Sajan K. Sadanandan

Sajan K. Sadanandan

Auto-generated profile, based on publicly available information

Sajan K. Sadanandan

Lane Department of Computer Science and Electrical Engineering, West Virginia University, Morgantown, WV, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2021 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
RSRamyar Saeedi
Ramyar Saeedi
SSSajan K. Sadanandan
Sajan K. Sadanandan
ASAnurag Srivastava
Anurag Srivastava
KDKevin L. Davies
Kevin L. Davies
AGAssefaw Gebremedhin
Assefaw Gebremedhin
A significant amount of distributed photovoltaic (PV) generation is “invisible” to distribution system operators since it is behind the meter on customer premises and not directly monitored by the utility. The generation essentially adds an unknown varying negative demand to the system, which causes additional uncertainty in determining the total load. This uncertainty directly impacts system reliability, cold load pickup, load behavior modeling, and hence cost of operation. Thus, it is essential to create low-complexity localized models for estimating power generation from these invisible sites behind the meters. This article proposes an adaptive machine learning framework to: a) learn using weather data and a minimal number of BTM PV generation measurement sensors, b) forecast PV generation using weather, location of PV, and trained ML model at location for unmeasured BTM PV; c) use estimated PV and net load measured by smart meter or smart transformer to estimate total true load at each time step; and d) learn the specific load patterns eventually to adapt localized models. The proposed framework's core idea is to transform the data such that: a) the machine learning model can effectively utilize the time dependency of measurements; and b) the measurements are transformed into a lower dimensional space to reduce complexity while maintaining accuracy. The transformed measurements are then used to train the machine learning models for load/PV disaggregation. Machine learning models investigated include linear regression, decision tree, random forest (RF), and multilayer perceptron. The proposed framework's efficacy is demonstrated using two datasets, a real dataset from Hawaii and a simulated dataset using detailed models in GridLab-D. Several test/training split scenarios, including 90-10% split, one-month-out, one-season-out, and panel-independent split are presented to provide a thorough evaluation of the proposed framework. Results on both datasets show that the proposed framework can estimate PV generation with high accuracy using low-complexity methods. The accuracy results are comparable to higher complexity models (e.g., deep architectures), and RF is found to provide superior performance with these specific datasets compared to the other ML models investigated.

24 August 2021 in IEEE Access
Verified
Journal Article
Open access
SRSyed Muhammad Hur Rizvi
Syed Muhammad Hur Rizvi
SSSajan K. Sadanandan
Sajan K. Sadanandan
ASAnurag Srivastava
Anurag Srivastava
Short-term voltage stability of power systems is governed by load dynamics, especially the proportion of small induction motors prevalent in residential air-conditioners. It is essential to efficiently monitor short-term voltage stability in real-time by detailed data analytics on voltage measurements acquired from phasor measurement units (PMUs). It is likewise critical to identify the location of faults resulting in short-term voltage stability issues for effective remedial actions. This paper proposes a time-series deep learning framework using 1D-convolutional neural networks (1D-CNN) for real-time short-term voltage stability assessment (STVSA), which relies on a limited number of phasor measurement units (PMU) voltage samples. A two-stage STVSA application is proposed. The first stage comprises a 1D-CNN-based fast voltage collapse detector. The second stage comprises of 1D-CNN-based regressor to quantify the severity of the short-term voltage stability event. Two novel indices are presented, and their predicted future values are used to quantify the severity of short-term voltage stability events. This work also considers DB-SCAN clustering-based fault detection and physics-based fault localization for effective short-term voltage stability assessment and remedial actions by identifying the most critical PMUs. A bad data pre-processing technique is also included to mitigate the impact of missing data and outliers on short-term voltage stability assessment accuracy. The proposed framework is validated using the standard IEEE test systems and compared against other machine learning models to demonstrate the superiority of 1D-CNN-based time-series deep learning for short-term voltage stability assessment.

7 July 2023 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
AAArman Ahmed
Arman Ahmed
SBSagnik Basumallik
Sagnik Basumallik
AGAmir Gholami
Amir Gholami
SSSajan K. Sadanandan
Sajan K. Sadanandan
MNMohammad H. N. Namaki
Mohammad H. N. Namaki
YWYinghui Wu
Yinghui Wu
This work proposes a deep graph learning framework to identify, locate, and classify power, cyber, and cyber power events at the distribution system level. The proposed algorithm jointly exploits spatial, temporal, and node-level cyber and physical data features. The developed graph neural network, together with a deep autoencoder, utilizes physical measurements from distribution level phasor measurement units and cyber data from communication network logs. The spatial structure of the synchrophasor measurements and network is incorporated through a weighted adjacency matrix. The temporal structure is incorporated by defining a spatial operation in the gated recurrent unit. This spatio-temporal learning element resides inside a power event detection, localization, and classification module that provides the degree of confidence for an event label. To accurately pinpoint the location of an event to the nearest bus equipped with a measurement unit, a combination of squared error and proximity score is utilized. Also included is a cyber event detection module that employs heteroskedasticity to analyze the significance of various cyber features during different types of attacks. Finally, a dual-bit cyber-power decision table determines the nature of the event. The proposed method is validated on two distribution systems modeled in OPAL-RT/Hypersim with limited phasor measurement units for different possible physical and cyber events. Further analyses include comparison with other state-of-the-art methods and validation in the presence of measurement noise. Our method outperforms existing approaches and achieves an average detection accuracy of 97.97%, F1-score of 96.88%, precision of 96.53%, and recall of 98.57%.

