Darin F. Ardus

Darin F. Ardus

Auto-generated profile, based on publicly available information

Darin F. Ardus

FSBI «NMRC of cardiology named after academician E.I.Chazov» of the MH RF

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2020 in Russian Journal of Cardiology
Verified
Journal Article
Open access
PDF file
ОСО. В. Сапельников
О. В. Сапельников
DAD. F. Ardus
D. F. Ardus
VKV. S. Kostin
V. S. Kostin
TUT. M. Uskach
T. M. Uskach
DCD. I. Cherkashin
D. I. Cherkashin
RAR. S. Akchurin
R. S. Akchurin
Нефлюороскопический подход к катетерному лечению фибрилляции предсердий

1 January 2021 in Russian Cardiology Bulletin
Verified
Journal Article
Closed access
VKV.S. Kostin
V.S. Kostin
OSO.V. Sapelnikov
O.V. Sapelnikov
TUT.M. Uskach
T.M. Uskach
DCD.I. Cherkashin
D.I. Cherkashin
IGI.R. Grishin
I.R. Grishin
RAR.S. Akchurin
R.S. Akchurin
В настоящее время стандартом интервенционного лечения фибрилляции предсердий (ФП) является катетерная аблация (КА), в частности, криобаллонная аблация (КБА) устьев легочных вен. В рутинной клинической практике процедуру КБА проводят под контролем флюороскопии, что влечет за собой необходимость оснащения операционной рентгеноборудованием и средствами радиологической защиты, и, что самое главное, как пациенты, так и медицинский персонал подвергаются воздействию значительных и потенциально опасных доз ионизирующего излучения. ЦЕЛЬ ИССЛЕДОВАНИЯ Оценить эффективность и безопасность криобаллонной аблации легочных вен без использования флюороскопии по сравнению со стандартной методикой, основанной на применении рентгеновского излучения. МАТЕРИАЛ И МЕТОДЫ В исследование включено 110 пациентов с симптомной пароксизмальной и персистирующей формами ФП, ранее не оперированных методом КА. Пациенты распределены в 2 равные группы. Исследуемая группа (группа A) — 55 человек, оперированных методом КБА с применением трехмерного навигационного картирования (EnSite Precision) и внутрисердечной эхокардиографии (ВСЭхоКГ). Группа сравнения (группа B) — 55 человек, в которой КБА выполняли по стандартной методике с применением флюороскопии. В течение 12 мес продолжалось наблюдение пациентов с определением частоты развития рецидивов нарушений ритма по данным опроса, результатов ЭКГ и мониторирования по Холтеру (ХМЭКГ). РЕЗУЛЬТАТЫ В ходе наблюдения через 6 мес у 12 (21,8%) больных группы A и 10 (18,2%) группы B развились рецидивы аритмии (p=0,81). В течение 12 мес наблюдения у 67,3% больных группы A и 70,9% группы B не отмечены симптомные и документированные пароксизмы ФП (p=0,83). Продолжительность флюороскопии (0,9±0,4 и 14,1±2,67 мин) и доза облучения (8,75±1,7 и 184,5±28,6 мГр) были существенно выше у пациентов группы B (p<0,001). Среднее значение общей продолжительности процедуры КБА в изучаемых группах статистически значимо не различалось (86,3±19,1 и 79,8±19,8 мин, p=0,11). Количество осложнений сопоставимо в обеих группах. ЗАКЛЮЧЕНИЕ Процедура криобаллонной аблации устьев легочных вен без применения флюороскопии по эффективности не уступает криобаллонной аблации, проводимой по стандартной методике с использованием рентгеновского излучения. Положительные результаты в снижении радиационного воздействия, продемонстрированные в нашем исследовании, достигнуты без ущерба для безопасности пациентов.

31 March 2023 in Kardiologiia
Verified
Journal Article
Open access
PDF file
EHE. G. Huseynli
E. G. Huseynli
OSO. V. Sapelnikov
O. V. Sapelnikov
VAV. A. Amanatova
V. A. Amanatova
DAD. F. Ardus
D. F. Ardus
MKM. R. Khachirov
M. R. Khachirov
RAR. S. Akchurin
R. S. Akchurin
Aim      To evaluate a possibility of using radiofrequency catheter ablation guided by intracardiac echocardiography (ICE), its efficacy and safety for treatment of ventricular tachycardia (VT) of various etiology. Material and methods  Catheter intervention was performed for 20 enrolled patients with symptomatic VT. Ablation procedures were guided by a 3D electroanatomical mapping system and ICE. Results Mean duration of the procedure was 201.2±62.5 min. The procedure was successful (non-inducibility of VT) in 100% of cases. None of the patients had postoperative complications. Conclusion      Ablation of VT arrhythmogenic substrate guided by 3D electroanatomical navigational mapping and ICE without X-ray is feasible and safe.

27 June 2023 in Journal of Arrhythmology
Verified
Journal Article
Open access
PDF file
DAD. F. Ardus
D. F. Ardus
TUT. M. Uskach
T. M. Uskach
ОСО. В. Сапельников
О. В. Сапельников
RAR. S. Akchurin
R. S. Akchurin
Current clinical case demonstrates the catheter treatment of longstanding persistent atrial fibrillation and atrial flutter without the use of fluoroscopy in patient with chronic heart failure. The effect on the parameters of heart remodeling, as well as the dynamics of NT-proBNP after 6 months of follow-up is demonstrated.

