Mehmet Selçuk Uluer

Mehmet Selçuk Uluer

Auto-generated profile, based on publicly available information

Mehmet Selçuk Uluer

Department of Anesthesiology, School of Medicine, Selçuk University, Konya, Türkiye

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2019 in Sao Paulo Medical Journal
Verified
Journal Article
Open access
PDF file
MSMehmet SARGIN
Mehmet SARGIN
MUMehmet Selçuk Uluer
Mehmet Selçuk Uluer
BŞBarış Şimşek
Barış Şimşek
KEY WORDS: Consciousness monitors; Cognition; Conscious sedation; Colonoscopy

9 July 2018 in Turkish Journal of Anesthesia and Reanimation
Verified
Journal Article
Closed access
MSMehmet SARGIN
Mehmet SARGIN
HSHalil Samancioglu
Halil Samancioglu
MUMehmet Selcuk Uluer
Mehmet Selcuk Uluer
Scalp block has become a frequently used technique with an increasing number of indications today. Despite the many advantages of the scalp block, certain rare complications have been identified. It should be remembered that although it is a relatively safe procedure, it may lead to the development of facial nerve palsy. In this article, we present a case of transient facial nerve palsy developed after the scalp block that was used to drain the subdural hematoma with a burr hole.

1 February 2017 in Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
Verified
Journal Article
Closed access
MSMehmet SARGIN
Mehmet SARGIN
MUMehmet Selçuk Uluer
Mehmet Selçuk Uluer
SÖSadik Özmen
Sadik Özmen
Although positive end-expiratory pressure (PEEP) is commonly used to improve respiratory mechanics and oxygenation during pneumoperitoneum (PP), the effect of PEEP on cerebral homeostasis during carbon dioxide PP remains uncertain. This study investigated the changes in regional cerebral oxygen saturation (rSO2) associated with 0, 5, and 10 cm H2O PEEP during PP while undergoing laparoscopic cholecystectomy under sevoflurane anesthesia. In total, 105 patients between the ages of 18 to 60 years, scheduled to undergo laparoscopic cholecystectomy under general anesthesia, were studied. The patients were randomized, into 3 groups: group I (n=35) with no external PEEP, group II (n=35) with external PEEP of 5 cm H2O, group III (n=35) with external PEEP of 10 cm H2O. Heart rate, mean blood pressure, oxygen saturation, and rSO2 values were continuously recorded from awake status to tracheal extubation. The measurements of hemodynamic parameters were statistically similar between 3 groups (P>0.05). rSO2 values were statistically similar between 3 groups (P>0.05). We consider that both 5 and 10 cm H2O PEEP levels can be safely used during PP applied during laparoscopic surgery, without affecting hemodynamics, and without causing a decline in rSO2.

31 January 2023 in Anesthesia and Pain Medicine
Verified
Journal Article
Open access
PDF file
MSMehmet SARGIN
Mehmet SARGIN
MUMehmet Selçuk Uluer
Mehmet Selçuk Uluer
Background: Changes in tissue oxygen saturation determined by near-infrared spectroscopy (NIRS) may help predict and determine the success of a lateral infraclavicular (LIC) block. We investigated whether evaluation of tissue oxygen saturation determined by NIRS could be an indicator of LIC block success.Methods: Forty patients scheduled for hand or forearm surgery under LIC block were studied. NIRS sensors were placed on the ventral aspect of both mid-forearms, and the contralateral hand was used as the control group. NIRS values were recorded before the block and at regular intervals during the following 30 min.Results: NIRS values were significantly higher in the successfully blocked patients when compared to the complete failure, partial failure, and contralateral hand groups at the 10th min. In the successfully blocked patients, NIRS values (mean ± SD [change in %]) increased by 11.09 ± 4.86 (16.03%), 15.00 ± 4.53 (21.76%), 16.35 ± 5.14 (23.77%), 16.38 ± 4.88 (23.85%), 16.67 ± 5.04 (24.29%), and 16.96 ± 5.71 (24.78%), respectively, from baseline to 5, 10, 15, 20, 25, and 30 min. ΔTs values were significantly higher in the successfully blocked patients than in the complete failure patients and contralateral hand at the 30th min. However, there was no statistically significant difference when comparing ΔTs values of successful block and partial failure block patients at the 30th min.Conclusions: We conclude that measurement of tissue oxygen saturation by NIRS within the scope of evaluation of the lateral infraclavicular block is a rapid, effective, and applicable technique.

1 January 2022 in TURKISH JOURNAL OF MEDICAL SCIENCES
Verified
Journal Article
Open access
PDF file
FÇFaruk Çi̇çEkci̇
Faruk Çi̇çEkci̇
MUMehmet Selçuk Uluer
Mehmet Selçuk Uluer
MSMehmet SARGIN
Mehmet SARGIN
EAEmine ASLANLAR
Emine ASLANLAR
IKİnCi̇ Kara
İnCi̇ Kara
MKMuslu Kazım Körez
Muslu Kazım Körez
Background/aim: This study was designed to observe and compare the performance of fiberoptic laryngeal (FOL) view, leakage test (LT) and ultrasonography (USG) usage in detecting i-gel position in pediatric patients. Materials and methods: One hundred ten consecutive children were included in this single-armed prospective observational study. After anesthetic induction, i-gel placement confirmed using FOL and LT was evaluated using USG in three planes. According to our scoring system, acceptable and unacceptable grades (FOL, LT and USG) were determined to describe placement. Sensitivity and specificity were determined by comparing USG performance with the other two tests. Results: Ultrasonography was found a sensitivity of 20% positive predictive value (PPV) for unacceptable i-gel placement according to FOL grade and a sensitivity of 37.04% with a 100% PPV according to LT grade. USG was found a specificity of 91.84% negative predictive value (NPV) of 91.84% for acceptable i-gel placement according to FOL grade and the NPV specificity of 100% with a 82.65% NPV according to LT grade. Conclusion: Ultrasonography demonstrated a very good diagnostic performance in the detection of optimal i-gel placement according to both FOL and LT. However, both FOL and LT showed poor diagnostic performance compared to USG in demonstrating i-gel malposition.

9 May 2023 in Cyprus Journal of Medical Sciences
Verified
Journal Article
Closed access
FÇFaruk Çiçekci
Faruk Çiçekci
MUMehmet Selçuk Uluer
Mehmet Selçuk Uluer
MSMehmet SARGIN
Mehmet SARGIN
EAEmine ASLANLAR
Emine ASLANLAR
PŞPerihan Şener
Perihan Şener
IKİnci Kara
İnci Kara