1 April 2025 in Review of Scientific Instruments
This study introduces a novel multi-degree-of-freedom (MDOF) piezoelectric motor (PEM) for high precision and a 10 × 10 mm2 large travel range within a rigid and compact structure (33 × 33 × 30 mm3). The motor consists of four piezoelectric tubes (PTs) arranged and mounted parallel to each other to enable controlled movement along both the X and Y axes by using a sawtooth waveform with a time-delay control strategy. The design features a moving plate clamped between two upper and two lower sapphire balls, with the balls supported by CuBe springs, ensuring symmetric and precise movement. Applying individual driving signals to each PT induces bending deformation sequentially in the same direction, followed by simultaneous recovery to the original position, thereby enabling the movement of the moving plate. Experimental results demonstrated that the motor operated effectively at a signal frequency of 150 Hz, with a minimum driving voltage of 18 V required for detectable motion. The motor exhibited the capability to produce step sizes from 0.53 to 6.23 µm with a linear relationship between driving voltage (±30 to ±180 V) and step size, ensuring consistent performance. The hysteresis analysis revealed minimal energy loss, with hysteresis ratios of 5.2% on the X axis and 4.16% on the Y axis, indicating the motor’s high precision and efficiency. Additionally, the motor sustained a load of 120 g while traversing a 10 × 10 mm2 area, and continuous operation for 12 h revealed no significant performance degradation. The compact and reliable design of this novel MDOF PEM holds potential for applications in confined spaces, such as small-bore superconducting magnets, enabling precise large-area atomic resolution imaging and magnetic property measurements.
1 August 2024 in Review of Scientific Instruments
We introduce a novel piezoelectric stepper motor featuring high compactness, rigidity, and any direction operability. Here, not only is the structure of high novelty but also the working principle very simple. The piezo stacks unit is sandwiched between two spring finger pieces, with almost equal clamping forces applied between the top of the piezo stacks’ unit and the spring finger piece. Applying individual driving signals to each of the five piezo stack pairs, causing deformation one by one in the same direction, followed by simultaneous recovery in the reverse direction, enables movement of the frame part. The optimized clamping force of the piezoelectric stack units and spring fingers ensures maximum output force. The motor’s operational capability at low threshold voltages, specifically 8 V for downward movement and 10 V for upward movement, confirmed its efficacy in both vertical and horizontal directions. The motor’s operational capability at a low threshold voltage of 10 V confirmed its efficacy in both vertical and horizontal directions. At room temperature, step size ranges from 0.3 to 7.4 µm at 20 Hz frequency and varying driving voltage from 10 to 180 V. It has a maximum travel range of about 5 mm and can lift a maximum load of 220 g in an upward direction, so the maximum output force generated by this motor is 2.2 N. The compact and rigid design is capable of building an atomically resolved scanning probe microscope, and its working ability has the potential to use the cleavage of different types of samples in limited space environments, such as the small-bore superconducting magnet and low temperature.
1 September 2025 in Review of Scientific Instruments
This work presents the design and construction of a novel ultra-compact piezoelectric motor (PM) that employs a miniaturized piezoelectric tube (PT) measuring 8 mm in length and 3.65 mm in outer diameter. The PT is externally coupled with a curved copper-beryllium (CuBe) spring and a sapphire shaft guided by a zirconia rail to achieve precise linear motion control. The structural design employed the high hardness and wear resistance of sapphire, along with the low-friction properties of zirconia, to ensure precise linear motion and long-term durability. Operating on the inertial stick–slip principle, the PM utilized a modified sawtooth voltage waveform to induce controlled lateral bending of the PT. The spring transmitted motion to the shaft during slow deformation and allowed relative slip during rapid retraction. Experimental results revealed step sizes ranging from 0.1 to 0.8 μm, a threshold voltage of 45 V, and excellent long-term stability (±15 nm drift over 15 h). The design effectively held small loads with high stability, making it well suited for coarse positioning applications. Its compact footprint, simplified assembly, and bidirectional control capabilities underscore its potential for integration into coarse approach mechanisms of scanning tunnel microscopes and other high-resolution instrumentation platforms where space constraints, accuracy, and long-term reliability are critical. This work lays a foundation for future developments in ultra-compact, non-magnetic, application-specific nanopositioning motors.
3 February 2026 in Measurement Science and Technology
We present an ultra-compact scanning tunneling microscope (STM) head (dimensions: 22.3 × 11.35 × 6.15 mm³) designed to address the growing demand for atomic-scale measurements under extreme conditions where space constraints, mechanical stability, and thermal robustness are critical, such as within the narrow bores (<50 mm) of cryogen-free superconducting magnets and future rotatable STM platforms. The compact form factor is essential for minimizing vibrational coupling, thermal drift, and geometric incompatibilities that limit conventional STM designs in confined cryogenic environments. The instrument is engineered for high-precision nanoscale measurements at cryogenic temperatures and high magnetic fields, incorporating a monolithic sapphire frame optimized via finite element analysis (FEA) to achieve bending-mode eigenfrequencies exceeding 17 kHz, thereby ensuring superior vibration rejection and mechanical stability. A simplified external stick-slip coarse approach mechanism, actuated by a piezoelectric tube (8 mm, Ø3.65 mm) driven by a modified sawtooth waveform, enabled precise tip-sample positioning with minimal mechanical compliance. Key metrological performance metrics include very low room-temperature drift rates of 19.46 ± 1.08 pm/min laterally (XY) and 29.93 ± 1.38 pm/min vertically (Z). At cryogenic temperatures (3 K), drift measurements demonstrated excellent long-term stability, with lateral (XY) and vertical (Z) drift rates of 3.37 ± 0.19 pm/min and 4.85 ± 0.28 pm/min, respectively. The STM’s non-magnetic, low-thermal-expansion materials facilitate reliable operation under extreme conditions, with atomic-resolution imaging and spectroscopy validated on highly oriented pyrolytic graphite (HOPG) for lattice calibration and NbSe₂ for superconducting gap measurements. This instrument addresses critical challenges in nanoscale metrology arising from thermal and vibrational perturbations, providing a modular and scalable platform for traceable, quantitative measurements in highly confined environments, with clear potential for integration into rotatable STM systems.