Lei-Yu Chen

Lei-Yu Chen

Auto-generated profile, based on publicly available information

Lei-Yu Chen

High-Tech Institute of Xian, Xian, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2023 in IEEE Transactions on Aerospace and Electronic Systems
Verified
Journal Article
Closed access
ZZZhijie Zhou
Zhijie Zhou
PZPeng Zhang
Peng Zhang
JWJie Wang
Jie Wang
CZChun-Chao Zhang
Chun-Chao Zhang
LCLei-Yu Chen
Lei-Yu Chen
PNPeng-Yun Ning
Peng-Yun Ning
As an important parameter in the evidential reasoning rule (ER rule), evidence weight has a significant impact on the fusion results. In the existing research, much attentions have been paid on calculating or obtaining weights under different contexts, while the research on the influence and the feasible range of evidence weight is relatively insufficient. In this paper, to reveal the influence of evidence weight and provide guidance for determining acceptable weight range, the impact of evidence weight on the fusion results is evaluated by two evaluation indicators, namely, significant grade and fluctuation coefficient. With the analytical expression of the ER rule, the mapping relationship between weight and fusion results is established in reverse. On the premise of ensuring the effectiveness of fusion results, an optimization model for solving the acceptable weight interval (AWI) is established according to the mapping relationship. The effectiveness of the proposed method is verified by two case studies on both the multiple gyroscopes optimal decision-making and the car selection problem.

10 May 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CZChun-Chao Zhang
Chun-Chao Zhang
ZZZhijie Zhou
Zhijie Zhou
STShuai-Wen Tang
Shuai-Wen Tang
LCLei-Yu Chen
Lei-Yu Chen
PZPeng Zhang
Peng Zhang
For a control system with bus network topology, it is significant while difficult to accurately recognize and locate the fault of the transmission medium. The reason is that the occurrence of one fault can lead to the abnormality of multiple terminal nodes. How to use these abnormal signals to realize effective fault recognition and fault location is the key to solving the problem. Inspired by the manual inference in engineering practice, this article proposes a belief rule-based fault recognition and location model (BR-FRL) for transmission medium in bus network systems. The core idea is fault location based on the results of fault recognition. To adapt to the flexible expansion of bus topology, the designed BR-FRL model has self-organization characteristics. The highlights of this article include three aspects: 1) the progressive reasoning of fault recognition and location based on belief rules is realized in one model; 2) a new model architecture is proposed, which integrates the belief rules, the group method of data handling (GMDH), and the cautious conjunctive rule (CCR); and 3) the parameter learning based on stochastic gradient descent (SGD) is applied to BR-FRL, and the sensitivity analysis of evidence weight in CCR of BR-FRL is performed. The effectiveness of BR-FRL is verified by an experiment on a gigabit-capable passive optical network (G-PON).

30 March 2023 in ISA Transactions
Verified
Journal Article
Closed access
LCLeiyu Chen
Leiyu Chen
ZZZhijie Zhou
Zhijie Zhou
XHXiaoxia Han
Xiaoxia Han
CZChunchao Zhang
Chunchao Zhang
PNPengyun Ning
Pengyun Ning

4 November 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LCLei-Yu Chen
Lei-Yu Chen
ZZZhijie Zhou
Zhijie Zhou
CZChun-Chao Zhang
Chun-Chao Zhang
CLCan Li
Can Li
MCManlin Chen
Manlin Chen
The performance of complex systems is closely related to their security and reliability. Accurate performance evaluation is critical for timely system maintenance. Since the system monitoring information obtained usually contains noise, using this information to evaluate the performance of the device may result in inaccurate results. Interval values are used to represent the uncertainty of the monitoring information containing noise in the case of small samples. The uncertainty in the evaluation results is divided into two categories: the uncertainty of the evaluation model and the uncertainty of the monitoring information. The effects of the two categories on the evaluation results and the monotonicity of the output results on the monitoring information and model parameters are quantitatively analyzed. To avoid the problem of interval expansion during model optimization, an IER optimization model based on the belief degrees of monitoring information is built, and the whole evaluation process is solved and optimized uniformly. The monotonicity analysis results simplify the solving process of the IER optimization model, which reduces the difficulty and complexity. Validity and normalization tests are performed on the belief structure of the evaluation results, eliminating the invalid and redundant parts, and obtaining the best interval range of the evaluation results. The effectiveness of the proposed method is verified by its application in an electric servo mechanism.

12 December 2022 in Entropy
Verified
Journal Article
Open access
PDF file
XZXiangyi Zhou
Xiangyi Zhou
ZZZhijie Zhou
Zhijie Zhou
GHGuanyu Hu
Guanyu Hu
XHXiaoxia Han
Xiaoxia Han
LCLeiyu Chen
Leiyu Chen
It is of great significance to obtain the performance state of complex equipment to protect equipment and maintain its normal operation. The majority of the performance evaluation methods are based on test data, but resume information is not considered. With its wide applicability and completeness, the resume information can be used in the comprehensive evaluation of equipment in various non-testing situations. By incorporating resume information into the performance evaluation of complex equipment, the flexible use of test data and resume information can result in a more comprehensive and accurate evaluation. Therefore, this paper focuses on the evaluation method of complex equipment performance based on evidential reasoning (ER) considering resume information. In order to unify the test data and resume information in the same framework, a novel method is proposed to transform them into the ER-based performance evaluation. On this basis, according to the index types, different reliability calculation methods are put forward, with one being based on the first-order fitting coefficient of variation, and the other being based on average time to failure; the index weight is analyzed based on the method of expert weight construction. Then, the transformed information with reliability and weight are fused by the ER rule. Finally, a performance evaluation case of a certain inertial measurement unit (IMU) is conducted to verify the effectiveness of the proposed method.