Jashandeep Singh

Jashandeep Singh

Auto-generated profile, based on publicly available information

Jashandeep Singh

Bhai Gurdas Polytechnic College, Sangrur, Punjab, India

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
MSMahavir Singh
Mahavir Singh
VJVishavdeep Jindal
Vishavdeep Jindal
JSJashandeep Singh
Jashandeep Singh
The paper aims to investigate the long-term behavior of insulating oil in high-voltage applications by analyzing and correlating the changes in its physicochemical properties over the high-temperature range. To comprehend the rate of oil degradation, uninhibited mineral oil (MO), blended oil (MSO), and synthetic ester (SE) have been exposed to enhanced thermal stresses in combination with solid insulation. In compliance with IEEE C57.100, a five-point aging mechanism for thermal aging was taken into account. Thermal stresses ranging from 100 to 195 °C were applied continuously for 168 hours with a temperature variation of 25 °C. The effects of thermal stress have been deliberated by analyzing changes in physicochemical properties, such as density, kinematic viscosity, acidity, flash point, and visual observation of the mineral oil, synthetic ester, and mixed oil. The results demonstrated that the inclusion of esters into mineral oil enhances its characteristics and functionality and accentuates its suitability for assessing the state of high-voltage transformers.

22 August 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
KKKulraj Kaur
Kulraj Kaur
DBDeepika Bhalla
Deepika Bhalla
JSJashandeep Singh
Jashandeep Singh
Traditional dissolved gas analysis (DGA) methods for incipient fault diagnosis of oil immersed power transformers often give contradictory results. Due to the increased availability of methods, and procedures for fault diagnosis a reliable method is needed to reach a conclusion. The certainty factor (CF) method gives promising results where the available knowledge base and techniques are unable to arrive at the same conclusion. In this work, a traditional method based on a gas ratio method, two graphical methods, and a key gas (KG) method are applied to DGA samples. When the fault diagnosis by the traditional methods is contradictory, a computational method based on evidence and CF is used. The combined certainty factor (CCF) is applied to the CF results incrementally for confirming fault type. There is a special provision for partial discharge (PD) type of fault. The proposed method is checked on samples used in literature where the actual fault is known. The goal is to make available a reliable method that scientifically combines the diagnosis of three traditional DGA methods and confirms with an increased level of responsibility the diagnosis of the type of incipient fault. The proposed method may be used by utilities to reach a common consensus in case of contradictory diagnosis by traditional DGA methods.

22 January 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
KKKulraj Kaur
Kulraj Kaur
DBDeepika Bhalla
Deepika Bhalla
JSJashandeep Singh
Jashandeep Singh
Transformer is among the key equipment of electrical power system for maintaining the continuity of transmission and distribution of power. Dissolved gas analysis (DGA) methods are accepted by utilities for condition monitoring and detecting incipient faults in transformers. The graphical DGA methods have gained popularity in the recent past. The three-gas and five-gas based graphical methods are regularly used and recently seven-gas and four-gas methods have been proposed. This work is based on six gases and a Hexagon method (HexM) is proposed. The HexM is tested for the IECTC 10 database for detection of six types of faults. None of the graphical methods proposed so far have a region defined for normal condition. In this method a region in the hexagon is earmarked for normal ageing, and samples from the published literature are used for testing it. The results of HexM are compared with generally used Duvals triangles and pentagons and the recently proposed heptagon method for fault type interpretation. The suggested technique is tested and compared with graphical methods. Based on the test samples, the Hexagon figure gives 93.6 % accuracy, Heptagon gives 84.9% accuracy.

1 March 2022 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
KKKulraj Kaur
Kulraj Kaur
DBDeepika Bhalla
Deepika Bhalla
JSJashandeep Singh
Jashandeep Singh
Power transformer is considered important equipment both in the transmission and distribution zone of electric power. Safety of power system elements plays a crucial role for enhancing its reliability. Transformer being a major component plays a much vital role and needs to be monitored and maintained at a regular basis. Transformer oil helps in performing the functions of insulation, cooling and helps extinguish arcs. Transformer oil also dissolves the gases which get generated by the degradation of oil, presence of moisture and gas from insulation deterioration of cellulose, gases and moisture from the surrounding, to which the oil is exposed. The dissolved gas present in an oil sample can be helpful in determining the nature of a fault which can vary according to gas types and its concentrations. DGA (Dissolved Gas Analysis) have been used as a suitable tool in enabling the reliability of the system and safety of the transformer for a long time. An analysis of Dissolved gases in oil is analytical method and have been used and interpreted differently by different methods and users. DGA methods using ratios, gas concentration and graphical methods have been presented in this work. The tools use mix of fuzzy based analysis, MATLAB. The basic motivation of the work is to create a platform for DGA analysis so as to provide early and easy detection and diagnosis of Transformer Failures.