Yuming Gao

Yuming Gao

Auto-generated profile, based on publicly available information

Yuming Gao

School of Mechanical Engineering, Shandong University of Technology, Zibo, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2023 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
ZYzhang lu yang
zhang lu yang
YGYuming Gao
Yuming Gao
ZMZonggao Mu
Zonggao Mu
LYLei Yan
Lei Yan
ZLZixuan Li
Zixuan Li
MGMingwang Gao
Mingwang Gao
In order to realize the flexible capture of noncooperative targets, a variable-stiffness planning method considering both the overall configuration and cable tension for a hyper-redundant manipulator is proposed in this article. First, combining its kinematics and statics, an analytical stiffness model of the hyper-redundant manipulator is developed to evaluate its stiffness. The overall configuration and cable tension of the hyper-redundant manipulator are both identified as main factors that affect the stiffness. Then, a concept of configuration-stiffness mesh and tension-stiffness mesh is proposed to characterize the stiffness trend which can be optimized by active control points. On one hand, the gradient projection method is used to change the overall configuration of the hyper-redundant manipulator to optimize its stiffness. On the other hand, the cascade proportional integral differential control law is used to change the cable tension of the hyper-redundant manipulator to optimize its stiffness. Finally, simulations and experiments are carried out to validate the analytical stiffness model and variable-stiffness planning method considering both the overall configuration and cable tension for hyper-redundant manipulators.

11 June 2024 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
ZMZonggao Mu
Zonggao Mu
YGYuming Gao
Yuming Gao
WLWeitao Li
Weitao Li
GLGuikun Lv
Guikun Lv
SZShun Zhao
Shun Zhao
RDRuichun Dong
Ruichun Dong
Owing to the flexibility and redundancy, concentric cable-driven manipulators are widely used in confined space applications. However, it is challenging to establish shape prediction or force sensing for this type of manipulator. This paper proposes a static modeling method to address the shape prediction or force sensing challenges of concentric cable-driven manipulators. The Newton–Euler method is adopted to establish the static model of the concentric cable-driven manipulator with consideration of friction. On the one hand, the static model can accurately predict the shape when the external load and cable tension of the concentric cable-driven manipulator are known. On the other hand, the static model can also assist force sensing when the cable tension and shape of the concentric cable-driven manipulator are known. Finally, the accuracy of the shape prediction and force sensing of this model are both verified by experiment, separately. The results show that the accuracy of shape prediction is 95% and the accuracy of force sensing is 90%. The model is thus suitable for the shape prediction or force sensing of the concentric cable-driven manipulator. In addition, the errors associated with shape prediction or force sensing were found to be significantly reduced when the influence of friction was taken into account. Therefore, the proposed static modeling method considering friction is effective for the shape prediction or force sensing of concentric cable-driven manipulators. Note to Practitioners —Concentric cable-driven manipulators featured by small size and high flexibility are excellent candidates for operations in confined environments. This paper proposes a static modeling method to address the shape prediction or force sensing challenges of concentric cable-driven manipulators. The shape prediction can be used to facilitate the accurate positioning and control of such manipulators in various situations. The force sensing can be used to avoid unnecessary harm within the working environment of such manipulators. It is beneficial to promote the application of such manipulators in minimally invasive surgery, pharyngeal swab sampling, and other fields. Moreover, the static method applies not only to the specific model of a concentric cable-driven manipulator but also to various cable-driven manipulators. Similarly, the importance of the static model is not only that it improves the accuracy of shape prediction or force sensing but also that it can be applied to automation control of motion, flexibility, and stiffness.

12 June 2024 in IEEE Transactions on Systems, Man, and Cybernetics: Systems
Verified
Journal Article
Closed access
YGYuming Gao
Yuming Gao
GLGuikun Lv
Guikun Lv
SZShun Zhao
Shun Zhao
NDNing DING
Ning DING
ZMZonggao Mu
Zonggao Mu
The concentric cable-driven manipulator (CCDM) has the characteristics of high dexterity, light weight, and safe movement, making them widely used in confined spaces. However, there are difficulties in the fine control with proper stiffness of CCDMs due to their flexible structures and various configurations. This article proposes an analytical variable-stiffness method for the fine control of CCDMs. First, the stiffness model is established by taking into account key factors, including the middle elastic backbone, cable tensions, configurations, and external loads. Then, the stiffness mesh is generated based on the stiffness model, which visually represents changing trends of its stiffness. Simultaneously, the stiffness of CCDMs can be accurately adjusted by optimizing their configurations and cable tensions. Therefore, the fine control with high or low stiffness of CCDMs can be realized in practical applications. Finally, experiments are conducted to verify the analytical variable-stiffness method of CCDMs. Results indicate that the average error of the stiffness model is 5.42%. It also confirms the effectiveness of the proposed method for achieving analytical variable-stiffness control of CCDMs. Furthermore, the proposed method is also applicable to cable-driven manipulators with similar structures.

4 March 2024 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
YGYuming Gao
Yuming Gao
CWChengjiang Wang
Chengjiang Wang
LJLihui Jia
Lihui Jia
HLHao Lv
Hao Lv
GLGuikun Lv
Guikun Lv
ZMZonggao Mu
Zonggao Mu
A biarc fitting algorithm is proposed for the designed concentric cable-driven manipulator working in oropharyngeal (OP) swab samplings. This algorithm makes the concentric cable-driven manipulator composed of discrete nodes have a high degree of fit with the continuous curve planned by the biarc method. Three advantages of this algorithm are as follows. First of all, by adjusting the tangent at the end point, the problem of large deviation fitting between the actual path and the planned path caused by the fixed tangent at the end point during path tracking is solved. In addition, by adjusting the given starting point, the problem of large deviation fitting between the concentric cable-driven manipulator and biarc curve caused by non-integer number of nodes during configuration fitting is solved. Further, by adjusting the proportionality coefficient, the problem of large deviation fitting between the concentric cable-driven manipulator and biarc curve caused by the odd-even variation of the number of moving nodes during configuration fitting is solved. Tracking the planned paths of OP-swab sampling, the simulation and experiment verify the effectiveness of the biarc fitting algorithm for concentric cable-driven manipulators working in OP-swab samplings. Note to Practitioners —This paper is motivated by the requirement of effective planning for a concentric cable-driven manipulator composed of discrete nodes working in automatic oropharyngeal-swab samplings. Existing planning methods make it difficult to fit a concentric cable-driven manipulators composed of discrete nodes to the planned continuous curve. In this paper, we propose a biarc fitting algorithm to improve the degree of fit between cable-driven manipulator composed of discrete nodes and the planned continuous curve. This algorithm makes the concentric cable-driven manipulator composed of discrete nodes have a high degree of fit with the continuous curve planned by the biarc method. Three key factors of this algorithm to be optimized are the tangent at the end point, given starting point and proportionality coefficient. The simulation and experiment verify the effectiveness of the biarc fitting algorithm. In the future work, we will study the modelling based on variable-stiffness control and force feedback control of concentric cable-driven manipulators. This method can be used not only for concentric cable-driven manipulators working in the medical field, but also for cable-driven manipulators composed of discrete nodes inspecting and maintaining in aerospace, nuclear power plant and other similar fields.