Benjamin Berinson

Benjamin Berinson

Auto-generated profile, based on publicly available information

Benjamin Berinson

Institute for Medical Microbiology, Virology and Hygiene, University Medical Center Hamburg-Eppendorf

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2021 in Journal of Clinical Microbiology
Verified
Journal Article
Open access
PDF file
BBBenjamin Berinson
Benjamin Berinson
ABAnna Both
Anna Both
LBLaura Berneking
Laura Berneking
MCMartin Christner
Martin Christner
MLMarc Lütgehetmann
Marc Lütgehetmann
HRHolger Rohde
Holger Rohde
Rapid pathogen characterization from positive blood cultures (BC) can improve management of patients with blood stream infections (BSI). The FilmArray blood culture identification (BCID) assay is a molecular test approved for direct identification of BSI causing pathogens from positive BC. A recently updated version of the panel (BCID2) comprises improved species identification characteristics, and allows for the detection of one ESBL- and several carbapenemase-encoding genes. Here, the clinical performance of the BCID2 assay for species identification in 180 positive BCs was evaluated. BCID2 results were concordant with standard of care (SOC) in 159/180 (88.3%) BCs. 68/74 (91.9%) and 71/74 (96.0%) of all samples growing mono-bacterial, Gram-positive or Gram-negative pathogens, respectively, were identified in agreement with SOC results. Non-concordance was related to the detection of additional pathogens by the BCID2 (n= 4), discrepant species identification (n= 4), or failure of BCID2 to detect on-panel pathogens (n= 1). A number (12/31; 38.7%) of discordant results became evident in poly-microbial BC specimens. BCID2 identified presence of blaCTX-M carrying species in 12 BC specimens, but failed to predict a third-generation cephalosporin resistance in four isolates exhibiting independent cephalosporin-resistance mechanisms. Carbapenem-resistance related to the presence of blaVIM-2 or blaOxa-48-like was correctly predicted in two isolates. In conclusion, BCID2 assay is a reliable tool for rapid BC processing and species identification. Despite inclusion of common ESBL- or carbapenemase-encoding markers, the multifactorial nature of β–lactam resistance in Gram-negative organisms warrants combination of BCID2 with (rapid) phenotypic susceptibility assays.

15 February 2021 in Journal of Antimicrobial Chemotherapy
Verified
Journal Article
Open access
PDF file
BBBenjamin Berinson
Benjamin Berinson
FOFlaminia Olearo
Flaminia Olearo
ABAnna Both
Anna Both
NBNicole Brossmann
Nicole Brossmann
MCMartin Christner
Martin Christner
HRHolger Rohde
Holger Rohde
The emergence of antibiotic-resistant species calls for fast and reliable phenotypic susceptibility testing to adapt clinical management as fast as possible. We assessed the real-life performance of EUCAST rapid antimicrobial susceptibility testing (RAST) and analysed its impact on patient management. RAST was performed on clinical blood cultures containing Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa or Acinetobacter baumannii complex. Categorical agreement with VITEK2 was analysed. A pre-post quasi-experimental observational study was designed to compare antibiotic treatment in sepsis patients in the RAST patient group (n = 51) and a historical control cohort (n = 54). In total, 436 isolates, corresponding to 2314 disc diameters, were measured; 18.4% of these measurements were in the area of technical uncertainty. For the 81.6% categorical results, which could be compared, 94.7% were in agreement, whereas 5.3% of the results were not. In the RAST group, optimal therapy was initiated on the same day as blood culture positivity, while this was the case in the historical group after 24 h. In six cases, RAST allowed for rapid antibiotic escalation. The 30 day mortality rate was lower in the RAST group, although this was not statistically significant. RAST provides a reliable tool to improve clinical management of sepsis patients by providing rapid phenotypic susceptibility data. While not necessarily being an instrument for de-escalation, especially in areas of low prevalence, early detection allows for timely coverage of resistant isolates. Thus, RAST significantly adds to successful antibiotic stewardship programmes.

8 December 2023 in Infection
Verified
Journal Article
Open access
PDF file
MWManuel Wolters
Manuel Wolters
BBBenjamin Berinson
Benjamin Berinson
NDNicole Degel-Brossmann
Nicole Degel-Brossmann
AHArmin Hoffmann
Armin Hoffmann
RBRico Bluszis
Rico Bluszis
MCMartin Christner
Martin Christner
Purpose: Hypertoxigenic Streptococcus pyogenes emm1 lineage M1UK has recently been associated with upsurges of invasive infections and scarlet fever in several countries, but whole-genome sequencing surveillance data of lineages circulating in Germany is lacking. In this study, we investigated recent iGAS isolates from our laboratory at a German tertiary care center for the presence of the M1UK lineage. Methods: Whole-genome sequencing was employed to characterize a collection of 47 consecutive non-copy isolates recovered from blood cultures (21) and tissue samples (26) in our laboratory between October 2022 and April 2023. Results: M protein gene (emm) typing distinguished 14 different emm types, with emm1 (17) being the dominant type. Single-nucleotide polymorphism (SNP) analysis confirmed the presence of all 27 SNPs characteristic for the M1UK lineage in 14 of 17 emm1 isolates. Conclusion: This study has shown for the first time that M1UK is present in Germany and might constitute a driving force in the observed surge of GAS infections. This observation mirrors developments in the UK and other countries and underscores the importance of WGS surveillance to understand the epidemiology of GAS.

