The design, simulation, and characterization of a quasioptical system for submillimeter-wave quantification of corneal thickness and water content are presented. The optics operate in the 220-330 GHz band and are comprised of two, custom aspheric, biconvex lenses in a gaussian beam telescope configuration. The design produced broad band wavefront curvature matching to 7.5 mm radius of curvature target surfaces thus emulating a plane-wave-on-planar-media condition and enabling application of stratified medium theory to data analysis. Aspheric lens coefficients were optimized with geometric ray tracing subject to optical path length penalties and physical optics simulations showed aspheric designs achieved wavefront coupling to spherical surfaces, superior to equivalent, canonical hyperbolic lenses. The fabricated lens system was characterized in a planar near-field scanner system and demonstrated good agreement to physical-optics simulations. An average central corneal thickness of 652 $\mu$ m and free water content volume of 47 % were extracted from ex vivo sheep corneal via complex s-parameters and agree with literature values. Extracted contact lens thickness and water content agreed with independently validated values. Moreover, the quasioptical system enabled observation of dynamic changes in artificial tear-film, thickness, and water content. This work elucidates two major findings related to submillimeter-wave wavefront matching on spherical surfaces, with wavelength order radii of curvature: (1) An asphere whose sag coefficients are optimized via field phase variation on a spherical surface produces coupling superior to a plano-hyperbolic lens. (2) For most feasible apertures, the Gaussian beam waist is located in the aperture near field, suggesting consideration for operating in the beam near field.
26 July 2021 in IEEE Transactions on Terahertz Science and Technology
Absolute thickness and free water content gradients in gelatin-based corneal phantoms with physiologically accurate radii of curvature, and aqueous backing were extracted via coherent submillimeter wave reflectometry at 220 330 GHz. Fourier-domain based calibration methods, utilizing temporal and spatial gating, were developed and yielded peak-to-peak amplitude and phase clutter of 10-3 and 0.1, respectively for signal to noise ratios between 40 dB and 50 dB. Twelve phantoms were fabricated. Calibration methods enabled quantification of target sphericity that strongly correlated with optical coherence tomography-based sphericity metrics via image segmentation. Extracted free water volume fraction varied less than 5 % in the 5 phantoms whose fabrication yielded the most spherical geometry. Submillimeter wave-based thickness accuracy was better than 111 m (~/9) with average of 65 m (~/17) and standard deviation of 44 m (~/25) for phantoms with physiologically relevant geometry. Monte Carlo simulations of measurement noise and uncertainty limits agree with experimental data analysis and indicates a lower thickness accuracy limit of 33 m, and water content sensitivities of 0.5 % and 11.8 % for the anterior and posterior segments respectively. Numerical analysis suggests measurement fidelity was SNR limited and identified optical path length ambiguities within the cornea where a continuum of thickness/water gradient pairs produce statistically insignificant differences in complex reflection coefficient for finite SNR. This is the first known submillimeter-wave measurement technique able to extract both the thickness and water content gradients from a soft-tissue phantom, with a water backing, without the need for ancillary measurements.
19 October 2020 in IEEE Transactions on Terahertz Science and Technology
Current state-of-the-art security video cameras operating in the THz regime employ up to a few hundred detectors together with optomechanical scanning to cover an adequate field-of-view for practical concealed object detection. As a downside, the scanning reduces the integration time per pixel compromising sensitivity, increases the complexity, and reduces the reliability of the system. In contrast to this, we demonstrate a video camera, for the first time, basing its operation on the concept of a fully-staring 2D detector array with a single detector element responsible for a single imaged pixel. The imaging system is built around the detector technology of kinetic inductance bolometers, allowing the operation in the intermediate temperature range above 5 K and the scale-up of the detector count into multi-kilo-pixel arrays and beyond. The system is designed for a field-of-view of 2×1 ${m^{2}}$ and an imaging distance of 2.5 m. We describe the main components of the system and show images from concealed object experiments performed at a near-video rate of 9 Hz.
10 June 2021 in IEEE Transactions on Terahertz Science and Technology
This paper presents measurements of the permittivity of gelatin hydrogels between 220 and 330 GHz. Hydrated gelatin was treated as a binary mixture of free water and a compound consisting of water bound to collagen. Submillimeter-wave reflectometry was used to estimate the hydrated gelatin permittivity, hydrated gelatin density, and free-water volume fraction in phantoms composed of 62, 67, 72, and 77% water by weight. A hydrated dry/wet density ratio of 0.335 was validated with optical-coherence tomography. A constant non-freezing bound-water mass of 0.6 g/g was observed and confirmed with differential-scanning calorimetry. Good agreement between results from different modalities supports the dielectric spectroscopy methods and data analysis. Depending on the hydrodynamics at the sample/air interface, measurements indicate a bound-water compound permittivity of 3.77 - j2.52 to 3.95 - j2.49 contrasting the pure-water average permittivity of 5.16 j5.63. The loss related to bound water was much higher than anticipated and characterization will help reduce uncertainty in measurements of gelatin hydrogel-based tissue phantoms; particularly corneal phantoms where adjacent free water creates complex hydration gradients. This is the first known, submillimeter-wave, frequency domain measurement of complex permittivity of the bound-water component in solid, proteinaceous matter.
We present an active THz-imaging technique, which utilizes holographic process in image retrieval. In this technique, information of the target is stored in an interference pattern. The pattern is formed with a reference field and a field reflected from the target. This technique, called indirect holographic imaging, involves only amplitude detection. The image of the target is formed computationally from the complex field given by the holographic process. An experimental imaging system operated at 310 GHz is described. Millimeter-wave images of different targets are presented. The imager performance is described with image signal-to-noise ratio and noise equivalent reflectivity difference, as well as with the cross-range resolution. The indirect holographic imaging method is assessed with variable system signal-to-noise ratios. A knife-edge method is utilized to approximate the point spread function of the imaging system. Cross-range resolution of 0.18° and noise equivalent reflectivity level of 0.002 is achieved with an experimental imager at 310 GHz with 40-cm aperture.
11 November 2022 in IEEE Transactions on Terahertz Science and Technology
The feasibility of a 220 - 330 GHz zero order axicon generated Bessel beam for corneal water content was explored. Simulation and experimental data from the 25-degree cone angle hyperbolic-axicon lens illuminating metallic spherical targets demonstrate a monotonically decreasing, band integrated, backscatter intensity for increasing radius of curvature from 7 – 11 mm, when lens reflector and optical axis are aligned. Further, for radii > = 9.5 mm, maximum signal was obtained with a 1 mm transverse displacement between lens and reflector optical axes arising from spatial correlation between main lobe and out of phase side lobes. Thickness and permittivity parameter estimation experiments were performed on an 8 mm radius of curvature, 1 mm thick fused quartz dome over a 10 mm axial span. Extracted thickness and permittivity varied by less than ∼ 25 μm and 0.2 respectively after correction for superluminal velocity. Estimated water permittivity and thickness of water backed gelatin phantoms showed significantly more variation due to a time varying radius of curvature. To the best of our knowledge, this is the first work that describes axicon generated Bessel beam measurements of layered spheres with varying radii of curvature, in the submillimeter range.