Wataru Sahara

Wataru Sahara

Auto-generated profile, based on publicly available information

Wataru Sahara

Department of Orthopaedic Surgery, The University of Osaka Graduate School of Medicine, Osaka, Japan

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2006 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
WSWataru Sahara
Wataru Sahara
KSKazuomi Sugamoto
Kazuomi Sugamoto
MMMasakazu Murai
Masakazu Murai
HTHiroyuki Tanaka
Hiroyuki Tanaka
HYHideki Yoshikawa
Hideki Yoshikawa

1 May 2007 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
PDF file
WSWataru Sahara
Wataru Sahara
KSKazuomi Sugamoto
Kazuomi Sugamoto
MMMasakazu Murai
Masakazu Murai
HYHideki Yoshikawa
Hideki Yoshikawa
There have been several reports about the clavicular and acromioclavicular motion, but a precise motion has been unknown. The purpose of this study was to analyze the 3D kinematics of the clavicle and acromioclavicular joint during arm abduction, using 3D MR images obtained by a vertically open MRI. Seven subjects participated in this investigation, which included 14 shoulders. From a seated position, we obtained MR images of their shoulder in seven abducted positions of the arm in the coronal plane. We evaluated the 3D movements of each bone in the shoulder using the volume‐based registration technique, and analyzed the clavicular positions relative to the lung and the scapular positions relative to the clavicle. During arm abduction, the clavicular motion relative to the lung showed 30.6° retraction, 7.3° elevation, and 33.2° posterior axial rotation. During arm abduction, the scapular motion relative to the clavicle showed 15.6° protraction, 21.5° upward rotation, and 22.2° posterior tilting. This study succeeded in describing the 3D clavicular and acromioclavicular motion including the axial rotation of the clavicle, and it revealed that both motions had large degrees of rotations. © 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 25:1243–1249, 2007

1 March 2007 in Clinical Biomechanics
Verified
Journal Article
Closed access
WSWataru Sahara
Wataru Sahara
KSKazuomi Sugamoto
Kazuomi Sugamoto
MMMasakazu Murai
Masakazu Murai
HTHiroyuki Tanaka
Hiroyuki Tanaka
HYHideki Yoshikawa
Hideki Yoshikawa

17 April 2019 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
Kunihiro OkaKunihiro Oka
Kunihiro Oka
HTHiroyuki Tanaka
Hiroyuki Tanaka
KOKiyoshi Okada
Kiyoshi Okada
WSWataru Sahara
Wataru Sahara
AMAkira Myoui
Akira Myoui
TMTsuyoshi Murase
Tsuyoshi Murase
Background: Medical image processing has facilitated simulation of 3-dimensional (3-D) corrective osteotomy, and 3-D rapid prototyping technology has further enabled the manufacturing of patient-matched surgical guides and implants (patient-matched instruments, or PMIs). However, 3-D corrective osteotomy using these technologies has not been the standard procedure. We aimed to prospectively verify the efficacy and safety of PMIs in corrective osteotomy for deformities of the upper extremity. Methods: We enrolled 16 patients with a total of 17 bone deformities in the upper extremity. Eight patients had distal radial malunion; 5, distal humeral malunion; and 3, forearm diaphyseal malunion. All cases underwent 3-D corrective osteotomy with PMIs. The primary end point was the residual maximum deformity angle (MDA), which was calculated from 2 deformity angles—1 on the anteroposterior and 1 on the lateral postoperative radiograph. Secondary end points included the deformity angle on radiographs, 3-D error between the preoperative planning model and the postoperative result, range of motion, grip strength, pain measured with a visual analog scale (VAS), patient satisfaction, and Disabilities of the Arm, Shoulder and Hand (DASH) score. Results: The average MDA significantly improved from 25.5° preoperatively to 3.3° at the final follow-up (p < 0.001). The angular deformity was within 5° in all cases, except for 1 with distal radial malunion who had a higher angle on the anteroposterior radiograph. The error between the correction seen on the postoperative 3-D bone model and the planned correction was <1° and <1 mm. Flexion and extension of the wrist and pronation of the forearm of the patients treated for distal radial malunion improved significantly, and pronation improved for those treated for forearm diaphyseal malunion. The average VAS score, grip strength, and DASH score significantly improved as well. Of the 16 patients, 15 were very satisfied or satisfied with the outcomes. Conclusions: Corrective osteotomy using PMIs achieved accurate correction and good functional recovery in the upper extremity. Although our study was limited to cases without any deformity on the contralateral side, 3-D corrective osteotomy using PMIs resolved treatment challenges for complex deformities in upper extremities. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

1 January 2005 in Acta Orthopaedica
Verified
Journal Article
Open access
SWSahara Wataru
Sahara Wataru
SKSugamoto Kazuomi
Sugamoto Kazuomi
NYNakajima Yoshikazu
Nakajima Yoshikazu
IHInui Hiroaki
Inui Hiroaki
YTYamazaki Takaharu
Yamazaki Takaharu
YHYoshikawa Hideki
Yoshikawa Hideki
Background Anatomy of the humeral head may be of importance for the kinematics of the shoulder joint. We therefore evaluated the three-dimensional morphology of humeral heads. Material and methods We performed three-dimensional morphological analysis of the articular surfaces of 14 humeral heads in the proximal humeri of 7 cadavers. The articular surface was divided into 9 portions, which were in turn equally divided into 3 sections by an angle in supero-inferior and antero-posterior directions. Each portion of the articular surface was fitted to a sphere, and we calculated the radius of the curvature of each portion. Results The mean radius of the superior portion was significantly greater than that of the central portion, and the mean radii of the anterior and posterior portions were significantly less than that of the central portion. Interpretation Our findings lead us to believe that the morphology of the humeral head is of importance for the kinematics of the shoulder joint.

1 April 2021 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
WSWataru Sahara
Wataru Sahara
TYTakaharu Yamazaki
Takaharu Yamazaki
TITetsuya Inui
Tetsuya Inui
SKShoji Konda
Shoji Konda