13 July 2023 in Journal of Clinical Microbiology
Verified
Journal Article
Open access
BBBenjamin Berinson
Benjamin Berinson
LSLaura Spenke
Laura Spenke
LKLukas Krivec
Lukas Krivec
KTKonstantin Tanida
Konstantin Tanida
ABAnna Both
Anna Both
HRHolger Rohde
Holger Rohde
Pathogen identification is key in septic arthritis. Culture-based techniques are challenging, especially when patients have been pretreated with antibiotics or when difficult-to-culture bacteria are encountered.

16 October 2024 in Journal of Clinical Microbiology
Verified
Journal Article
Open access
BBBenjamin Berinson
Benjamin Berinson
EDEmma Davies
Emma Davies
JTJessie Torpner
Jessie Torpner
LFLinnea Flinkfeldt
Linnea Flinkfeldt
JFJenny Fernberg
Jenny Fernberg
CMChrister Malmberg
Christer Malmberg
Common phenotypic methods for antimicrobial susceptibility testing (AST) of bacteria are slow, labor intensive, and display considerable technical variability. The QuickMIC system provides rapid AST using a microfluidic linear gradient. Here, we evaluate the performance of QuickMIC at four different laboratories with regard to speed, precision, accuracy, and reproducibility in comparison to broth microdilution (BMD). Spiked ( n = 411) and clinical blood cultures ( n = 148) were tested with the QuickMIC Gram-negative panel and compared with BMD for the 12 on-panel antibiotics, and 10 defined strains were run at each site to measure reproducibility. Logistic and linear regression analysis was applied to explore factors affecting assay performance. The overall essential agreement and categorical agreement between QuickMIC and BMD were 95.6% and 96.0%, respectively. Very major error, major error, and minor error rates were 1.0%, 0.6%, and 2.4%, respectively. Inter-laboratory reproducibility between the sites was high at 98.9% using the acceptable standard of ±1 twofold dilution. The mean in-instrument analysis time overall was 3 h 13 min (SD: 29 min). Regression analysis indicated that QuickMIC is robust with regard to initial inoculum and delay time after blood culture positivity. We conclude that QuickMIC can be used to rapidly measure MIC directly from blood cultures in clinical settings with high reproducibility, precision, and accuracy. The microfluidics-generated linear gradient ensures high reproducibility between laboratories, thus allowing a high level of trust in MIC values from single testing, at the cost of reduced measurement range compared to BMD. IMPORTANCE: Increasing antimicrobial resistance underscores the need for new diagnostic solutions to guide therapy, but traditional antimicrobial susceptibility testing (AST) is often inadequate in time-critical diseases such as sepsis. This work presents a novel and rapid AST system with a rapid turnaround of results, which may help reduce the time to guided therapy, possibly allowing early de-escalation of broad-spectrum empirical therapy as well as rapid adjustments to treatments when coverage is lacking.

12 January 2022 in International Journal of Infectious Diseases
Verified
Journal Article
Open access
LBLaura Berneking
Laura Berneking
MHMichaela Haas
Michaela Haas
LFLisa Frielinghaus
Lisa Frielinghaus
BBBenjamin Berinson
Benjamin Berinson
MLMarc Lütgehetmann
Marc Lütgehetmann
HRHolger Rohde
Holger Rohde
Pathogen detection is crucial for diagnosis and targeted therapy in implant-associated bone and joint infections (BJI). Culture-based microbiology regularly fails to identify causative pathogens. This study evaluated the diagnostic accuracy and clinical usefulness of a syndromic panel polymerase chain reaction (spPCR) assay targeting common BJI pathogens in tissue specimens from patients with implant-associated BJI. Results obtained by spPCR assay and a 16S rDNA PCR were compared with results obtained from a standard of care (SOC) culture-based diagnostics, serving as a gold standard. In total, 126 specimens obtained from 73 patients were analyzed. The spPCR assay correctly identified 33/40 culture-positive samples (82.5 %) and was positive in 9/86 (10.5 %) culture-negative samples, resulting in an overall sensitivity of 84.6 % (95% confidence interval [CI] 68.79-93.59%) and specificity of 89.35% (95% CI 80.6-94.81%). The spPCR was more sensitive compared with the 16S rDNA PCR (37.5%). The spPCR identified pathogens in 7/51 (13.7%) SOC-negative patients. Re-evaluation of spPCR results in clinical context suggested their clinical significance. An spPCR assay targeting common pathogens causing implant-associated BJI may help to identify causative agents in culture-negative cases. As false-negative results are possible, spPCR assays appear as an add-on approach for pathogen detection in implant-associated BJI.