The sources of dust on the territory of Ruse region, Bulgaria are industry, transport and domestic heating by solid fuel. PM10 (particulate matter with a diameter between 2.5 and 10 μm) levels for Ruse mark a significant increase during the autumn-winter period compared to the levels during the spring-summer period [1]. Obviously there is a relationship between PM10 contamination levels and ambient air temperature. The lower the temperatures are, the higher the PM10 levels are. The biggest peak of PM10 levels for the autumn-winter period is usually observed in January months. It is in January that the number of days in which there is exceedance of the limit values of the PM10 levels is maximum observed. Also in January months the day and night temperatures are the lowest and usually they do not pass 0°C for many days of the month. To understand better this relationship we provide a statistical analysis of ambient air PM10 contamination during winter periods. Correlations between the measured PM10 values and the respective temperatures measured for January months for different years are presented. Descriptive statistics of PM10 and some atmospheric characteristics as well as linear regression analysis are calculated and commented in the paper.
This paper is devoted to examine the PM10 and PM2.5 pollution in Ruse region, Bulgaria. It is a continuation of our previous work [1] where we presented a statistical analysis and modelling of the level of PM10 air pollution in Ruse using data from one of two monitoring stations (station 2) in the city. Now in this paper we present statistical analysis of the level of PM10 pollutant on the basis of data from the another monitoring station (station 1). The measurements cover the period since 2015 up to now. The results from analysis and modelling of PM2.5 air pollutant are also presented and commented in the paper.
Mathematical modeling of the heat transfer during the pyrolysis process used for the treatment of the End-of-Lifetires (EOLT) is presented in this paper. The pyrolysis process is 3D and non-stationary and because of this it is very complicated for modeling and studying. To simplify the modeling here a hierarchy of 2D models for the temperature which describe the non-stationary heat transfer in such a pyrolysis station is created. An algorithm for solving the model equations, based on MATLAB software is developed. The results for the temperature for some characteristic periods of operation of pyrolysis station are presented and commented in the paper. The results from this modeling can be used in the real pyrolysis station for more precise displacement of measurement devices and for designing of automated management of the process.
Temperature, air humidity and atmospheric pressure measurements in Ruse region for 40 years period are statistically studied in this paper. Descriptive statistics, Pearson correlation coefficients and linear regression models for these characteristics are presented and commented. The most variable atmospheric parameter is air humidity during the spring seasons. The hardest change of temperature and atmospheric pressure is during January. Temperature has biggest change in January and smallest - in July. Humidity has biggest change in April and smallest - in October. Atmospheric pressure has biggest change in January and smallest - in July. Characteristics temperature and atmospheric pressure of spring (April) and autumn (October) are very similar. Summer temperatures and atmospheric pressure (July) have smallest change. The atmospheric temperature data for Ruse region are also compared with the official basic data for Bulgaria. It is shown that mean values of the temperature in Ruse region are bigger than the mean temperature for Bulgaria. It is shown that the winter and spring temperatures for Ruse region are slightly going up lately which could be connected with the typical for Ruse region air pollution especially by particle matter.
One of the most dangerous waste in the world are the End-of-Life tires (EOLT). They are waste that does not practically decompose in nature. Because of this their sound treatment is needed for environment protection. Pyrolysis process is one of the possible methods for such a treatment. Globally, around 23% of all EOLT are processed through pyrolysis, whereas in the Republic of Bulgaria only 5% are processed by pyrolysis. It is clear that for Bulgaria this method still has a good potential for usage, development and further research. The pyrolysis process, used for EOLT treatment, usually is 3D and non-stationary. Thus it is very complicated for modeling and studying. Following [3] an adequate mathematical model of the heat transfer during the pyrolysis process used for the treatment of the End-of-Life tires (EOLT) has been presented in our previous paper [1]. There a numerical algorithm in MATLAB for solving the respective mathematical initial and boundary value problems has been also developed. Some results for the temperature field for several characteristic periods of operation of pyrolysis station are presented and commented in this paper [1]. In our next paper [2] we have examined the influence of the heating upon the heat transfer during the pyrolysis process used for EOLT treatment. This paper deals with studying the influence of the heater position upon the heat transfer during EOLT treatment by pyrolysis process. The results for temperature fields, temperature isolines and gradients at some specific moments of time and for two different initial heating functions are graphically presented and commented. Results from this modeling can be used in the real pyrolysis stations for more precise displacement of heathers and measurement devices and for designing of automated management of the process.