Felipe Domingos Lisbôa

Felipe Domingos Lisbôa

Auto-generated profile, based on publicly available information

Felipe Domingos Lisbôa

Santa Catarina State University

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in International Journal of Sports Physiology and Performance
Verified
Journal Article
Closed access
ASAmadeo F. Salvador
Amadeo F. Salvador
RARafael De Aguiar
Rafael De Aguiar
FLFelipe D. Lisbôa
Felipe D. Lisbôa
KPKayo L. Pereira
Kayo L. Pereira
RCRogério S. de O. Cruz
Rogério S. de O. Cruz
FCFabrizio Caputo
Fabrizio Caputo
Although the amount of evidence demonstrating the beneficial effects of ischemic preconditioning (IPC) on exercise performance is increasing, conclusions about its efficacy cannot yet be drawn. Therefore, the purposes of this review were to determine the effect of IPC on exercise performance and identify the effects of different IPC procedures, exercise types, and subject characteristics on exercise performance. The analysis comprised 19 relevant studies from 2000 to 2015, 15 of which were included in the meta-analyses. Effect sizes (ES) were calculated as the standardized mean difference. Overall, IPC had a small beneficial effect on exercise performance (ES = 0.43; 90% confidence interval [CI], 0.28 to 0.51). The largest ES were found for aerobic (ES = 0.51; 90% CI, 0.35 to 0.67) and anaerobic (ES = 0.23; 90% CI, -0.12 to 0.58) exercise. In contrast, an unclear effect was observed in power and sprint performance (ES = 0.16; 90% CI, –0.20 to 0.52). In conclusion, IPC can effectively enhance aerobic and anaerobic exercise performance.

1 May 2017 in Journal of Science and Medicine in Sport
Verified
Journal Article
Closed access
FLFelipe D. Lisbôa
Felipe D. Lisbôa
TTTiago Turnes
Tiago Turnes
RCRogério S.O. Cruz
Rogério S.O. Cruz
JRJoão A.G. Raimundo
João A.G. Raimundo
GPGustavo S. Pereira
Gustavo S. Pereira
FCFabrizio Caputo
Fabrizio Caputo

1 March 2017 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
RCRogério Santos de Oliveira Cruz
Rogério Santos de Oliveira Cruz
KPKayo Leonardo Pereira
Kayo Leonardo Pereira
FLFelipe Domingos Lisbôa
Felipe Domingos Lisbôa
FCFabrizio Caputo
Fabrizio Caputo

1 September 2015 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
FLFelipe D. Lisbôa
Felipe D. Lisbôa
ASAmadeo F. Salvador
Amadeo F. Salvador
JRJoão A.G. Raimundo
João A.G. Raimundo
KPKayo L. Pereira
Kayo L. Pereira
RARafael De Aguiar
Rafael De Aguiar
FCFabrizio Caputo
Fabrizio Caputo
High-intensity interval training applied at submaximal, maximal, and supramaximal intensities for exercising at V[Combining Dot Above]O2max (t95V[Combining Dot Above]O2max) has shown similar adaptation to low-volume sprint interval training among active subjects. Thus, the aim of the present study was to investigate t95V[Combining Dot Above]O2max during 2 different intermittent exercises in the severe-intensity domain (e.g., range of power outputs over which V[Combining Dot Above]O2max can be elicited during constant-load exercise) and to identify an exercise protocol that reduces the time required to promote higher aerobic demand. Eight active men (22 ± 2 years, 72 ± 5 kg, 174 ± 4 cm, 47 ± 8 ml·kg·min) completed the following protocols on a cycle ergometer: (a) incremental test, (b) determination of critical power (CP), (c) determination of the highest constant intensity (IHIGH) and the lowest exercise duration (TLOW) in which V[Combining Dot Above]O2max is attained, and (d) 2 exercise sessions in a randomized order that consisted of a constant power output (CPO) session at IHIGH and a decreasing power output (DPO) session that applied a decreasing work rate profile from IHIGH to 110% of CP. Time to exhaustion was significantly longer in DPO (371 ± 57 seconds vs. 225 ± 33 seconds). Moreover, t95V[Combining Dot Above]O2max (186 ± 72 seconds vs. 76 ± 49 seconds) and O2 consumed (29 ± 4 L vs. 17 ± 3 L) were higher in DPO when compared with the CPO protocol. In conclusion, data suggest that the application of a DPO protocol during intermittent exercise increases the time spent at high percentages of V[Combining Dot Above]O2max.

23 May 2018 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
TTTiago Turnes
Tiago Turnes
RARafael De Aguiar
Rafael De Aguiar
RCRogério Santos de Oliveira Cruz
Rogério Santos de Oliveira Cruz
ASAmadeo Félix Salvador
Amadeo Félix Salvador
FLFelipe Domingos Lisbôa
Felipe Domingos Lisbôa
FCFabrizio Caputo
Fabrizio Caputo

31 October 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TTTiago Turnes
Tiago Turnes
ASAmadeo Félix Salvador
Amadeo Félix Salvador
FLFelipe Domingos Lisbôa
Felipe Domingos Lisbôa
RARafael De Aguiar
Rafael De Aguiar
RCRogério Santos De Oliveira Cruz
Rogério Santos De Oliveira Cruz
FCFabrizio Caputo
Fabrizio Caputo
The focus of the present study was to investigate the effects of a fast-start pacing strategy on running performance and pulmonary oxygen uptake ( ) kinetics at the upper boundary of the severe-intensity domain. Eleven active male participants (28±10 years, 70±5 kg, 176±6 cm, 57±4 mL/kg/min) visited the laboratory for a series of tests that were performed until exhaustion: 1) an incremental test; 2) three laboratory test sessions performed at 95, 100 and 110% of the maximal aerobic speed; 3) two to four constant speed tests for the determination of the highest constant speed (HS) that still allowed achieving maximal oxygen uptake; and 4) an exercise based on the HS using a higher initial speed followed by a subsequent decrease. To predict equalized performance values for the constant pace, the relationship between time and distance/speed through log-log modelling was used. When a fast-start was utilized, subjects were able to cover a greater distance in a performance of similar duration in comparison with a constant-pace performance (constant pace: 670 m±22%; fast-start: 683 m±22%; P = 0.029); subjects also demonstrated a higher exercise tolerance at a similar average speed when compared with constant-pace performance (constant pace: 114 s±30%; fast-start: 125 s±26%; P = 0.037). Moreover, the mean response time was reduced after a fast start (constant pace: 22.2 s±28%; fast-start: 19.3 s±29%; P = 0.025). In conclusion, middle-distance running performances with a duration of 2–3 min are improved and response time is faster when a fast-start is adopted.