14 June 2022 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
PSPartha S. Sarker
Partha S. Sarker
SSSajan K. Sadanandan
Sajan K. Sadanandan
ASAnurag Srivastava
Anurag Srivastava
The electric grid operation is constantly threatened with natural disasters and cyber intrusions. The introduction of Internet of Things (IoT)-based distributed energy resources (DERs) in the distribution system provides opportunities for flexible services to enable efficient, reliable, and resilient operation. At the same time, IoT-based DERs comes with cyber vulnerabilities and requires cyber-power resiliency analysis of the IoT-integrated distribution system. This work focuses on developing metrics for monitoring resiliency of the cyber-power distribution system, while maintaining consumers’ privacy. Here, resiliency refers to the system’s ability to keep providing energy to the critical load even with adverse events. In the developed cyber-power distribution system resiliency (DSR) metric, the IoT trustability score (ITS) considers the effects of IoTs using a neural network with federated learning. ITS and other factors impacting resiliency are integrated into a single metric using fuzzy multiple-criteria decision making (F-MCDM) to compute primary-level node resiliency (PNR). Finally, DSR is computed by aggregating PNR of all primary nodes and attributes of distribution level network topology and vulnerabilities utilizing game-theoretic data envelopment analysis (DEA)-based optimization. The developed metrics will be valuable for: 1) monitoring the DSR considering a holistic cyber-power model; 2) enabling data privacy by not utilizing the raw user data; and 3) enabling better decision making to select the best possible mitigation strategies toward resilient distribution system. The developed ITS, PNR, and DSR metrics have been validated using multiple case studies for the IoTs-integrated IEEE 123 node distribution system with satisfactory results.

11 September 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
VVVenkatesh Venkataramanan
Venkatesh Venkataramanan
PSPartha S. Sarker
Partha S. Sarker
KSK. Sadanandan Sajan
K. Sadanandan Sajan
ASAnurag Srivastava
Anurag Srivastava
AHAdam Hahn
Adam Hahn
With the ongoing automation driven by the push towards the smart electric grid and the advancement in associated cyberinfrastructure, the interaction between physical (transmission and distribution), cyber (communication, automation, control) and human (grid operators and decision-makers) is increasingly becoming more complex. An integrated testbed will help with resiliency analysis, where resiliency refers to the ability of the system to continue serving energy to the critical loads even with limited extreme contingencies. Testbeds using RT-simulators with multiple capabilities have been developed at different institutions. Still, no single existing testbed can offer full scalability while simultaneously meeting high fidelity requirements for resiliency experimentation. Co-simulating federated testbed assets can provide a scalable experimentation platform that can be leveraged for verification and validation. In this paper, an architecture is developed for federated cyber-physical testbed. A local federation with two real-time simulators is developed: Real-Time Digital Simulator (RTDS) and OPAL-RT have been interfaced using the VILLAS framework for end-to-end testing. Also, a real-time linear predictor is developed, and integrated here to address the communication latency impact on geographically allocated federated RT simulation. Lastly, resiliency analysis tools are formulated and utilized for T&D systems. As an illustrative use case, the resiliency of a T&D test system is simulated, and the results are analyzed. A 179 bus WECC transmission system is developed using OPAL-RT/ HYPERSIM, and a modified IEEE 13 node feeder system is modeled in RTDS/ RSCAD and interfaced for resiliency analysis.

13 October 2021 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
SRSyed Muhammad Hur Rizvi
Syed Muhammad Hur Rizvi
SSSajan K. Sadanandan
Sajan K. Sadanandan
ASAnurag Srivastava
Anurag Srivastava
Modeling load and voltage dependency can enhance the accuracy of system analysis (e.g., voltage control and situational awareness). Typically ZIP load model is used to model the voltage dependency of the load demand. With the recent widespread deployment of power electronics-based loads, traditional ZIP models are not suitable to model the voltage dependency of loads efficiently in smart distribution systems and microgrids. Power-electronics interfaced load demands the new voltage-dependent behavior models at the point of interconnection or at the aggregated level. This work develops a novel real-time parameter estimation algorithm for composite electronic-ZIP load models (CEZLM) using synchrophasor data. An adaptive window selection algorithm is proposed to extract estimation windows with almost constant load to voltage sensitivity. Estimation window extraction is followed by mode-sensitive parameter estimation for the CEZLM. A data pre-processing is developed using ensemble-based anomalous-data filtering and mitigation in the measurement stream. A cascade filter with a Kalman filter followed by a median filter is used to reduce the impact of noise. Two optimization algorithms: Constrained Least SQuares ( CLSQ ) and Sensitivity-Driven Constrained Optimization ( SDCO ) are proposed for tracking CEZLM parameters. CLSQ solves the constrained least-squares problem for parameter estimation and SDCO minimizes $L_{2}$ norm of a sensitivity-driven objective function with $L_{1}$ norm regularization to estimate CEZLM parameters. A T&D co-simulation framework is considered to demonstrate the performance of CEZLM parameter estimation for representative loads in a smart distribution system. Proposed algorithms have been validated using IEEE 30 bus system and 24-Bus 25kV distribution feeder with detailed CEZLM simulated using PSS/E and Hypersim real-time .