Martin Dres

Martin Dres

Auto-generated profile, based on publicly available information

Martin Dres

Keenan Centre for Biomedical Research, Li Ka Shing Knowledge Institute, St. Michael's Hospital, Toronto, Canada

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2018 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
EGEwan C. Goligher
Ewan C. Goligher
MDMartin Dres
Martin Dres
EFEddy Fan
Eddy Fan
GRGordon D. Rubenfeld
Gordon D. Rubenfeld
DSDamon C. Scales
Damon C. Scales
NFNiall D. Ferguson
Niall D. Ferguson
Rationale: Diaphragm dysfunction worsens outcomes in mechanically ventilated patients, but the clinical impact of potentially preventable changes in diaphragm structure and function caused by mechanical ventilation is unknown. Objectives: To determine whether diaphragm atrophy developing during mechanical ventilation leads to prolonged ventilation. Methods: Diaphragm thickness was measured daily by ultrasound in adults requiring invasive mechanical ventilation; inspiratory effort was assessed by thickening fraction. The primary outcome was time to liberation from ventilation. Secondary outcomes included complications (reintubation, tracheostomy, prolonged ventilation, or death). Associations were adjusted for age, severity of illness, sepsis, sedation, neuromuscular blockade, and comorbidity. Measurements and Main Results: Of 211 patients enrolled, 191 had two or more diaphragm thickness measurements. Thickness decreased more than 10% in 78 patients (41%) by median Day 4 (interquartile range, 3–5). Development of decreased thickness was associated with a lower daily probability of liberation from ventilation (adjusted hazard ratio, 0.69; 95% confidence interval [CI], 0.54–0.87; per 10% decrease), prolonged ICU admission (adjusted duration ratio, 1.71; 95% CI, 1.29–2.27), and a higher risk of complications (adjusted odds ratio, 3.00; 95% CI, 1.34–6.72). Development of increased thickness (n = 47; 24%) also predicted prolonged ventilation (adjusted duration ratio, 1.38; 95% CI, 1.00–1.90). Decreasing thickness was related to abnormally low inspiratory effort; increasing thickness was related to excessive effort. Patients with thickening fraction between 15% and 30% (similar to breathing at rest) during the first 3 days had the shortest duration of ventilation. Conclusions: Diaphragm atrophy developing during mechanical ventilation strongly impacts clinical outcomes. Targeting an inspiratory effort level similar to that of healthy subjects at rest might accelerate liberation from ventilation.

1 June 2017 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
MSMichael C. Sklar
Michael C. Sklar
KBKaren E. A. Burns
Karen E. A. Burns
NRNuttapol Rittayamai
Nuttapol Rittayamai
ALAshley Lanys
Ashley Lanys
MRMichela Rauseo
Michela Rauseo
JFJan O. Friedrich
Jan O. Friedrich
Rationale: Spontaneous breathing trials (SBTs) are designed to simulate conditions after extubation, and it is essential to understand the physiologic impact of different methods. Objectives: We conducted a systematic review and pooled measures reflecting patient respiratory effort among studies comparing SBT methods in a meta-analysis. Methods: We searched Medline, Excerpta Medica Database, and Web of Science from inception to January 2016 to identify randomized and nonrandomized clinical trials reporting physiologic measurements of respiratory effort (pressure–time product) or work of breathing during at least two SBT techniques. Secondary outcomes included the rapid shallow breathing index (RSBI), and effort measured before and after extubation. The quality of physiologic measurement and research design was appraised for each study. Outcomes were analyzed using ratio of means. Measurements and Main Results: Among 4,138 citations, 16 studies (n = 239) were included. Compared with T-piece, pressure support ventilation significantly reduced work by 30% (ratio of means [RoM], 0.70; 95% confidence interval [CI], 0.57–0.86), effort by 30% (RoM, 0.70; 95% CI, 0.60–0.82), and RSBI by 20% (RoM, 0.80; 95% CI, 0.75–0.86). Continuous positive airway pressure had significantly lower pressure-time product by 18% (RoM, 0.82; 95% CI, 0.68–0.999) compared with T-piece, and reduced RSBI by 16% (RoM, 0.84; 95% CI, 0.74–0.95). Studies comparing SBTs with the postextubation period demonstrated that pressure support induced significantly lower effort and RSBI; T-piece reduced effort, but not the work, compared with postextubation. Work, effort, and RSBI measured while intubated on the ventilator with continuous positive airway pressure of 0 cm H2O were no different than extubation. Conclusions: Pressure support reduces respiratory effort compared with T-piece. Continuous positive airway pressure of 0 cm H2O and T-piece more accurately reflect the physiologic conditions after extubation.