Samuel Generoso Dias

Samuel Generoso Dias

Auto-generated profile, based on publicly available information

Samuel Generoso Dias

Instituto Federal de Educação, Ciência e Tecnologia de São Paulo (IFSP), Campus São Carlos, São Carlos, Brazil

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2020 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
BMBruna Juliana Moreira
Bruna Juliana Moreira
LSLetícia Aparecida Schiave
Letícia Aparecida Schiave
RMRoberto Martinez
Roberto Martinez
SDSamuel Generoso Dias
Samuel Generoso Dias
CGCristiane Masetto de Gaitani
Cristiane Masetto de Gaitani
A new method, simple and fast, for fluconazole (FLU) quantification in cerebrospinal fluid (CSF) samples using dispersive liquid–liquid microextraction (DLLME) and an eco-friendly mobile phase for HPLC-PDA was developed. The study of DLLME extraction condition covered the investigation of 12 combinations of extraction and disperser solvents followed by a fractional factorial design 2(7−3) to determine the influence of seven factors. After this stage, a central composite design was performed for three factors and a response surface was obtained. Aiming a compromise between a good recovery and a low organic solvent use it was established an extraction condition that consists of: 100 μL of chloroform, 100 μL of isopropyl alcohol, 200 μL of CSF, 200 μL of 50 mM phosphate buffer pH 7.3 and centrifugation for 5 min at 2200g and 4 °C. The HPLC analysis used an Ascentis® Express C18 column (100 mm × 4.6 mm, 2.7 μm) and an Ascentis® Express C18 guard column (3 mm × 4.6 mm, 2.7 μm), ethanol : water (15 : 85, v/v) as mobile phase, temperature of 45 °C, flow rate of 0.8 mL min−1 and phenacetin as internal standard. The method validation was performed according to European Agency's Guideline on Bioanalytical Validation Methodology and a linear range was obtained from 0.25 to 62.5 μg mL−1, with precision and accuracy within the recommended limits and recovery of 70% for FLU and 81% for phenacetin. Samples were stable in the studies performed and the method showed to be selective and with no carryover effect. The feasibility of the obtained method was confirmed by FLU determination at a CSF from a patient who was treated for neuromycosis. Therefore, here is described a method that meets many principles of green analytical chemistry and is useful for FLU therapeutic monitoring.