Toshiya Nanahara

Toshiya Nanahara

Auto-generated profile, based on publicly available information

Toshiya Nanahara

Aichi Institute of Technology, Toyota, Aichi, Japan

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2023 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
YYYasuaki Yamada
Yasuaki Yamada
ATAkihiro Tsusaka
Akihiro Tsusaka
TNToshiya Nanahara
Toshiya Nanahara
KYKazuto Yukita
Kazuto Yukita
The paper examines a minimum short-circuit-ratio (SCR) for a single-inverter infinite-bus system using powervoltage curves. It derives a steady-state equation between the apparent power and terminal voltage of a current-control type inverter. By normalizing the apparent power with short-circuitcapacity and voltage with that of the infinite bus, the equation proves to be determined with a single parameter, which is calculated with the R/X ratio of the looking-back impedance and the power factor of an inverter. The obtained equation gives a theoretical background on SCR as a metric to assess voltage stability. The minimum SCR is then evaluated for the nose of the power-voltage curves while considering constraints on the inverter terminal voltage. The results reveal that the SCR for an inverter with a constant power factor control has to be greater than about 2. If the reactive power of an inverter is controlled in accordance with its output power, the SCR has to be greater than about 1.

1 December 2019
Verified
Conference Paper
Closed access
JIJun Itai
Jun Itai
KKKenichi Kawabe
Kenichi Kawabe
TNToshiya Nanahara
Toshiya Nanahara
In our previous work, we demonstrated effectiveness of a wide area control system using inverter-interfaced renewable energy sources on improvement of transient stability. In the present paper, we further develop the method for controlling active power of variable-speed wind power generation. The method controls active power output of wind power systems by using wide area control system when a fault occurs. The control action is determined in advance to possible faults by a proposed algorithm. Numerical simulation results show that the active power control by the proposed method is more effective than an autonomous active current suppression function for the improvement of the transient stability. In addition, the results indicate that coordinated control of the active and reactive currents using the proposed method has synergistic effects of improving the transient stability.

27 June 2022
Verified
Conference Paper
Closed access
YIYuto Iwasaki
Yuto Iwasaki
THTadashi Hosoe
Tadashi Hosoe
KIKazuki Ikeda
Kazuki Ikeda
TNTsuyoshi Nishitani
Tsuyoshi Nishitani
ATAoi Tanaka
Aoi Tanaka
Yasuyuki GotoYasuyuki Goto
Yasuyuki Goto
Recently, the United Nations Sustainable Development Goals (SDGs) have attracted much attention globally. To help achieve SDG7, “AFFORDABLE AND CLEANENERGY” the authors are conducting research on renewable energy, particularly wind power, which is useful even in un-electrified areas. In this study, we conduct simulations and experiments of a “dynamic switching system of storage batteries” that is suitable for fluctuating wind turbine output conditions by changing the connection method of the storage batteries connected to the wind turbine. The experiment results confirmed that the storage batteries could be charged in accordance with the generator rotational speed by switching the batteries.