Johanna Bluemink

Johanna Bluemink

Auto-generated profile, based on publicly available information

Johanna Bluemink

Department of Radiation Oncology, Catharina Hospital, Eindhoven, The Netherlands

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2023 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
NBNienke Bakx
Nienke Bakx
MSMaurice van der Sangen
Maurice van der Sangen
JTJacqueline Theuws
Jacqueline Theuws
JBJohanna Bluemink
Johanna Bluemink
CHCoen Hurkmans
Coen Hurkmans
• The clinical use of a DL model for radiotherapy treatment planning was evaluated. • 74% of the DL plans did fulfill all clinical goals without adjustments. • After small manual adjustments, 86% of the plans did fulfill all clinical goals. • Manual adjustments did not significantly improve mean heart or lung dose.

6 May 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
SOSilje Skjelsvik Os
Silje Skjelsvik Os
TMTrine Martens
Trine Martens
JBJohanna Bluemink
Johanna Bluemink
MBMartin Buschmann
Martin Buschmann
JCJeltsje S. Cnossen
Jeltsje S. Cnossen
ASAnnelen Schmidt
Annelen Schmidt
Background and purposeAdaptive radiotherapy using a Library of Plans (LoP) is widely applied in locally advanced cervical cancer; however, implementation varies across centers, and discrepancies between planned and delivered dose may occur. This study aims to: (1) investigate LoP practices across EMBRACE II centers; (2) simulate contrasting LoP strategies to quantify their dosimetric impact; and (3) compare planned and delivered doses. Materials and methodsSeven EMBRACE II centers reported their LoP practices. Based on these different approaches, two strategies were selected: a simple approach (two plans plus a backup) and a complex approach (plans at 1-cm increments of fundus motion).These strategies were simulated in two patient cases with 3 cm and 8 cm fundus motion using pre-treatment planning CTs.For each fraction, the selected plan was accumulated on the planning CT to estimate the planned dose. Delivered dose was estimated by recalculating each fraction on daily cone-beam CTs followed by deformable accumulation to the planning CT. ResultsLoP practices varied substantially across the seven EMBRACE II centers. For the patient with 3 cm fundus motion, V43 was reduced by 54 cm³ with the simple approach and 44 cm³ with the complex approach, compared to a non-adaptive strategy.For the 8 cm motion case, reductions were 115 cm³ and 167 cm³, respectively.Planned and delivered accumulated doses agreed at lower dose levels but diverged in high-dose regions.ConclusionBoth LoP approaches reduced dose to organs at risk compared with a non-adaptive approach, with greater plan granularity providing additional benefit in patients with large motion. These findings support incorporating LoP strategy details and motion stratification in future EMBRACE II dose–toxicity analyses.

28 September 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
SOSilje Skjelsvik Os
Silje Skjelsvik Os
TMTrine Martens
Trine Martens
JBJohanna Bluemink
Johanna Bluemink
MBMartin Buschmann
Martin Buschmann
JCJeltsje S. Cnossen
Jeltsje S. Cnossen
THTaran Paulsen Hellebust
Taran Paulsen Hellebust
Background and purposeAdaptive radiotherapy using a Library of Plans (LoP) is widely applied in locally advanced cervical cancer, yet implementation varies across centres. The aim of this study was to document, compare and illustrate variations in LoP practice across EMBRACE II centres and to evaluate the dosimetric impact of different LoP strategies relative to a non-adaptive approach. Another objective was to compare planned and accumulated delivered dose to assess whether discrepancies between these metrics warrant consideration in future dose–toxicity analyses.Materials and methodsSeven EMBRACE II centres reported their LoP practices. We selected the simplest and the most complex strategy and simulated these on planning-CTs for two patients, with modest (3 cm) and large (8 cm) fundus motion. For each fraction the optimal plan was selected, and the accumulated planned dose calculated on the planning-CT. Fraction doses were also recalculated on daily cone-beam-CTs and deformed to the planning-CT to estimate accumulated delivered dose.ResultsFor 3 cm of motion, planned V43 was reduced by 54 cm³ with the simple strategy and 44 cm³ with the complex strategy compared with non-adaptive radiotherapy. For 8 cm of motion, the corresponding reductions were 115 cm³ and 167 cm³. Discrepancies between accumulated planned and delivered doses were most pronounced at higher dose levels.ConclusionLoP implementation varied substantially across EMBRACE II centres. Healthy-tissue sparing depended on both strategy applied and extent of fundus motion. These hypothesis-generating findings support recording strategy-level LoP data in multicentre outcome analyses and require validation in larger cohorts.