18 August 2008 in Optics Express
This paper presents work aimed at optimizing the fabrication of silicon nitride SixNy thin-film visible-light planar waveguides using plasma-enhanced chemical vapour deposition (PECVD). The effects of plasma frequency, precursor gas ratio, and thermal annealing in relation to waveguide optical properties (refractive index, propagation losses) are studied. Experimental results over a wide range of precursor gas ratios show convincingly that waveguides fabricated using low-frequency PECVD have lower propagation losses in the visible range compared to waveguides of equal refractive index fabricated with high-frequency PECVD.
1 February 2009 in Biosensors and Bioelectronics
1 November 2012 in Sensors and Actuators B: Chemical
23 June 2020 in Nano Letters
Nanopillars have been shown to mechanically damage bacteria, suggesting a promising strategy for future antibacterial surfaces. However, the mechanisms underlying this phenomena remain unclear, which ultimately limits translational potential toward real-world applications. Using real-time and end-point analysis techniques, we demonstrate that in contrast to initial expectations, bacteria on multiple hydrophilic “mechano-bactericidal” surfaces remained viable unless exposed to a moving air–liquid interface, which caused considerable cell death. Reasoning that normal forces arising from surface tension may underlie this mechano-bactericidal activity, we developed computational and experimental models to estimate, manipulate, and recreate the impact of these forces. Our experiments together demonstrate that a critical level of external force acting on cells attached to nanopillar surfaces can rapidly deform and rupture bacteria. These studies provide fundamental physical insight into how nanopillar surfaces can serve as effective antibacterial materials and suggest use-conditions under which such nanotechnology approaches may provide practical value.
3 November 2009 in Lab on a Chip
This article presents a device incorporating surface plasmon resonance (SPR) sensing and surface acoustic wave (SAW) actuation integrated onto a common LiNbO3 piezoelectric substrate. The device uses Rayleigh-type SAW to provide active microfluidic mixing in the fluid above the SPR sensor. Validation experiments show that SAW-induced microfluidic mixing results in accelerated binding kinetics of an avidin-biotin assay. Results also show that, though SAW action causes a parasitic SPR response due to heat injection into the fluid, a relatively brief relaxation time following the SAW pulses allows the effect to dissipate, without affecting the overall assay response. Since both SPR sensors and SAW transducers can be fabricated simultaneously using low-cost microfabrication methods on a single substrate, the proposed design is well-suited to lab-on-chip applications.
27 February 2009 in Lab on a Chip
We present a hybrid optical filter design that combines interference and absorbing components for enhanced fluorescence detection in miniaturized highly-integrated lab-on-a-chip devices. The filter is designed in such a way that the advantages of each technology are used to offset the disadvantages of the other. The filter is fabricated with microfabrication compatible processes and materials for monolithic integration with microelectronics and microfluidics devices. The particular embodiment of the filter described herein is designed to discriminate fluorescence emission at 650 nm from excitation at 532 nm. The 9-layer interference filter component is fabricated with alternating TiO2 and SiO2 thin-film layers and has an attenuation of −12.6 dB at 532 nm and −0.76 dB at 650 nm. The absorbing filter component is fabricated using a dyed photopolymer (KMPR + Orasol Red) having an attenuation of −32.6 dB at 532 nm and −1.28 dB at 650 nm. The total rejection ratio of the hybrid filter is 43 dB. The filter exhibits very low autofluorescence and performs equally well at off-axis incidence angles.