Redouane Fodil

Redouane Fodil

Auto-generated profile, based on publicly available information

Redouane Fodil

INSERM, U955 IMRB, “Biology of the Neuromuscular System” Team, Univ Paris-Est Créteil, Créteil, France

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2002 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
VLVale´rie M. Laurent
Vale´rie M. Laurent
SHSylvie He´non
Sylvie He´non
EPEmmanuelle Planus
Emmanuelle Planus
RFRedouane Fodil
Redouane Fodil
MBMartial Balland
Martial Balland
FGFranc¸oIs Gallet
Franc¸oIs Gallet
We compare the measurements of viscoelastic properties of adherent alveolar epithelial cells by two micromanipulation techniques: (i) magnetic twisting cytometry and (ii) optical tweezers, using microbeads of same size and similarly attached to F-actin. The values of equivalent Young modulus E, derived from linear viscoelasticity theory, become consistent when the degree of bead immersion in the cell is taken into account. E-values are smaller in (i) than in (ii): ∼34–58 Pa vs ∼29–258 Pa, probably because higher stress in (i) reinforces nonlinearity and cellular plasticity. Otherwise, similar relaxation time constants, around 2 s, suggest similar dissipative mechanisms.

21 April 2006 in Cell Motility
Verified
Journal Article
Closed access
PDF file
Sophie FéréolSophie Féréol
Sophie Féréol
RFRedouane Fodil
Redouane Fodil
BLBéatrice Labat
Béatrice Labat
SGStéphane Galiacy
Stéphane Galiacy
VLValérie M. Laurent
Valérie M. Laurent
EPEmmanuelle Planus
Emmanuelle Planus

1 April 2000 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
SJSamir Jaber
Samir Jaber
RFRedouane Fodil
Redouane Fodil
ACAnnalisa Carlucci
Annalisa Carlucci
MBMOHAMED BOUSSARSAR
MOHAMED BOUSSARSAR
JPJérôme Pigeot
Jérôme Pigeot
LBLaurent Brochard
Laurent Brochard
The use of helium–oxygen (HeO2) was tested in combination with noninvasive ventilation (NIV) in 10 patients with acute exacerbation of chronic obstructive pulmonary disease (COPD). Effort to breathe as assessed by the respiratory muscle pressure-time index (PTI), work of breathing (WOB), and gas exchange were the main endpoints. Results of NIV-HeO2 were compared with those obtained with standard NIV (AirO2), at two levels of pressure-support ventilation (PSV), 9 ± 2 cm H2O and 18 ± 3 cm H2O. Significant reductions in PTI were observed between HeO2 and AirO2 at both the low PSV level (n = 9; 160 ± 58 versus 198 ± 78 cm H2O/s/ min; p < 0.05) and the high PSV level (n = 10; 100 ± 45 versus 150 ± 82 cm H2O/s/min; p < 0.01). WOB also differed significantly between HeO2 and AirO2 (7.8 ± 4.1 versus 10.9 ± 6.1 J/min at the low PSV level, p < 0.05; and 5.7 ± 3.3 versus 9.2 ± 5. J/min, p < 0.01 at the high PSV level). HeO2 reduced PaCO2 at both the low PSV level (61 ± 13 versus 64 ± 15 mm Hg; p < 0.05) and the high PSV level (56 ± 13 versus 58 ± 14 mm Hg; p < 0.05), without significantly changing breathing pattern or oxygenation. We conclude that use of HeO2 during NIV markedly enhances the ability of NIV to reduce patient effort and to improve gas exchange.

5 May 2006 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
CCCéline Croce
Céline Croce
RFRedouane Fodil
Redouane Fodil
MDMarc Durand
Marc Durand
GSGabriela Sbirlea-Apiou
Gabriela Sbirlea-Apiou
GCGeorges Caillibotte
Georges Caillibotte
BLBruno Louis
Bruno Louis

1 May 2007 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
LRLudovic de Rochefort
Ludovic de Rochefort
LVLaurence Vial
Laurence Vial
RFRedouane Fodil
Redouane Fodil
XMXavier Maître
Xavier Maître
BLBruno Louis
Bruno Louis
GSGabriela Sbirlea-Apiou
Gabriela Sbirlea-Apiou
Computational fluid dynamics (CFD) and magnetic resonance (MR) gas velocimetry were concurrently performed to study airflow in the same model of human proximal airways. Realistic in vivo-based human airway geometry was segmented from thoracic computed tomography. The three-dimensional numerical description of the airways was used for both generation of a physical airway model using rapid prototyping and mesh generation for CFD simulations. Steady laminar inspiratory experiments (Reynolds number Re = 770) were performed and velocity maps down to the fourth airway generation were extracted from a new velocity mapping technique based on MR velocimetry using hyperpolarized3He gas. Full two-dimensional maps of the velocity vector were measured within a few seconds. Numerical simulations were carried out with the experimental flow conditions, and the two sets of data were compared between the two modalities. Flow distributions agreed within 3%. Main and secondary flow velocity intensities were similar, as were velocity convective patterns. This work demonstrates that experimental and numerical gas velocity data can be obtained and compared in the same complex airway geometry. Experiments validated the simulation platform that integrates patient-specific airway reconstruction process from in vivo thoracic scans and velocity field calculation with CFD, hence allowing the results of this numerical tool to be used with confidence in potential clinical applications for lung characterization. Finally, this combined numerical and experimental approach of flow assessment in realistic in vivo-based human airway geometries confirmed the strong dependence of airway flow patterns on local and global geometrical factors, which could contribute to gas mixing.

4 November 2014 in Respiratory Care
Verified
Journal Article
Closed access
PDF file
PDPierre-Eric Danin
Pierre-Eric Danin
EGEmmanuelle Girou
Emmanuelle Girou
PLPatrick Legrand
Patrick Legrand
BLBruno Louis
Bruno Louis
RFRedouane Fodil
Redouane Fodil
LBLaurent Brochard
Laurent Brochard
BACKGROUND: A biofilm is found on the inner side of endotracheal tubes (ETT) in mechanically ventilated patients, but its features and role in pneumonia remain unclear. METHODS: This prospective, observational, monocentric study included critically ill ventilated subjects. Measurement of the ETT inner volume was first performed before extubation using the acoustic reflection method. After extubation, the biofilm was studied by means of optical and atomic force microscopy. Bacteriological analysis was then performed and compared with clinical documentation. RESULTS: Twenty-four subjects were included. Duration of intubation lasted from 2 to 79 d (mean ± SD: 11 ± 15 d). The mean percentage of ETT volume loss evaluated in situ ( n = 21) was 7.1% and was not linked with the duration of intubation. Analyses with atomic force microscopy ( n = 6) showed a full coverage of the inner part of the tube with biofilm, even after saline rinse. Its thickness ranged from 0.8 to 5 μm. Bacteriological cultures of the biofilm ( n = 22) often showed the same bacteria as in tracheal secretions, especially for pathogenic organisms. Pseudomonas aeruginosa and Candida albicans were among the most frequent microorganisms. In subjects who had experienced a successfully treated episode of ventilator-associated pneumonia ( n = 5), the responsible bacteria were still present in the biofilm. CONCLUSIONS: ETT biofilm is always present in intubated patients whatever the duration of intubation and appears quickly after intubation. Even after soft rinse, a small but measurable part of biofilm remains always present, and seems strongly adherent to the ETT lumen. It contains potentially pathogenic bacteria for the lung.