Ayca Aytac

Ayca Aytac

Auto-generated profile, based on publicly available information

Ayca Aytac

Department of Civil Engineering, Dogus University – Dudullu Campus, Istanbul, Turkey

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2024 in Aquaculture International
Verified
Journal Article
Open access
PDF file
AAAyca Aytac
Ayca Aytac
GKGuluzar Tuna Kelestemur
Guluzar Tuna Kelestemur
MTM. CİHAT TUNA
M. CİHAT TUNA
With the effective use of aerators with low energy cost and high aeration performance, aquaculture areas can be developed and supported. The main objective of this study is to determine the optimal physical parameters of high aeration capacity high head conduits and to ensure low energy costs, thus to present a comprehensive review of its usability for pond aeration. In this study, a high-head gated conduit was used as the aeration unit. After obtaining the design that will maximize the aeration performance of the high-head gated conduit, a prototype model was developed to ensure its effective use in pond aeration. The parameters affecting the performance of this developed aeration system and the corresponding energy cost values were determined. According to the results, the most important parameters affecting the aeration performance are, respectively, flow rate, the opening of the gate, hydrostatic level, and jet plunge angle. In the optimal design, more than three times the unit volume of water circulating in the system is added to the system. The cost value of this operation in terms of energy was measured as 0.10 kWh/m3 air. The developed system was found to have significantly higher energy efficiency values compared to alternatives, based on specific energy consumption data.

29 January 2024 in Journal of Water and Climate Change
Verified
Journal Article
Open access
PDF file
AAAyca Aytac
Ayca Aytac
MDMustafa Sahin Dogan
Mustafa Sahin Dogan
MTM. CİHAT TUNA
M. CİHAT TUNA
Climate change and global warming are expected to affect water resources management and planning, requiring adaptations to changing conditions. Therefore, it is very important, especially for decision-makers, to identify demand deficits due to less water availability with climate change that may occur in the existing water supply system in advance. FEHEM, a hydroeconomic optimization model of the integrated reservoir system of the Upper Euphrates Basin, which is the largest and main basin providing water flow to the Euphrates River, is developed. Using a 45-year historical hydrological dataset, water management and hydroelectric operations are evaluated with a linear programming model at monthly time steps. The effects of climate change on the Upper Euphrates Basin are evaluated under low and high carbon emission scenarios. According to the average of the different climate scenarios studied in the model, the average decrease in flows is 37.5%. With climate change, peak flows will occur about 1–2 months earlier on average. As a result of these hydrological changes, the total amount of energy production in the basin will decrease by about 54% and energy revenue by the same percentage.

29 December 2022 in Water Practice & Technology
Verified
Journal Article
Open access
PDF file
AAAyca Aytac
Ayca Aytac
MTMuhammed Cihat Tuna
Muhammed Cihat Tuna
The flotation process allows particles and oil to separate from wastewater with high efficiency. Therefore, it is widely used in engineering and is a multidisciplinary field of study. In this study, a new generation flotation method is developed as an alternative to conventional flotation methods. Some experiments are conducted to determine the performance of this new system. It is known that the air-demand rate in the flotation process directly improves flotation performance. For this purpose, maximum aeration efficiency and bubble properties in the flotation cell supported by the newly developed head gated conduit are examined. A pilot-scale flotation system is installed for the experimental study. With the help of high resolution and high-speed cameras, parameters such as air bubble density, air bubble size, dead zone volume and penetration depth are determined. In addition, the images recorded during the flotation process are examined with professional image processing techniques. Experimental results showed that the Froude number, jet plunge angle and cell water levels have a significant impact on air-demand in the new system.

1 September 2023 in Journal of Water and Climate Change
Verified
Journal Article
Open access
PDF file
AAAyca Aytac
Ayca Aytac
MTM. Cihat Tuna
M. Cihat Tuna
MDMustafa Sahin Dogan
Mustafa Sahin Dogan
Hydro-economic optimization models are common in hydropower reservoir modeling to aid system operators and planners. In these models, operations are driven by the economic value and constrained by the availability of water. The objective is to either minimize total costs or maximize total benefits. In this study, a hydro-economic optimization model for the integrated reservoir system of the Upper Euphrates Basin, with major tributaries providing water flow to the Euphrates River, is introduced. These model the 10 large-scale reservoirs of the basin with a total installed capacity of 3,255 MW. Water management and hydropower decision-making operations are evaluated with a piecewise linear programming algorithm in monthly time steps using a 45-year historical hydrology between 1971 and 2016. The model aims to maximize hydropower revenue over a long-term time horizon with energy prices varying by month. Reservoir storage and turbine release decisions are optimized for multiple hydropower plants connected in serial or parallel. Hydropower generation, revenue, reservoir storage, capacity ratios and generation reliability results are analyzed. Results show that these hydropower plants generate about 9,481 Gigawatt hour (GWh) of energy with an average turbine capacity use of 36% and obtain a revenue of 620 million $ per year.

13 November 2024 in Aquaculture International
Verified
Journal Article
Closed access
PDF file
EAErdinc Arici
Erdinc Arici
MTM. CİHAT TUNA
M. CİHAT TUNA
AAAyca Aytac
Ayca Aytac
GKGuluzar Tuna Kelestemur
Guluzar Tuna Kelestemur

14 June 2024 in Aquaculture International
Verified
Journal Article
Open access
PDF file
GKGuluzar Tuna Kelestemur
Guluzar Tuna Kelestemur
AAAyca Aytac
Ayca Aytac
MTM. CİHAT TUNA
M. CİHAT TUNA
Dissolved oxygen (DO) concentration in water is one of the most important water quality parameters in rivers, lakes, and reservoirs. The most effective way to increase DO concentration in water is aeration. Conduits with high aeration performance are predicted to significantly increase aeration efficiency. Based on this prediction, the physical parameters affecting the aeration efficiency (E20) of the conduit aeration system were experimentally investigated. The effect of different jet plunge angles, flow rates, hydrostatic levels, Froude numbers, and gate opening rates was investigated to optimize the system for the best ventilation efficiency. As a result, the aeration efficiency (E20) improves with increasing air intake performance at low gate openings, high Froude numbers, and hydrostatic levels. The increase in jet plunge angles and hydrostatic level directly increases the aeration efficiency. The study showed that conduit systems can be an important alternative for pond aeration due to initial investment and operating costs, low energy cost, and high aeration efficiency.