Antonin Prochazka

Antonin Prochazka

Auto-generated profile, based on publicly available information

Antonin Prochazka

Institute of Biophysics and Informatics, 1st Faculty of Medicine, Charles University, Salmovska 1, Prague 2 120 00, Czech Republic

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Technology in Cancer Research & Treatment
Verified
Journal Article
Open access
APAntonin Prochazka
Antonin Prochazka
SGSumeet Gulati
Sumeet Gulati
SHStepan Holinka
Stepan Holinka
DSDaniel Smutek
Daniel Smutek
In recent years, several computer-aided diagnosis systems emerged for the diagnosis of thyroid gland disorders using ultrasound imaging. These systems based on machine learning algorithms may offer a second opinion to radiologists by evaluating a malignancy risk of thyroid tissue, thus increasing the overall diagnostic accuracy of ultrasound imaging. Although current computer-aided diagnosis systems exhibit promising results, their use in clinical practice is limited. One of the main limitations is that the majority of them use direction-dependent features. Our intention has been to design a computer-aided diagnosis system, which will use only direction-independent features, that is, it will not be dependent on the orientation and the inclination angle of the ultrasound probe when acquiring the image. We have, therefore, applied histogram analysis and segmentation-based fractal texture analysis algorithm, which calculates direction-independent features only. In our study, 40 thyroid nodules (20 malignant and 20 benign) were used to extract several features, such as histogram parameters, fractal dimension, and mean brightness value in different grayscale bands (obtained by 2-threshold binary decomposition). The features were then used in support vector machine and random forests classifiers to differentiate nodules into malignant and benign classes. Using leave-one-out cross-validation method, the overall accuracy was 92.42% for random forests and 94.64% for support vector machine. Results show that both methods are useful in practice; however, support vector machine provides better results for this application. Proposed computer-aided diagnosis system can provide support to radiologists in their current diagnosis of thyroid nodules, whereby it can optimize the overall accuracy of ultrasound imaging.

1 January 2019 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
APAntonin Prochazka
Antonin Prochazka
SGSumeet Gulati
Sumeet Gulati
SHStepan Holinka
Stepan Holinka
DSDaniel Smutek
Daniel Smutek

1 September 2016 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
MWMartin Weiszenstein
Martin Weiszenstein
MMMartina Musutova
Martina Musutova
APAndrea Plihalova
Andrea Plihalova
KWKaterina Westlake
Katerina Westlake
MEMoustafa Elkalaf
Moustafa Elkalaf
JPJan Polak
Jan Polak

1 January 2025 in AIMS Medical Science
Verified
Journal Article
Open access
PDF file
APAntonin Prochazka
Antonin Prochazka
JZJan Zeman
Jan Zeman
Ultrasound imaging plays a vital role in evaluating thyroid nodules, aiding in the assessment of malignancy risk, monitoring size progression, and serving as a guiding tool for thyroid nodule biopsies. Computer-aided diagnosis (CAD) systems have emerged to assist in diagnosing thyroid lesions, reducing unnecessary biopsies, and contributing to the overall improvement of diagnostic accuracy. The segmentation process plays a crucial role in CAD systems because it marks the region of interest. If segmentation were sufficiently accurate, then it would improve the entire diagnostic process and bring CAD systems closer to routine clinical practice. As far as we know, there are currently only three publicly available datasets of ultrasound images of the thyroid gland that can be used for the purpose of thyroid nodules segmentation. The Thyroid Digital Image Database (TDID) is a long-standing benchmark dataset but faces limitations due to the data ambiguities. The TN3K dataset is more robust than TDID, and the Thyroid Ultrasound Cine-clip dataset offers recent alternatives. In this paper, we implemented a deep learning segmentation model based on UNet with a ResNet encoder. We trained this model on all available data and evaluated it on the TN3K test set. The achieved results for the Dice score, IoU score, accuracy, precision, and recall were 84.24%, 75.48%, 97.24%, 82.75%, and 88.98%, respectively. These results represent the most advanced state-of-the-art scores compared to previously published studies and demonstrate that UNet with a ResNet encoder has the capability to accurately segment thyroid nodules in ultrasound images.

30 November 2025 in Journal of Biomedical Informatics
Verified
Journal Article
Closed access
APAntonin Prochazka
Antonin Prochazka
JZJan Zeman
Jan Zeman