Background: Lateral bony impingement is a major cause of lateral foot pain in progressive collapsing foot deformity (PCFD). Weightbearing computed tomography (WBCT) provides better sensitivity than standard radiographs for detecting impingement. However, many orthopaedic centers have not yet acquired WBCT imaging. This study aimed to (1) investigate the correlation of common radiographic parameters measured on standard weightbearing radiographs with talocalcaneal and calcaneofibular distance assessed with WBCT and (2) establish radiographic cutoff values to detect bony impingement as identified on WBCT. Methods: Ninety-one patients treated for PCFD with standard preoperative radiographs and WBCT were identified. Patients with asymmetric ankle arthritis (talar tilt >2 degrees) were excluded. The talocalcaneal distance at the sinus tarsi and calcaneofibular distance were measured in multiplanar reconstructed WBCT images. Impingement was defined as direct abutment between bones. The relationships between WBCT measurements and 4 common parameters (talonavicular coverage angle [TNC], talo–first metatarsal angle, calcaneal pitch, and hindfoot moment arm [HMA]) in standard radiographs were assessed with Pearson correlations. Receiver operating characteristic curve analysis evaluated the ability of radiographic cutoffs to detect sinus tarsi or calcaneofibular bony impingement, and the area under curve (AUC), sensitivity, specificity, negative and positive predictive value (PPV) were calculated. Results: Talocalcaneal distance narrowing at the sinus tarsi strongly correlated with TNC ( r = 0.64, P < .001), and the calcaneofibular distance narrowing correlated with the HMA moderately yet best among the parameters ( r = 0.55, P < .001). TNC (AUC = 0.837, 95% CI 0.745-0.906) and HMA (AUC=0.959, 95% CI 0.895-0.989) provided the best predictive ability for sinus tarsi and calcaneofibular bony impingement, respectively. A TNC threshold of 41.2 degrees had a 100% PPV for predicting sinus tarsi impingement, whereas an HMA threshold of 38.1 mm had a 100% PPV for calcaneofibular impingement. Conclusion: This study provides evidence that TNC and HMA measurements made on standing radiographs could be used to indicate potential lateral bony impingement in PCFD. Narrowing of talocalcaneal distance best correlated with abduction deformity of the foot, and the narrowing of calcaneofibular distance was best correlated with valgus hindfoot deformity. Level of Evidence: Level III, case control study.
Background: The Trabecular Metal (Zimmer Biomet, Warsaw, IN) total ankle arthroplasty (TAA) system uses a lateral approach with a fibular osteotomy to gain access to the tibiotalar joint and a sagittally curved tibial component. This is the first TAA system to laterally approach the ankle, and few studies have explored outcomes associated with this implant. This study aimed to report the 5-year clinical and radiographic outcomes as well as the survivorship of the implant. Methods: Over a 3-year period, 2 fellowship-trained foot and ankle surgeons used this implant system to treat 38 end-stage arthritic ankles. Reoperation and revision data were collected from all patients (100%) as part of the local prospective database. Patients completed the Foot and Ankle Outcome Score (FAOS) questionnaire preoperatively and at each annual follow-up visit; scores for a minimum of 5 years were available for 28 (73.7%) patients. A radiographic analysis compared postoperative coronal and sagittal alignment in weightbearing radiographs at a minimum of 5 years with that at 3 months postoperatively, as well as cyst or lucency formation, which was available for 21 patients (55.3%). Results: At 5 years, there were 3 revisions (7.9%) and 9 reoperations (23.7%). Reoperations included 4 fibular hardware removal and 5 medial gutter debridement procedures. The FAOS significantly improved for all domains (P < .05). Implant positioning did not significantly change between 3 months and 5 years postoperatively. Conclusion: Our 5-year results in this small series using this unique prosthesis showed good overall survivorship (92.1%) and a reoperation rate of 23.7%, along with clinically significant improvement in patient-reported outcomes. Levels of Evidence: Level IV: Retrospective case series
Background: The Cadence Total Ankle System is a 2-component, fixed-bearing fourth-generation total ankle arthroplasty (TAA) system that was introduced for clinical use in 2016. The purpose of this study was to report non–inventor, non–industry funded survivorship, radiographic and clinical outcomes, and early complications following use of this implant at a minimum of 2 years. Methods: This single-center retrospective study included patients who underwent TAA by 2 surgeons with this novel fixed-bearing system between January 2017 and September 2018. Forty-eight patients were evaluated at an average of 33.6 months. Radiographic outcomes included preoperative and postoperative tibiotalar angle on anteroposterior radiographs of the ankle, sagittal tibial angle (STA) on lateral radiographs of the ankle, and periprosthetic lucency formation and location. Revision and reoperation data were collected, and patient-reported outcomes were assessed using Patient Reported Outcomes Measurement Information System (PROMIS). Subgroup analysis assessed associations between preoperative deformity, postoperative implant alignment, PROMIS scores, and periprosthetic lucency formation. Results: Survivorship of implant was 93.7%, with 3 revisions, 1 due to infection and 2 due to loosening of the implant (1 tibial and 1 talar component). Three patients had reoperations (6.3%): 2 for superficial infection and 1 for gutter debridement due to medial gutter impingement. Fifteen patients (35.8%) developed periprosthetic lucencies, all on the tibial side. PROMIS scores improved after surgery in all domains except Depression. Patients with significant postoperative periprosthetic lucency had worse postoperative PROMIS Physical function scores than patients without lucency ( P < .05). Conclusion: This study demonstrated excellent minimum 2-year clinical and radiographic outcomes and low revision and reoperation rates of this new fourth-generation TAA system. Future studies with longer follow-up, especially on patients with periprosthetic lucency, are necessary to investigate the long-term complications and understand the long-term functional and radiographic outcomes of this implant.
