Will Meredith

Will Meredith

Auto-generated profile, based on publicly available information

Will Meredith

University of Nottingham

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2000 in Organic Geochemistry
Verified
Journal Article
Closed access
WMW Meredith
W Meredith
SKS.-J Kelland
S.-J Kelland
DJD.M Jones
D.M Jones

29 December 2000 in Analytical Chemistry
Verified
Journal Article
Closed access
DJD. M. Jones
D. M. Jones
JWJ. S. Watson
J. S. Watson
WMW. Meredith
W. Meredith
MCM. Chen
M. Chen
BBB. Bennett
B. Bennett

1 July 2009 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Open access
RGRachel Louise Gomes
Rachel Louise Gomes
WMWill Meredith
Will Meredith
CSColin E. Snape
Colin E. Snape
MSMark A. Sephton
Mark A. Sephton
Gas chromatography/mass spectrometry (GC/MS) is the preferred technique for the detection of urinary steroid androgens for drug testing in athletics. Excreted in either the glucuronide or sulfated conjugated form, steroids must first undergo deconjugation followed by derivatisation to render them suitable for GC analysis. Discussed herein are the deconjugation and the derivatisation preparative options. The analytical challenges surrounding these preparatory approaches, in particular the inability to cleave the sulfate moiety have led to a focus on testing protocols that reply on glucuronide conjugates. Other approaches which alleviate the need for deconjugation and derivatisation are also highlighted.

1 April 2009 in Quaternary Geochronology
Verified
Journal Article
Closed access
PAP.L. Ascough
P.L. Ascough
MBM.I. Bird
M.I. Bird
FBF. Brock
F. Brock
THT.F.G. Higham
T.F.G. Higham
WMW. Meredith
W. Meredith
CVChristopher Vane
Christopher Vane

1 May 2016 in Marine and Petroleum Geology
Verified
Journal Article
Closed access
CUClement N. Uguna
Clement N. Uguna
ACAndrew D. Carr
Andrew D. Carr
CSColin E. Snape
Colin E. Snape
WMWill Meredith
Will Meredith
ISIain C. Scotchman
Iain C. Scotchman
CVChristopher Vane
Christopher Vane

1 November 2012 in Geochimica et Cosmochimica Acta
Verified
Journal Article
Open access
WMW. Meredith
W. Meredith
PAP.L. Ascough
P.L. Ascough
MBMichael Bird
Michael Bird
DLD.J. Large
D.J. Large
CSC.E. Snape
C.E. Snape
ETE.L. Tilston
E.L. Tilston
A wide selection of thermal, chemical and optical methods have been proposed for the quantification of black carbon (BC) in environmental matrices, and the results to date differ markedly depending upon the method used. A new approach is hydropyrolysis (hypy), where pyrolysis assisted by high hydrogen pressures (150bar) facilitates the complete reductive removal of labile organic matter, so isolating a highly stable portion of the BC continuum (defined as BChypy). Here, the potential of hypy for the isolation and quantification of BC is evaluated using the 12 reference materials from the International BC Ring Trial, comprising BC-rich samples, BC-containing environmental matrices and BC-free potentially interfering materials. By varying the hypy operating conditions, it is demonstrated that lignocellulosic, humic and other labile organic carbon material (defined as non-BChypy) is fully removed by 550°C, with hydrogasification of the remaining BChypy not commencing until over 575°C. The resulting plateau in sample mass and carbon loss is apparent in all of the environmental samples, facilitating BC quantification in a wide range of materials. The BChypy contents for all 12 ring trial samples fall within the range reported in the BC inter-comparison study, and systematic differences with other methods are rationalised.All methods for BC isolation, including hypy are limited by the fact that BC cannot be distinguished from extremely thermally mature organic matter; for example in high rank coals. However, the data reported here indicates that BChypy has an atomic H/C ratio of less than 0.5 and therefore comprises a chemically well-defined polyaromatic structure in terms of the average size of peri-condensed aromatic clusters of >7 rings (24 carbon atoms), that is consistent across different sample matrices. This, together with the sound underlying rationale for the reductive removal of labile organic matter, makes hypy an ideal approach for matrix independent BC quantification. The hypy results are extremely reproducible, with BChypy determinations from triplicate analyses typically within ±2% across all samples, limited mainly by the precision of the elemental analyser