2 June 2022 in Nature Genetics
1 May 2007 in Journal of Magnetic Resonance
12 February 2009 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: There is significant interest in the development of novel noninvasive techniques for the diagnosis of Alzheimer disease (AD) and tracking its progression. Because MR imaging has detected alterations in sodium levels that correlate with cell death in stroke, we hypothesized that there would be alterations of sodium levels in the brains of patients with AD, related to AD cell death. MATERIALS AND METHODS: A total of 10 volunteers (5 with mild AD and 5 healthy control subjects) were scanned with a 20-minute sodium (23Na) MR imaging protocol on a 3T clinical scanner. RESULTS: After normalizing the signal intensity from the medial temporal lobes corresponding to the hippocampus with the ventricular signal intensity, we were able to detect a 7.5% signal intensity increase in the brains of patients with AD (AD group, 68.25% ± 3.4% vs control group, 60.75% ± 2.9%; P < .01). This signal intensity enhancement inversely correlated with hippocampal volume (AD group, 3.22 ± 0.50 cm3 vs control group, 3.91 ± 0.45 cm3; r2 = 0.50). CONCLUSIONS: This finding suggests that sodium imaging may be a clinically useful tool to detect the neuropathologic changes associated with AD.
5 September 2008 in Journal of Magnetic Resonance Imaging
Purpose: To develop a T1ρ‐prepared, balanced gradient echo (b‐GRE) pulse sequence for rapid three‐dimensional (3D) T1ρ relaxation mapping within the time constraints of a clinical exam (<10 minutes), examine the effect of acquisition on the measured T1ρ relaxation time and optimize 3D T1ρ pulse sequences for the knee joint and spine.Materials and Methods: A pulse sequence consisting of inversion recovery–prepared, fat saturation, T1ρ‐preparation, and b‐GRE image acquisition was used to obtain 3D volume coverage of the patellofemoral and tibiofemoral cartilage and lower lumbar spine. Multiple T1ρ‐weighted images at various contrast times (spin‐lock pulse duration [TSL]) were used to construct a T1ρ relaxation map in both phantoms and in the knee joint and spine in vivo. The transient signal decay during b‐GRE image acquisition was corrected using a k‐space filter. The T1ρ‐prepared b‐GRE sequence was compared to a standard T1ρ‐prepared spin echo (SE) sequence and pulse sequence parameters were optimized numerically using the Bloch equations.Results: The b‐GRE transient signal decay was found to depend on the initial T1ρ‐preparation and the corresponding T1ρ map was altered by variations in the point spread function with TSL. In a two compartment phantom, the steady state response was found to elevate T1ρ from 91.4 ± 6.5 to 293.8 ± 31 and 66.9 ± 3.5 to 661 ± 207 with no change in the goodness‐of‐fit parameter R2. Phase encoding along the longest cartilage dimension and a transient signal decay k‐space filter retained T1ρ contrast. Measurement of T1ρ using the T1ρ‐prepared b‐GRE sequence matches standard T1ρ‐prepared SE in the medial patellar and lateral patellar cartilage compartments. T1ρ‐preparedb‐GRE T1ρ was found to have low interscan variability between four separate scans. Mean patellar cartilage T1ρ was elevated compared to femoral and tibial cartilage T1ρ.Conclusion: The T1ρ‐prepared b‐GRE acquisition rapidly and reliably accelerates T1ρ quantification of tissues offset partially by a TSL‐dependent point spread function. J. Magn. Reson. Imaging 2008;28:744–754.
29 June 2020 in Nature Communications
Restoration of coronary blood flow after a heart attack can cause reperfusion injury potentially leading to impaired cardiac function, adverse tissue remodeling and heart failure. Iron is an essential biometal that may have a pathologic role in this process. There is a clinical need for a precise noninvasive method to detect iron for risk stratification of patients and therapy evaluation. Here, we report that magnetic susceptibility imaging in a large animal model shows an infarct paramagnetic shift associated with duration of coronary artery occlusion and the presence of iron. Iron validation techniques used include histology, immunohistochemistry, spectrometry and spectroscopy. Further mRNA analysis shows upregulation of ferritin and heme oxygenase. While conventional imaging corroborates the findings of iron deposition, magnetic susceptibility imaging has improved sensitivity to iron and mitigates confounding factors such as edema and fibrosis. Myocardial infarction patients receiving reperfusion therapy show magnetic susceptibility changes associated with hypokinetic myocardial wall motion and microvascular obstruction, demonstrating potential for clinical translation.
23 April 2010 in Magnetic Resonance in Medicine
Nine asymptomatic subjects and six patients underwent T1ρ MRI to determine whether Outerbridge grade 1 or 2 cartilage degeneration observed during arthroscopy could be detected noninvasively. MRI was performed 2‐3 months postarthroscopy, using sagittal T1‐weighted and axial and coronal T1ρ MRI, from which spatial T1ρ relaxation maps were calculated from segmented T1‐weighted images. Median T1ρ relaxation times of patients with arthroscopically documented cartilage degeneration and asymptomatic subjects were significantly different (P < 0.001), and median T1ρ exceeded asymptomatic articular cartilage median T1ρ by 2.5 to 9.2 ms. In eight observations of mild cartilage degeneration at arthroscopy (Outerbridge grades 1 and 2), mean compartment T1ρ was elevated in five, but in all observations, large foci of increased T1ρ were observed. It was determined that T1ρ could detect some, but not all, Outerbridge grade 1 and 2 cartilage degeneration but that a larger patient population is needed to determine the sensitivity to these changes. Magn Reson Med 63:1376–1382, 2010.