Background: Progressive collapsing foot deformity (PCFD) is recognized as a 3-dimensional deformity centered around the talus. Previous studies have described some features of talar motion in the ankle mortise in PCFD, such as sagging in the sagittal plane or valgus tilt in the coronal plane. However, axial plane alignment of the talus in the ankle mortise in PCFD has not been investigated extensively. The purpose of this study was to examine this axial plane alignment of PCFD vs controls using weightbearing computed tomography (WBCT) images and to determine if talar rotation in the axial plane is associated with increased abduction deformity, as well as to assess the medial ankle joint space narrowing in PCFD that may be associated with axial plane talar rotation. Methods: Multiplanar reconstructed WBCT images of 79 patients with PCFD and 35 control patients (39 scans) were retrospectively analyzed. The PCFD group was divided into 2 subgroups depending on preoperative talonavicular coverage angle (TNC): moderate abduction (TNC 20-40 degrees, n=57) and severe abduction (TNC >40 degrees, n=22). Using the transmalleolar (TM) axis as a reference, the axial alignment of the talus (TM-Tal), calcaneus (TM-Calc), and second metatarsal (TM-2MT) were calculated. Difference between TM-Tal and TM-Calc was calculated to examine talocalcaneal subluxation. A second method to assess talar rotation within the mortise utilized an angle between the lateral malleolus and the talus (LM-Tal) in the axial slices of WBCT. In addition, the prevalence of medial tibiotalar joint space narrowing was assessed. These parameters were compared between the control and PCFD groups, and between moderate and severe abduction groups. Results: The talus was significantly more internally rotated with respect to the ankle TM axis and the lateral malleolus in PCFD patients compared to controls, and in the severe abduction group compared with the moderate abduction group, using both measurement methods. Axial calcaneal orientation did not differ between groups. There was significantly greater axial talocalcaneal subluxation in the PCFD group, and this was also greater in the severe abduction group. The prevalence of medial joint space narrowing was higher in PCFD patients. Conclusion: Our findings suggest that talar malrotation in the axial plane should be considered an underlying feature of abduction deformity in PCFD. The malrotation occurs in both the talonavicular and ankle joints. This rotational deformity should be corrected at the time of reconstructive surgery, especially in cases of severe abduction deformity. In addition, medial ankle joint narrowing was observed in PCFD patients, with a higher prevalence of medial ankle joint narrowing in those with severe abduction. Level of Evidence: Level III, case-control study.
Background: Prior studies on the INBONE II and Salto Talaris total ankle arthroplasty (TAA) systems have reported promising outcomes for both implants. This retrospective study aimed to compare the midterm differences between INBONE II and Salto Talaris TAA. Methods: Between 2007 and 2015, a total of 44 INBONE II consecutive cases and 85 Salto Talaris consecutive cases had minimum 5-year clinical and radiographic follow-up. Preoperative and midterm survivorship, postoperative Foot and Ankle Outcome Score (FAOS), and radiographic measures including tibiotalar alignment (TTA), medial distal tibial angle (MDTA), and sagittal tibial angle (STA) were compared. Results: Survivorship to revision was 97.6% (95% CI, 93.1%-100%) for the INBONE II group and 97% (95% CI, 93%-100%) for the Salto Talaris group ( P = .93). Survivorship to reoperation was significantly different: 95.5% for the INBONE II and 76.4% for Salto Talaris ( P = .021). Postoperative FAOS pain ( P = .01), symptoms ( P = .004), and sports activity ( P = .02) scores were significantly higher in the INBONE II group. The INBONE group had greater preoperative deformity (varus TTA P < .001, valgus TTA P = .02, valgus MDTA P = .005). Conclusion: Although both implants had similar longevity and postoperative alignment, the INBONE II resulted in greater clinical improvement and fewer reoperations than the Salto Talaris at midterm follow-up. Level of Evidence: Level III, retrospective cohort study.
Background: The Infinity Total Ankle Arthroplasty (Stryker, Mahwah, NJ) is a low-profile fixed-bearing implant first introduced in 2014. Although the short-term survivorship (2-4 years follow-up) and complication rates of the Infinity TAA have been reported, there are limited midterm outcome reports. The aim of this study was to describe the survivorship and clinical outcomes of a single-center experience with the Infinity implant at minimum 5-year follow-up. Methods: Retrospective review of 65 ankles that underwent primary total ankle arthroplasty (TAA) with the Infinity implant was conducted. Mean clinical follow-up was 6.5 years (range, 5.0-8.0). Preoperative and postoperative radiographs were measured to assess tibiotalar alignment, periprosthetic lucencies, and cysts. Preoperative, 2-year, and 5-year postoperative Foot and Ankle Outcome Score (FAOS) subscores were compared to assess midterm clinical outcomes. Survivorship assessment was determined by removal of 1 or both metallic implant components. Results: Survivorship of the implant was 93.8% at final follow-up. There were 4 revisions: 2 for tibial implant loosening, 1 for talar loosening, and 1 for loosening of both components. Three of the 4 revisions occurred within the first 2 years following implantation, and the last failure occurred at 7 years postoperatively. There were 11 reoperations in 10 (15%) ankles and 3 wound complications. There were 17 ankles (26.2%) with radiographic abnormalities around the implants, including 14 cases with tibial component lucencies and 4 cases of periimplant cysts. FAOS outcome measurement showed general stability between 2 and 5 years and substantial improvement from preoperative status. Conclusion: To date this study is the largest midterm report on the Infinity total ankle prosthesis, with 65 implants at a mean follow-up of 6.5 years. We found good midterm implant survivorship, and patients experienced significant improvements in FAOS outcome scores and radiographic alignment at final follow-up. Level of Evidence: Level III, retrospective cohort study.