosmic dawn, and epoch of reionization, as the effects of the Earth’s ionosphere, artificial radio frequency interference, and complex terrain and soil are all avoided. Given the limitations of a satellite platform, we propose a receiver calibration system design based on a radio frequency system-on-chip, consisting of a vector network analyser (VNA) subsystem, and a source switching subsystem. We introduce the measurement principle of the VNA, and discuss the effect of quantization error. The accuracy, stability, and trajectory noise of the VNA are tested in laboratory experiments. We also present the design of the source-switching subsystem, generating mock data sets, showing that the imperfect return loss, insertion loss, and isolation of surface-mounted microwave switches have a minimal effect on the sky foreground fitting residuals, which are within $\pm 10$ mK under optimal fitting condition. When all possible measurement errors in reflection coefficients and physical temperatures are taken into account, the foreground fitting residuals for the 50–90 MHz part of the spectrum remain around $\pm 20$ mK.

2 June 2026 in Journal of Astronomical Instrumentation
Verified
Journal Article
Closed access
GAG. V. C. Allen
G. V. C. Allen
SPS. Pegwal
S. Pegwal
DVD. I. L. de Villiers
D. I. L. de Villiers
DAD. Anstey
D. Anstey
KAK. Artuc
K. Artuc
JZJ. Zhu
J. Zhu

14 August 2026 in Nature Astronomy
Verified
Journal Article
Closed access
PDF file
EAEloy de Lera Acedo
Eloy de Lera Acedo
DBDavid Bacon
David Bacon
WGWill Grainger
Will Grainger
DADominic Anstey
Dominic Anstey
HBHarry Thomas Jones Bevins
Harry Thomas Jones Bevins
OOOlugbenga Olumodimu
Olugbenga Olumodimu