Qin Zhao

Qin Zhao

Auto-generated profile, based on publicly available information

Qin Zhao

Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health Wuhan University of Science and Technology Wuhan P. R. China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Biochimie
Verified
Journal Article
Closed access
BSBingqing Shui
Bingqing Shui
DTDan Tao
Dan Tao
AFAnca Florea
Anca Florea
JCJing Cheng
Jing Cheng
QZQin Zhao
Qin Zhao
ZGZhenzhong Guo
Zhenzhong Guo

3 January 2022 in Food Chemistry
Verified
Journal Article
Closed access
YZYi-Lian Zhou
Yi-Lian Zhou
SYShi-Wen Yue
Shi-Wen Yue
BCBing-Wei Cheng
Bing-Wei Cheng
QZQin Zhao
Qin Zhao


8 July 2014 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
SXSheng-Nan Xu
Sheng-Nan Xu
QZQin Zhao
Qin Zhao
HHHaibo He
Haibo He
BYBi-Feng Yuan
Bi-Feng Yuan
YFYu-Qi Feng
Yu-Qi Feng
QYQiongwei Yu
Qiongwei Yu
Polypyrrole (PPy)-functionalized Fe3O4 magnetic nanoparticles (Fe3O4–PPy) were prepared and applied as magnetic solid-phase extraction (MSPE) sorbents for the extraction of polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. To achieve the optimal extraction performance, several parameters were investigated, including the amounts of sorbent, volume of desorption solvent, extraction and desorption time, inorganic salt and organic solvent content of the sample matrix. Coupled with gas chromatography/mass spectrometry (GC/MS) analysis, a rapid, sensitive and cost-effective method for the analysis of PAHs in aqueous samples was established. The low detection limits (LODs) for the target PAHs in the proposed method were in the range of 0.38 to 5.01 ng L−1, which are much lower than those LODs reported in previous methods. Good linearity of the detection method was obtained with correlation coefficients (R) between 0.9904 and 0.9992. Satisfactory reproducibility was also achieved with relative standard deviations (RSDs) less than 13.3% by an intra- and inter-day precision evaluation. The recoveries of the 10 PAHs in several environmental water samples ranged from 72.4% to 115.7% with the RSDs being less than 9.7%.

20 May 2022 in Journal of Separation Science
Verified
Journal Article
Closed access
QZQin Zhao
Qin Zhao
SYShi‐Wen Yue
Shi‐Wen Yue
YZYi‐Lian Zhou
Yi‐Lian Zhou
JYJin‐Jie Yang
Jin‐Jie Yang

13 January 2022 in Journal of Separation Science
Verified
Journal Article
Closed access
PDF file
SYShi‐Wen Yue
Shi‐Wen Yue
YZYi‐Lian Zhou
Yi‐Lian Zhou
XPXitian Peng
Xitian Peng
QZQin Zhao
Qin Zhao