20 October 2025 in Terapevticheskii arkhiv
Verified
Journal Article
Open access
PDF file
TUTatiana M. Uskach
Tatiana M. Uskach
VAValeria A. Amanatova
Valeria A. Amanatova
DADarin F. Ardus
Darin F. Ardus
OSOleg V. Sapelnikov
Oleg V. Sapelnikov
TITimur E. Imaev
Timur E. Imaev
ТНТерещенко Сергей Николаевич
Терещенко Сергей Николаевич
Currently, the proportion of patients with heart failure is progressively increasing. Despite the progress in drug therapy, additional manipulations are often necessary to correct cardiovascular pathology in these patients. Given the high comorbidity, the use of classical surgical techniques is impossible in some cases. Implantation of high-tech devices, catheter ablation of arrhythmogenic areas, transcatheter mitral valve plastic surgery are minimally invasive surgical methods. Proper interaction between a cardiologist and a cardiovascular surgeon allows for the maximum personalization of the approach to the treatment of each patient, achieving maximum results with significantly reduced risks.

28 April 2025 in Patologiya krovoobrashcheniya i kardiokhirurgiya
Verified
Journal Article
Open access
PDF file
MDM.F. Demurchev
M.F. Demurchev
IGI.R. Grishin
I.R. Grishin
ОСО.в. Сапельников
О.в. Сапельников
SAS.A. Ayvazyan
S.A. Ayvazyan
ISI.N. Sorokin
I.N. Sorokin
RAR.S. Akchurin
R.S. Akchurin
Introduction: Progressive increase in the number of cardiac implanted electronic devices entails an increment of complications, which require the complete removal of the device system in selected cases. Instruments, such as laser sheath and mechanical dilator introduced into the surgical arsenal, significantly improved the removal of devices and increased the success rate of the procedure. Transvenous lead extraction using additional instruments enables the safe extraction of electrodes in most cases, but does not eliminate the risk of complications, the most significant of which is vascular bed perforation. The hybrid approach, combining transvenous lead extraction with thoracoscopic assistance, allows for visual monitoring of each step of the operation to detect intraoperative complications promptly. Objective: The study aimed to investigate the safety and efficacy of different transvenous lead extraction methods. Methods: One-hundred fifty-four patients, who underwent transvenous extraction of cardiac implantable electronic devices in Chazov National Medical Research Center for Cardiology from 2018 to 2024, were included in the study. Transvenous extraction of leads was performed both on infectious and non-infectious indications. Results: Of the 154 surgical procedures performed, 80 (51.9%) were on infectious indications (group 1) and 74 (48.1%) were on non-infectious indications (group 2). The median age of the electrode was 64 months, (from 30 to 144 months). Between one and five electrodes were removed during each surgical procedure, with an average of two electrodes removed per procedure. Simultaneous reimplantation of a new device was performed in 58 (78.3%) of the 74 patients in the group 2.In 68 cases (44%), the method of simple traction on a locking stylet was chosen as a transvenous electrode extraction technique, while additional instrumentation was used in 86 cases (56%). In particular, a mechanical dilator was used in 14 cases (17%), an excimer laser was engaged in 26 cases (30%), and 2 instruments together were used in 25 cases (29%). The number of hybrid interventions with thoracoscopic control amounted to 21 (24%). Complete extraction of the system was achieved in 128 cases (83.2%), and 26 (17.8%) cases were partially successful (residual electrode fragment value >4 cm). Conversion to open surgery was required in 3 (1.9%) of 154 interventions. Conclusion: Transvenous lead extraction using high-tech tools provides an opportunity to improve the success of the operation. Thoracoscopic control opens up the possibilities of intraoperative visualization of anatomical structures to prevent fatal complications. Received 22 August 2024. Revised 1 December 2024. Accepted 15 January 2025. FundingThe study did not have sponsorship. Conflict of interestThe authors declare no conflict of interest. Contribution of the authorsConception and study design: A.A. Shiryaev, R.S. Akchurin, O.V. Sapelnikov, I.R. GrishinData collection and analysis: M.F. Demurchev, D.F. Ardus, M.A. Podyanov, I.R. Grishin, D.I. Cherkashin, K.A. Kosonogov, S.A. Ayvazyan, I.N. SorokinStatistical analysis: M.F. Demurchev, A.V. Vereshchagina, A.V. EmelyanovDrafting the article: M.F. Demurchev, I.R. Grishin, O.V. Sapelnikov, D.F. ArdusCritical revision of the article: K.A. Kosonogov, S.A. Ayvazyan, I.N. SorokinFinal approval of the version to be published: M.F. Demurchev, I.R. Grishin, O.V. Sapelnikov, S.A. Ayvazyan, I.N. Sorokin, K.A. Kosonogov, D.I. Cherkashin, D.F. Ardus, M.A. Podyanov, A.A. Kulikov, A.V. Vereshchagina, A.V. Emelyanov, A.A. Shiryaev, R.S. Akchurin