1 August 2000 in Journal of Biomechanics
1 October 2001 in Journal of Biomechanics
22 January 2003 in Journal of Magnetic Resonance Imaging
PPPanorea Papathanasopoulou
Panorea Papathanasopoulou
+2
Purpose: To study pulsatile fluid flow in a physiologically realistic model of the human carotid bifurcation, and to derive wall shear stress (WSS) vectors.Materials and Methods: WSS vectors were calculated from time‐resolved 3D phase‐contrast (PC) MRI measurements of the velocity field. The technique was first validated with sinusoidal flow in a straight tube, and then used in a model of a healthy human carotid bifurcation. Velocity measurements in the inflow and outflow regions were also used as boundary conditions for computational fluid dynamics (CFD) calculations of WSS, which were compared with those derived from MRI alone.Results: The straight tube measurements gave WSS results that were within 15% of the theoretical value. WSS results for the phantom showed the main features expected from fluid dynamics, notably the low values in the bulb region of the internal carotid artery, with a return to ordered flow further downstream. MRI was not able to detect the high WSS values along the divider wall that were predicted by the CFD model. Otherwise, there was good general agreement between MRI and CFD.Conclusion: This is the first report of time‐resolved WSS vectors estimated from 3D‐MRI data. The technique worked well except in regions of disturbed flow, where the combination with CFD modeling is clearly advantageous. J. Magn. Reson. Imaging 2003;17:153–162.
31 December 1996 in Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences
In this study, magnetic resonance imaging techniques have been used to examine the geometry of arterial curvature and branching in casts and in vivo, and to measure the distribution of axial velocity in the associated flow. It is found, contrary to a widely held view, that the geometry is commonly non-planar. Moreover, relatively small values of the parameters which render the geometry non-planar appear significantly to affect the velocity distribution. The findings suggest that non-planarity is an important factor influencing arterial flows, including wall shear. The implications are not restricted to vascular biology, pathology and surgery, but may extend to the design of general piping systems.
1 February 2013 in Journal of Biomechanical Engineering
Stimulated by a recent controversy regarding pressure drops predicted in a giant aneurysm with a proximal stenosis, the present study sought to assess variability in the prediction of pressures and flow by a wide variety of research groups. In phase I, lumen geometry, flow rates, and fluid properties were specified, leaving each research group to choose their solver, discretization, and solution strategies. Variability was assessed by having each group interpolate their results onto a standardized mesh and centerline. For phase II, a physical model of the geometry was constructed, from which pressure and flow rates were measured. Groups repeated their simulations using a geometry reconstructed from a micro-computed tomography (CT) scan of the physical model with the measured flow rates and fluid properties. Phase I results from 25 groups demonstrated remarkable consistency in the pressure patterns, with the majority predicting peak systolic pressure drops within 8% of each other. Aneurysm sac flow patterns were more variable with only a few groups reporting peak systolic flow instabilities owing to their use of high temporal resolutions. Variability for phase II was comparable, and the median predicted pressure drops were within a few millimeters of mercury of the measured values but only after accounting for submillimeter errors in the reconstruction of the life-sized flow model from micro-CT. In summary, pressure can be predicted with consistency by CFD across a wide range of solvers and solution strategies, but this may not hold true for specific flow patterns or derived quantities. Future challenges are needed and should focus on hemodynamic quantities thought to be of clinical interest.
1 October 2002 in Journal of Biomechanics